Transformeer je huis met de nieuwste multi-elektronica oplossingen, van intelligente verlichting tot spraakgestuurde apparaten, allemaal ontworpen om het leven gemakkelijker, veiliger en meer verbonden te maken.
SKU:VFD2A7MS43PNSAA
Delta VFD2A7MS43PNSAA MS300 VFD | 0.75kW 3-Phase 380-480V
Manufacturer: Delta
Product No.: VFD2A7MS43PNSAA
Product Type: AC Drive
Product Origin: CN
Payment:T/T, Western Union
Weight: 1100g
Shipping port: Xiamen
Warranty: 12 months
Delen
- Snelle levering
- 24/7 Ondersteuning
- Kwaliteitsborging
Beschrijving
Delta VFD2A7MS43PNSAA MS300 Series AC Micro Drive
Product Overview
The VFD2A7MS43PNSAA is a high-performance, compact vector control drive from Delta’s premier MS300 series. Designed for both IM and PM motor control, this 0.75 kW (1 HP) variable frequency drive is engineered to optimize space and efficiency in industrial automation. Featuring an IP20 protection plate and supporting a wide input voltage range of 380V to 480V AC, it is the ideal solution for machine tools, textile machinery, and woodworking applications. Its derivative model, the VFD2A7MS43PNSART, shares the same core high-speed processing capabilities and robust reliability standards.
Core Technical Advantages
This MS300 series drive delivers a rated output current of 2.7A and an apparent output power of 2.1 kVA. It excels in energy management with a remarkably low standby loss of only 5W. The drive’s thermal design is optimized for precision, maintaining full functionality at a maximum operating temperature of 50 °C. With a 400V class power rating, it supports 50/60 Hz supply frequencies and features advanced power loss management; even at 90% frequency and 100% current, the relative power loss remains as low as 2.64%, ensuring maximum energy savings for the end-user.
Technical Specifications
| Feature | Specification |
|---|---|
| Brand | Delta |
| Model Name | VFD2A7MS43PNSAA |
| Rated Power Output | 0.75 kW (1 HP) |
| Rated Supply Voltage | 380 to 480 V (3-Phase) |
| Rated Output Current | 2.7 A |
| Apparent Output Power | 2.1 kVA |
| Protection Rating | IP20 / Open Type |
Efficiency & Loss Data
The MS300 series is built for superior efficiency. Below is the power loss performance for the 0.75kW model:
- 90% Freq / 100% Current: 55.5 W (2.64% Relative Loss)
- 50% Freq / 100% Current: 53.6 W (2.55% Relative Loss)
- 0% Freq / 50% Current: 45.2 W (2.15% Relative Loss)
- Standby Power Consumption: 5 W
Installation & Engineering Guide
When installing the VFD, ensure the mounting surface is capable of supporting the drive's approximate weight of 1.1 kg. To maintain the IP20 rating and ensure proper cooling, follow the prescribed clearance distances within the control cabinet. The drive supports a wide variety of communication protocols and features a built-in USB port for fast parameter copying and firmware updates. Ensure that field wiring follows local electrical codes for 480V systems, and utilize shielded motor cables to minimize electromagnetic interference (EMI) in sensitive environments.
Engineering Advantages
The Delta MS300 series provides one of the most compact footprints in the industry without compromising on torque performance. By utilizing the VFD2A7MS43PNSAA, engineers can achieve significant cabinet space reduction. The drive includes a safe torque off (STO) function as standard, enhancing system safety levels to SIL2/PLd. Its versatility in handling different motor types and its robust performance at a maximum operating temperature of 50 °C make it a future-proof choice for global machine manufacturers seeking reliable and cost-effective motor control solutions.
Technical FAQs
Q1: What is the difference between the "AA" and "RT" derivative models?
A1: The derivative models typically share identical electrical ratings, but may differ in factory default settings or regional hardware versions. Always verify the specific instruction manual for the 'RT' suffix variations.
Q2: Can I run this drive at 60 Hz?
A2: Yes, the drive is designed for both 50 Hz and 60 Hz supply frequencies, and can output frequencies far beyond these for high-speed applications.
Q3: Is an external cooling fan required?
A3: The drive is designed to operate up to 50 °C. For high-density cabinet installations, ensure adequate airflow is maintained; the internal fan is sufficient for most standard operating conditions.
Aanvullende specificaties
- Zwart
- Grijs
Scalar (V/f)
Vector
Op netstroom
Koopgids
- Bevestig het exacte model, onderdeelnummer en specificaties voordat u bestelt.
- Zorg voor compatibiliteit met uw huidige machines of besturingssystemen.
- Neem contact op via sale@etowonauto.com of +8617859788089 voor technische ondersteuning.
- Bekijk de leveringsopties, doorlooptijden en verzendvereisten.
- Volg de instructies van de fabrikant en de beste praktijken tijdens de installatie.
Verzending en Retourneren
Voorraadartikelen worden doorgaans dezelfde werkdag verzonden. Voor producten die momenteel niet op voorraad zijn, kunnen de verzendtijden variëren afhankelijk van de beschikbaarheid. Internationale verzending is mogelijk, en de verzendkosten worden berekend op basis van bestemming, gewicht en gekozen vervoerder.
Retourzendingen worden geaccepteerd binnen 30 dagen na ontvangst, mits de artikelen ongebruikt en in originele staat zijn. De kosten voor retourzending zijn voor rekening van de klant. Neem alstublieft contact met ons op voordat u een artikel retourneert om een retourautorisatie te ontvangen.
Voor meer details kunt u onze Verzend- en Retourbeleid raadplegen.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Snelle verzending
Originele onderdelen voor industriële automatisering beschikbaar voor snelle verzending wereldwijd.
-
Eenvoudige Retourzendingen
30 dagen retourrecht met 12 maanden garantie voor betrouwbare nazorgbescherming.
-
24/7 ondersteuning
Responsieve professionele ondersteuning om stabiele en efficiënte bedrijfsvoering te behouden.
-
Echt & Origineel
100% authentiek, rechtstreeks afkomstig van vertrouwde fabrikanten van industriële automatisering.
Technische & Koopgids
-
Waarom is een failover van 50 ms cruciaal voor slimme fabrieken in Industrie 4.0?
Dit artikel onderzoekt het ABB DCS full-link redundantieontwerp voor farmaceutische productie onder GMP- en Industry ...
-
Wat zijn de hoofdoorzaken van intermitterende TSI-communicatiefouten?
Dit artikel biedt een kwantitatieve probleemoplossingsmethode voor communicatieproblemen tussen GE Fanuc PLC en Bentl...
-
How to Secure Emerson DeltaV DCS Under Industry 4.0?
This article presents practical Emerson DeltaV DCS hardening strategies aligned with IEC 62443 standards for process ...
-
Is Your Metallurgical Plant Losing Millions to Hidden Energy Waste?
Metallurgical plants waste substantial energy due to fragmented PLC and DCS architectures that cannot share real-time...
-
How to Migrate GE Fanuc to Allen-Bradley Without Production Downtime?
This article provides a data-driven migration guide from GE Fanuc to Allen-Bradley PLCs for discrete manufacturing. I...
-
How Can Bently Nevada Kits Cut Centrifugal Machinery Downtime?
This article shows how Bently Nevada turnkey kits reduce unplanned downtime for centrifugal compressors and fans. It ...
