Transformeer je huis met de nieuwste multi-elektronica oplossingen, van intelligente verlichting tot spraakgestuurde apparaten, allemaal ontworpen om het leven gemakkelijker, veiliger en meer verbonden te maken.
SKU:VFD220VP43AFTDA-VFTDA
Delta VFD220VP43AFTDA-VFTDA | High Performance VFD
Manufacturer: Delta
Product No.: VFD220VP43AFTDA-VFTDA
Product Type: AC Drive
Product Origin: CN
Payment:T/T, Western Union
Weight: 8000g
Shipping port: Xiamen
Warranty: 12 months
Delen
- Snelle levering
- 24/7 Ondersteuning
- Kwaliteitsborging
Beschrijving
Product Overview
The Delta VFD220VP43AFTDA-VFTDA is a premier Variable Frequency Drive (VFD) from the high-performance VP series, specifically optimized for fluid machinery such as fans, pumps, and blowers. This 22kW (30HP) drive integrates advanced sensorless vector control (SVC) to deliver precise torque management and energy efficiency. Engineered for industrial 460V three-phase systems, it features a robust hardware architecture that ensures stable operation under fluctuating loads.
Technical Configuration
Model Identification & Logic
- Power Rating (220): Indicates a rated output capacity of 22kW (30 Horsepower), suitable for medium-to-large motor control.
- Series (VP): Specialized series for Fan and Pump applications, featuring enhanced PID control and energy-saving modes.
- Voltage Class (43): Designed for 460V 3-Phase input power systems (operates within 380V–480V range).
- Integrated Filter (AF): Built-in RFI/EMC filter to minimize electromagnetic interference in sensitive industrial environments.
- Hardware Design (TDA): Represents the specific frame size and terminal layout configuration for optimized heat dissipation.
Technical Specifications
| Parameter | Technical Data Details |
|---|---|
| Rated Output Capacity | 34 kVA |
| Rated Output Current | 45 A (Continuous) |
| Maximum Output Voltage | 3-Phase proportional to input (Max 480V) |
| Output Frequency Range | 0.1 to 600.00 Hz |
| Overload Capacity | 120% of rated current for 60 seconds |
| Carrier Frequency | 2 kHz to 15 kHz (Auto-adjusting based on load) |
| Control Method | SVPWM, Sensorless Vector Control (SVC) |
| Protection Level | IP20 / UL Type 1 |
Installation & Engineering Guide
Operational Best Practices
Heat Dissipation: Maintain a minimum clearance of 50mm on the sides and 120mm above/below the drive. The VFD220VP43AFTDA utilizes forced air cooling; ensure the cabinet ambient temperature stays below 50°C to prevent thermal derating.
Wiring Integrity: Use shielded cables for the motor leads to reduce EMI. The maximum recommended cable length without an output reactor is 30 meters. Ensure the ground terminal (E) is connected to a dedicated industrial ground point.
PID Tuning: Utilize the built-in PID feedback loops for constant pressure pump control. Set the sleep/wake-up frequency parameters to maximize energy savings during low-demand periods.
Engineering Advantages
The VFD220VP43AFTDA-VFTDA distinguishes itself through its intelligent energy-saving algorithms, which automatically reduce motor voltage during low-load conditions to decrease power consumption. It features a high-speed communication interface (MODBUS) as standard, allowing seamless integration into PLC-based factory automation networks. The drive's circuit boards are conformal coated to provide resistance against dust and corrosive gases, significantly extending the service life in harsh industrial atmospheres.
Technical FAQs
Q1: Does this model include a built-in braking resistor?
A1: No, for 22kW models, an external braking unit (BUE series) and resistors are required if the application involves high-inertia loads or rapid deceleration cycles.
Q2: Can I use this drive for a constant torque application like a conveyor?
A2: While optimized for fans and pumps (variable torque), it can handle constant torque loads if the current demand does not exceed 45A. However, a VFD-C2000 series might be more appropriate for heavy-start torque needs.
Q3: What is the significance of the "AF" in the model code?
A3: It indicates a built-in EMC filter that complies with EN61800-3 standards, reducing high-frequency noise that could otherwise interfere with nearby sensors or controllers.
Aanvullende specificaties
- Zwart
- Grijs
Scalar (V/f)
Vector
Op netstroom
Koopgids
- Bevestig het exacte model, onderdeelnummer en specificaties voordat u bestelt.
- Zorg voor compatibiliteit met uw huidige machines of besturingssystemen.
- Neem contact op via sale@etowonauto.com of +8617859788089 voor technische ondersteuning.
- Bekijk de leveringsopties, doorlooptijden en verzendvereisten.
- Volg de instructies van de fabrikant en de beste praktijken tijdens de installatie.
Verzending en Retourneren
Voorraadartikelen worden doorgaans dezelfde werkdag verzonden. Voor producten die momenteel niet op voorraad zijn, kunnen de verzendtijden variëren afhankelijk van de beschikbaarheid. Internationale verzending is mogelijk, en de verzendkosten worden berekend op basis van bestemming, gewicht en gekozen vervoerder.
Retourzendingen worden geaccepteerd binnen 30 dagen na ontvangst, mits de artikelen ongebruikt en in originele staat zijn. De kosten voor retourzending zijn voor rekening van de klant. Neem alstublieft contact met ons op voordat u een artikel retourneert om een retourautorisatie te ontvangen.
Voor meer details kunt u onze Verzend- en Retourbeleid raadplegen.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Snelle verzending
Originele onderdelen voor industriële automatisering beschikbaar voor snelle verzending wereldwijd.
-
Eenvoudige Retourzendingen
30 dagen retourrecht met 12 maanden garantie voor betrouwbare nazorgbescherming.
-
24/7 ondersteuning
Responsieve professionele ondersteuning om stabiele en efficiënte bedrijfsvoering te behouden.
-
Echt & Origineel
100% authentiek, rechtstreeks afkomstig van vertrouwde fabrikanten van industriële automatisering.
Technische & Koopgids
-
Can Converged PLC-DCS Architecture Cut Downtime by 22%?
This article examines how PLC-DCS convergence resolves the fragmentation bottleneck in legacy process plants. Drawing...
-
Retrofitting Mixed PLC & DCS Systems?
This article presents a hybrid protocol fusion architecture combining Modbus TCP and EtherNet/IP to overcome communic...
-
Original vs Compatible GE Fanuc PLC Parts?
This guide presents a data-driven methodology for identifying and verifying brand-new, original GE Fanuc 90-30, 90-70...
-
Can Data-Driven Alarm Grading Reduce Turbine Downtime?
This technical article presents a data-driven four-tier alarm grading strategy for Bently Nevada 3500 systems in comb...
-
How does ABB S800 I/O hot swap cut unplanned downtime by 90%?
This article presents quantified operational best practices for ABB S800 I/O hot swap in 24/7 process industries. ...
-
Is Your Refinery DCS Ready for Zero-Trust OT Access Control?
This technical article examines data-driven cybersecurity hardening strategies for Emerson DeltaV DCS in refiner...