Transformeer je huis met de nieuwste multi-elektronica oplossingen, van intelligente verlichting tot spraakgestuurde apparaten, allemaal ontworpen om het leven gemakkelijker, veiliger en meer verbonden te maken.
SKU:VFD485VP43AFTHA
Delta VFD485VP43AFTHA | 3-Phase 460V 91A Drive
Manufacturer: Delta
Product No.: VFD485VP43AFTHA
Product Type: AC Drive
Product Origin: CN
Payment:T/T, Western Union
Weight: 8000g
Shipping port: Xiamen
Warranty: 12 months
Delen
- Snelle levering
- 24/7 Ondersteuning
- Kwaliteitsborging
Beschrijving
Product Overview
The Delta VFD485VP43AFTHA is a high-capacity Variable Frequency Drive (VFD) engineered for heavy-duty industrial fluid control. With a robust output of 45kW (60HP), this drive excels in managing large-scale HVAC systems, water treatment pumps, and industrial cooling towers. This specific "THA" variant incorporates enhanced thermal management and an integrated DC reactor to suppress harmonic distortion, ensuring compliance with strict power quality standards. Its advanced Sensorless Vector Control (SVC) provides the perfect balance between high starting torque and energy-efficient cruise speeds.
Technical Configuration
Model Specification Logic
- Power Rating (485): Delivers a rated output current of 91 Amps, supporting motors up to 45kW (60HP).
- Series (VP): Specialized for variable torque loads, offering a multi-pump control mode and fire mode for emergency fan operation.
- Voltage Class (43): 460V 3-Phase input (compatible with 380V–480V ±10% utility grids).
- Filter & Reactor (AF): Includes a built-in EMC filter (Class A) and an internal DC reactor to reduce THDi (Total Harmonic Distortion).
- Frame Configuration (THA): Features a reinforced chassis with an independent cooling duct design to isolate power components from dust.
Technical Specifications
| Parameter | Data Value Details |
|---|---|
| Rated Output Current | 91 A (Normal Duty) |
| Applicable Motor Output | 45 kW / 60 HP |
| Input Current | 86 A (3-Phase AC) |
| Braking Torque | Approx. 20% (Standard); up to 125% with external unit |
| Starting Torque | 150% at 0.5Hz (SVC mode) |
| Frequency Stability | Digital: ±0.01%; Analog: ±0.2% |
| Efficiency | ≥ 97.5% at rated load |
| Enclosure Rating | IP20 (Standard) / NEMA 1 Optional |
Installation & Maintenance Guide
High-Power Engineering Standards
Power Quality: The integrated DC reactor in the VFD485VP43AFTHA significantly reduces harmonics. No additional line reactor is required unless the power source impedance is less than 3%. This reduces both installation footprint and overall system cost.
Cooling Architecture: This model utilizes an isolated cooling duct. When mounting in a cabinet, ensure the exhaust air is vented directly out of the enclosure to prevent internal heat buildup. The drive’s fans are field-replaceable to ensure long-term uptime.
Torque Terminal Torque: For the 91A output terminals, use M6 or M8 ring terminals with a tightening torque of 4.0-5.0 N-m to prevent hot spots caused by loose electrical connections.
Engineering Advantages
The VFD485VP43AFTHA features an Advanced Multi-Pump Control logic, capable of managing up to 4 pumps simultaneously (1 master fixed speed + 3 auxiliary). It includes a built-in RS-485 interface supporting Modbus RTU/ASCII with speeds up to 38.4kbps. Its 4-layer conformal coating protects the 45kW power bridge and control logic from moisture and chemical vapors, making it suitable for wastewater treatment facilities and chemical processing plants.
Technical FAQs
Q1: What is the maximum carrier frequency for this 45kW model?
A1: The carrier frequency can be set between 2kHz and 10kHz. For a 45kW drive, 4kHz is the recommended default to balance switching losses and acoustic motor noise.
Q2: Can I run this drive on a single-phase supply for testing?
A2: No. High-power VP series drives require a balanced 3-phase input to prevent phase-loss protection trips and potential damage to the input rectifier bridge.
Q3: How does the "Fire Mode" work in this drive?
A3: When activated via a digital input, the VFD ignores non-critical alarms and runs at a preset frequency to ensure smoke extraction or water pressure is maintained during emergency events.
Aanvullende specificaties
- Zwart
- Grijs
Scalar (V/f)
Vector
Op netstroom
Koopgids
- Bevestig het exacte model, onderdeelnummer en specificaties voordat u bestelt.
- Zorg voor compatibiliteit met uw huidige machines of besturingssystemen.
- Neem contact op via sale@etowonauto.com of +8617859788089 voor technische ondersteuning.
- Bekijk de leveringsopties, doorlooptijden en verzendvereisten.
- Volg de instructies van de fabrikant en de beste praktijken tijdens de installatie.
Verzending en Retourneren
Voorraadartikelen worden doorgaans dezelfde werkdag verzonden. Voor producten die momenteel niet op voorraad zijn, kunnen de verzendtijden variëren afhankelijk van de beschikbaarheid. Internationale verzending is mogelijk, en de verzendkosten worden berekend op basis van bestemming, gewicht en gekozen vervoerder.
Retourzendingen worden geaccepteerd binnen 30 dagen na ontvangst, mits de artikelen ongebruikt en in originele staat zijn. De kosten voor retourzending zijn voor rekening van de klant. Neem alstublieft contact met ons op voordat u een artikel retourneert om een retourautorisatie te ontvangen.
Voor meer details kunt u onze Verzend- en Retourbeleid raadplegen.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Snelle verzending
Originele onderdelen voor industriële automatisering beschikbaar voor snelle verzending wereldwijd.
-
Eenvoudige Retourzendingen
30 dagen retourrecht met 12 maanden garantie voor betrouwbare nazorgbescherming.
-
24/7 ondersteuning
Responsieve professionele ondersteuning om stabiele en efficiënte bedrijfsvoering te behouden.
-
Echt & Origineel
100% authentiek, rechtstreeks afkomstig van vertrouwde fabrikanten van industriële automatisering.
Technische & Koopgids
-
Waarom is een failover van 50 ms cruciaal voor slimme fabrieken in Industrie 4.0?
Dit artikel onderzoekt het ABB DCS full-link redundantieontwerp voor farmaceutische productie onder GMP- en Industry ...
-
Wat zijn de hoofdoorzaken van intermitterende TSI-communicatiefouten?
Dit artikel biedt een kwantitatieve probleemoplossingsmethode voor communicatieproblemen tussen GE Fanuc PLC en Bentl...
-
How to Secure Emerson DeltaV DCS Under Industry 4.0?
This article presents practical Emerson DeltaV DCS hardening strategies aligned with IEC 62443 standards for process ...
-
Is Your Metallurgical Plant Losing Millions to Hidden Energy Waste?
Metallurgical plants waste substantial energy due to fragmented PLC and DCS architectures that cannot share real-time...
-
How to Migrate GE Fanuc to Allen-Bradley Without Production Downtime?
This article provides a data-driven migration guide from GE Fanuc to Allen-Bradley PLCs for discrete manufacturing. I...
-
How Can Bently Nevada Kits Cut Centrifugal Machinery Downtime?
This article shows how Bently Nevada turnkey kits reduce unplanned downtime for centrifugal compressors and fans. It ...