Transformeer je huis met de nieuwste multi-elektronica oplossingen, van intelligente verlichting tot spraakgestuurde apparaten, allemaal ontworpen om het leven gemakkelijker, veiliger en meer verbonden te maken.
SKU:330905-00-25-10-01-05
Bently Nevada 3300 NSv Probe 330905-00-25-10-01-05
Manufacturer: Bently Nevada
Product No.: 330905-00-25-10-01-05
Product Type: Proximity Probe
Product Origin: USA
Payment:T/T, Western Union
Weight: 500g
Shipping port: Xiamen
Warranty: 12 months
Delen
- Snelle levering
- 24/7 Ondersteuning
- Kwaliteitsborging
Beschrijving
Product Overview
The Bently Nevada 330905-00-25-10-01-05 is a 3300 NSv proximity probe with an M10×1 thread, 250 mm case length, and 1.0 m miniature coaxial ClickLoc cable. It measures shaft vibration and axial position on turbines, compressors, and pumps with a 1.5 mm linear range and 7.87 V/mm scale factor. Each probe weighs approximately 0.5 kg, keeping bracket loading low. The PPS probe tip and AISI 304 stainless steel case resist chemical attack in process compressor service.
Technical Configuration
Model Code Breakdown
The 330905 code defines the NSv probe family. The -00- option sets a 0 mm unthreaded length. The -25- option sets a 250 mm overall case length. The 10 option sets a 1.0 m total length. The 01 option specifies a miniature coaxial ClickLoc connector with connector protector and standard cable. The -05 agency approval option covers multiple approvals.
Core Hardware
The probe uses a polyphenylene sulfide tip and AISI 304 stainless steel case. The 75 Ω coaxial FEP cable carries the signal to the protected ClickLoc connector. A Viton O-ring seals differential pressure between the probe tip and case. The probe is mechanically and electrically interchangeable with the earlier 3300 RAM probe and extension cable.
Technical Specifications
| Parameter | Specification |
| Linear Range | 1.5 mm (60 mils), 0.25 to 1.75 mm |
| Recommended Gap | 1.0 mm (40 mils) |
| Scale Factor | 7.87 V/mm (200 mV/mil) +12.5%/-20% |
| Deviation from Best Fit | Less than ±0.06 mm (±2.3 mils) |
| Frequency Response | 0 to 10 kHz, +0/-3 dB typical |
| Probe DC Resistance | 4.2 ± 0.5 ohms at 1.0 m |
| Operating Temperature | -52°C to +177°C (-62°F to +351°F) |
| Minimum Bend Radius | 25.4 mm (1.0 in) |
| Target Size | Min 8.9 mm, recommended 13 mm |
| Thread | M10×1, 15 mm max engagement |
| Probe Case Torque | 7.5 N·m recommended, 22.6 N·m max |
| Field Wiring | 0.2 to 1.5 mm², max 305 m |
| Weight | Approx. 0.5 kg |
Installation Guide
Set the gap at 1.0 mm (40 mils) using a feeler gauge or the -1 to -13 Vdc output reading. Keep the minimum bend radius at 25.4 mm to avoid cable damage. Apply 7.5 N·m torque to the M10×1 probe case, never exceeding 22.6 N·m. Use three-conductor shielded triad cable for field wiring and keep total length under 305 meters. At roughly 0.5 kg, the probe adds minimal load to the mounting bracket. Confirm the Viton O-ring seats correctly before pressurizing the machine.
Engineering Advantages
The NSv probe delivers higher chemical resistance than the 3300 RAM probe, extending service life in process compressor environments. Its side-view characteristics outperform the 3000-series 190 probe when gapping at the same distance from the target. The probe and extension cable interchange directly with existing 3300 RAM installations, cutting upgrade downtime. The lightweight 0.5 kg body reduces bracket stress, while the PPS tip and stainless steel case hold up under -52°C to +177°C operating ranges.
Technical FAQs
Q1: How do I set the probe gap?
A1: Target 1.0 mm (40 mils), which corresponds to roughly -10 Vdc. Confirm the reading falls within the -1 to -13 Vdc linear range before locking the probe.
Q2: What does the -05 approval option add?
A2: The -05 option carries multiple agency approvals, qualifying the probe for hazardous-area installations across several certification schemes. Check the nameplate against your site zone requirements.
Q3: What does the 01 connector option include?
A3: The 01 option adds a miniature coaxial ClickLoc connector with a connector protector and standard cable. The 10 option sets the total length to 1.0 meter (39 in).
Aanvullende specificaties
Scalar (V/f)
Vector
Op netstroom
Koopgids
- Bevestig het exacte model, onderdeelnummer en specificaties voordat u bestelt.
- Zorg voor compatibiliteit met uw huidige machines of besturingssystemen.
- Neem contact op via sale@etowonauto.com of +8617859788089 voor technische ondersteuning.
- Bekijk de leveringsopties, doorlooptijden en verzendvereisten.
- Volg de instructies van de fabrikant en de beste praktijken tijdens de installatie.
Verzending en Retourneren
Voorraadartikelen worden doorgaans dezelfde werkdag verzonden. Voor producten die momenteel niet op voorraad zijn, kunnen de verzendtijden variëren afhankelijk van de beschikbaarheid. Internationale verzending is mogelijk, en de verzendkosten worden berekend op basis van bestemming, gewicht en gekozen vervoerder.
Retourzendingen worden geaccepteerd binnen 30 dagen na ontvangst, mits de artikelen ongebruikt en in originele staat zijn. De kosten voor retourzending zijn voor rekening van de klant. Neem alstublieft contact met ons op voordat u een artikel retourneert om een retourautorisatie te ontvangen.
Voor meer details kunt u onze Verzend- en Retourbeleid raadplegen.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Snelle verzending
Originele onderdelen voor industriële automatisering beschikbaar voor snelle verzending wereldwijd.
-
Eenvoudige Retourzendingen
30 dagen retourrecht met 12 maanden garantie voor betrouwbare nazorgbescherming.
-
24/7 ondersteuning
Responsieve professionele ondersteuning om stabiele en efficiënte bedrijfsvoering te behouden.
-
Echt & Origineel
100% authentiek, rechtstreeks afkomstig van vertrouwde fabrikanten van industriële automatisering.
Technische & Koopgids
-
How Does 1756 Analog I/O Calibration Drift Affect PLC Accuracy?
This article examines calibration drift in Allen-Bradley ControlLogix 1756 analog I/O modules, presenting quanti...
-
Why Do 31% of ABB 800xA S800 IO Hot Swaps Fail in DCS Systems?
ABB 800xA S800 hot swap failures rarely stem from defective hardware. Field data from 142 card replacement jobs shows...
-
How Do You Diagnose Degraded MTL Surge Protection Devices?
This article presents field-proven diagnostic checks, aging benchmarks, and installation rules for MTL surge pro...
-
How Can You Stop Nuisance Trips on Bently Nevada TSI Systems?
Nuisance trips on Bently Nevada TSI racks cost power and oil & gas plants $18,000 to $45,000 per event and occur ...
-
When Should You Replace a Yokogawa Analog IO Card?
This article breaks down Yokogawa analog AI/AO card calibration tolerances, drift aging benchmarks, and formal replac...
-
What Performance Gains Does S7-1500 Offer Over Legacy S7 PLCs?
Legacy Siemens S7-300 and S7-400 PLCs face spare-part shortages, rising failure rates and limited network capability,...