Transformeer je huis met de nieuwste multi-elektronica oplossingen, van intelligente verlichting tot spraakgestuurde apparaten, allemaal ontworpen om het leven gemakkelijker, veiliger en meer verbonden te maken.
SKU:1769-ASCII
Allen-Bradley 1769-ASCII | Dual Port ASCII Communication
Manufacturer: Allen-Bradley
Product No.: 1769-ASCII
Product Type: Communication Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 200g
Shipping port: Xiamen
Warranty: 12 months
Delen
- Snelle levering
- 24/7 Ondersteuning
- Kwaliteitsborging
Beschrijving
Product Overview
The Allen-Bradley 1769-ASCII is a high-performance, dual-port serial communication module designed for the CompactLogix and MicroLogix 1500 platforms. This module enables seamless integration between your PLC and various ASCII-based devices, such as barcode scanners, weigh scales, serial printers, and legacy sensors.
Technical Configuration & Hardware Architecture
The 1769-ASCII features a sophisticated hardware design that prioritizes signal purity and multi-protocol flexibility. It functions as an intelligent I/O module that resides directly on the 1769 backplane.
Dual Isolated Port Topology
Each port on the 1769-ASCII is electronically isolated to 30V continuous, protecting the backplane from ground loops and induced noise common in long-run serial cabling. Port 1 is optimized for RS-232 and RS-422 full-duplex communication, while Port 2 provides robust RS-485 multi-drop capabilities, allowing for versatile field device networking.
Backplane Integration
The module draws its 425mA operating current directly from the 5V DC backplane, simplifying enclosure wiring by eliminating the need for external power supplies. This hardware-level integration ensures that the communication ports are synchronized with the controller's internal clock for precise data time-stamping.
Technical Specifications
| Feature | Specification |
|---|---|
| Model Number | 1769-ASCII |
| Number of Ports | 2 Isolated Ports (DB-9 Male) |
| Protocols Supported | RS-232, RS-422, RS-485 |
| Max Baud Rate | 115.2 kbps per port |
| Backplane Current Draw | 425mA @ 5V DC |
| Operating Temperature | 0°C to 60°C (32°F to 140°F) |
| Isolation Voltage | 30V continuous (710V DC for 1s) |
Installation & Engineering Guide
To ensure optimal performance of the 1769-ASCII, engineers must adhere to specific mechanical and electrical placement rules.
Power Supply Distance Rating
The 1769-ASCII has a power supply distance rating of 4. This means the module must be installed within four slots of the 1769 system power supply to ensure it receives consistent, regulated voltage for its dual-port circuitry.
Cabling and Grounding
For high-reliability data transmission, use high-quality shielded twisted-pair cabling (such as Belden 8761). Proper termination of the cable shield at the chassis ground is essential to minimize the impact of EMI on the ASCII string data, especially when operating at the maximum baud rate of 115.2 kbps.
Engineering Advantages
- Simultaneous Communication: Both ports operate independently, allowing the system to read from a barcode scanner on Port 1 while sending data to a printer on Port 2.
- Protocol Versatility: Native support for multiple RS-standards allows for easy retrofitting of legacy factory equipment into modern ControlLogix-based architectures.
- Rugged Industrial Design: Capable of operating in high-temperature environments (up to 60°C) without the need for active cooling, provided that the 50mm clearance rule is followed.
Technical FAQs
Q1: Does the 1769-ASCII support Modbus RTU?
A1: While the module is hardware-capable of RS-485, it is primarily designed for raw ASCII string communication. Implementing Modbus RTU requires manual ladder logic programming to handle the Modbus frame and CRC checks.
Q2: Can I mix RS-232 and RS-485 on the same module?
A2: Yes. The 1769-ASCII ports are independent. You can configure Port 1 for RS-232 communication with a PC and Port 2 for an RS-485 network of sensors simultaneously.
Q3: Is external power required for the serial signal?
A3: No. The module generates the necessary signal voltages internally from the 5V backplane power. However, the connected device must provide its own power source for its communication interface.
Aanvullende specificaties
Scalar (V/f)
Vector
Op netstroom
Koopgids
- Bevestig het exacte model, onderdeelnummer en specificaties voordat u bestelt.
- Zorg voor compatibiliteit met uw huidige machines of besturingssystemen.
- Neem contact op via sale@etowonauto.com of +8617859788089 voor technische ondersteuning.
- Bekijk de leveringsopties, doorlooptijden en verzendvereisten.
- Volg de instructies van de fabrikant en de beste praktijken tijdens de installatie.
Verzending en Retourneren
Voorraadartikelen worden doorgaans dezelfde werkdag verzonden. Voor producten die momenteel niet op voorraad zijn, kunnen de verzendtijden variëren afhankelijk van de beschikbaarheid. Internationale verzending is mogelijk, en de verzendkosten worden berekend op basis van bestemming, gewicht en gekozen vervoerder.
Retourzendingen worden geaccepteerd binnen 30 dagen na ontvangst, mits de artikelen ongebruikt en in originele staat zijn. De kosten voor retourzending zijn voor rekening van de klant. Neem alstublieft contact met ons op voordat u een artikel retourneert om een retourautorisatie te ontvangen.
Voor meer details kunt u onze Verzend- en Retourbeleid raadplegen.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Snelle verzending
Originele onderdelen voor industriële automatisering beschikbaar voor snelle verzending wereldwijd.
-
Eenvoudige Retourzendingen
30 dagen retourrecht met 12 maanden garantie voor betrouwbare nazorgbescherming.
-
24/7 ondersteuning
Responsieve professionele ondersteuning om stabiele en efficiënte bedrijfsvoering te behouden.
-
Echt & Origineel
100% authentiek, rechtstreeks afkomstig van vertrouwde fabrikanten van industriële automatisering.
Technische & Koopgids
-
Waarom is een failover van 50 ms cruciaal voor slimme fabrieken in Industrie 4.0?
Dit artikel onderzoekt het ABB DCS full-link redundantieontwerp voor farmaceutische productie onder GMP- en Industry ...
-
Wat zijn de hoofdoorzaken van intermitterende TSI-communicatiefouten?
Dit artikel biedt een kwantitatieve probleemoplossingsmethode voor communicatieproblemen tussen GE Fanuc PLC en Bentl...
-
How to Secure Emerson DeltaV DCS Under Industry 4.0?
This article presents practical Emerson DeltaV DCS hardening strategies aligned with IEC 62443 standards for process ...
-
Is Your Metallurgical Plant Losing Millions to Hidden Energy Waste?
Metallurgical plants waste substantial energy due to fragmented PLC and DCS architectures that cannot share real-time...
-
How to Migrate GE Fanuc to Allen-Bradley Without Production Downtime?
This article provides a data-driven migration guide from GE Fanuc to Allen-Bradley PLCs for discrete manufacturing. I...
-
How Can Bently Nevada Kits Cut Centrifugal Machinery Downtime?
This article shows how Bently Nevada turnkey kits reduce unplanned downtime for centrifugal compressors and fans. It ...
