Product Overview
The Allen-Bradley 1756-IM16I is a premium, heavy-duty 16-point isolated AC digital input module belonging to the high-performance ControlLogix automation platform. Engineered for challenging industrial environments with diverse electrical grids, this module provides complete point-to-point isolation across all 16 channels, operating within a nominal voltage category of 240 Volts AC (159 to 265 VAC range). Weighing approximately 0.30 kg (0.66 lbs), this chassis-based processor card monitors high-voltage field statuses, executes precise Change-of-State (COS) tracking, and protects the core PLC backplane from dangerous multi-phase cross-faults or erratic voltage spikes.
Core Technical Advantages
- Per-Point Individual Isolation: Features 16 completely independent isolated channel grids, permitting the simultaneous monitoring of distinct AC phases or separate field power sources on a single module without phase short-circuit risks.
- Programmable Logic Filter Times: Supports highly customizable input delay filters (selectable up to 18 ms) combined with rapid hardware response times to successfully suppress contact bounce and high-frequency line noise.
- Advanced Thermal Derating Matrix: Optimized to safely dissipate up to 5.8 Watts at 60 degrees Celsius, providing robust multi-channel configuration charts to handle continuous high-temperature field operations with maximum stability.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Brand / Manufacturer | Allen-Bradley / Rockwell Automation (ControlLogix System) |
| Model Part Number | 1756-IM16I (UPC 10612598171344) |
| Gross Weight | 0.30 kg (0.66 lbs) |
| Module Category | Isolated Digital AC Input Module |
| Discrete Input Count | 16 Individually Isolated Inputs (Point-to-Point Isolation) |
| Nominal Voltage Category | 240 Volts AC (50 / 60 Hz operating frequency) |
| Continuous Operating Range | 159 to 265 Volts AC (47 to 63 Hz frequency bandwidth) |
| On-State Current Threshold | 5 mA minimum at 159 VAC / 13 mA maximum at 265 VAC |
| Off-State Threshold Limits | Maximum 40 Volts AC / Maximum 2.5 mA leakage current |
| Maximum Inrush Current | 250 mA peak inrush loading capability |
| Backplane Current Requirements | 100 mA at 5 VDC / 3 mA at 24 VDC (Total Bus Power: 0.58 Watts) |
| Thermal / Power Dissipation | 5.8 Watts maximum power loss / 19.78 BTU/hour thermal dissipation |
| Compatible Terminal Housing | 36-Pin Removable Terminal Blocks (1756-TBCH or 1756-TBS6H) |
Installation & Engineering Guide
- Chassis Placement & Insertion: Ensure the primary system power supply is completely isolated before beginning installation. Align the 0.30 kg hardware frame within the selected slot guides of the 1756 ControlLogix chassis, pushing it backward firmly until the top and bottom retention clips snap completely over the structural chassis rail tabs.
- 36-Pin RTB Wiring Configurations: Terminate your 240V AC field inputs through an approved 1756-TBCH (extended clamp) or 1756-TBS6H (spring clamp) 36-pin removable terminal block. Because each channel is fully isolated, always run both the active signal line and its respective neutral return line directly to the designated channel terminal pair.
- Operating Environment Derating: Monitor your local enclosure temperature guidelines closely. When executing full system density, all 16 channels can remain ON up to 30 degrees Celsius at 265 VAC; however, if operating at 40 degrees Celsius, limit simultaneous active channels to 8 points max, or derate the operational input limit down to 242 VAC at 60 degrees Celsius with all channels active.
Technical FAQs
Q1: How is the total execution delay calculated for the 1756-IM16I AC input paths?
A1: The total turnaround delay from screw to backplane is a combination of native hardware circuit latency and user-selected filter times. Going from Off-to-On, it equals the 10 ms max hardware delay plus a selectable 1 or 2 ms filter. Going from On-to-Off, it is an 8 ms max hardware delay plus a selectable 9 or 18 ms filter block.
Q2: What is the main advantage of point-to-point isolation on this specific digital input card?
A2: Unlike standard grouped inputs that share a common return bus, per-point isolation provides a completely separate circuit for each of the 16 paths. This allows you to mix different AC voltage phases or feed signals from entirely separate safety substations into a single physical card without risk of catastrophic cross-phase failure.
Q3: Does the lightweight 0.30 kg construction of this module compromise its long-term reliability?
A3: No. At roughly 0.30 kg, its specialized compact frame is optimized to save chassis balance while providing rugged structural components that comply with high-voltage industrial insulation profiles, fully meeting standard ControlLogix ratings for mechanical shock and vibrations.
Aanvullende specificaties
Scalar (V/f)
Vector
Op netstroom
Koopgids
- Bevestig het exacte model, onderdeelnummer en specificaties voordat u bestelt.
- Zorg voor compatibiliteit met uw huidige machines of besturingssystemen.
- Neem contact op via sale@etowonauto.com of +8617859788089 voor technische ondersteuning.
- Bekijk de leveringsopties, doorlooptijden en verzendvereisten.
- Volg de instructies van de fabrikant en de beste praktijken tijdens de installatie.
Verzending en Retourneren
Voorraadartikelen worden doorgaans dezelfde werkdag verzonden. Voor producten die momenteel niet op voorraad zijn, kunnen de verzendtijden variëren afhankelijk van de beschikbaarheid. Internationale verzending is mogelijk, en de verzendkosten worden berekend op basis van bestemming, gewicht en gekozen vervoerder.
Retourzendingen worden geaccepteerd binnen 30 dagen na ontvangst, mits de artikelen ongebruikt en in originele staat zijn. De kosten voor retourzending zijn voor rekening van de klant. Neem alstublieft contact met ons op voordat u een artikel retourneert om een retourautorisatie te ontvangen.
Voor meer details kunt u onze Verzend- en Retourbeleid raadplegen.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Snelle verzending
Originele onderdelen voor industriële automatisering beschikbaar voor snelle verzending wereldwijd.
-
Eenvoudige Retourzendingen
30 dagen retourrecht met 12 maanden garantie voor betrouwbare nazorgbescherming.
-
24/7 ondersteuning
Responsieve professionele ondersteuning om stabiele en efficiënte bedrijfsvoering te behouden.
-
Echt & Origineel
100% authentiek, rechtstreeks afkomstig van vertrouwde fabrikanten van industriële automatisering.
Technische & Koopgids
-
Dual Compliance Standards for Pharma Automation?
This article presents a quantified engineering methodology for explosion-proof PLC and DCS system design in GMP-certi...
-
How to Avoid Bulk Sourcing Risks for Power Plant Control Spares?
This guide presents field-validated strategies for bulk sourcing industrial control spares in power plants. It q...
-
What Are the Hidden Costs of Fake PLC and DCS Modules?
This guide presents data-driven verification protocols for imported industrial control spare parts, addressing the es...
-
Redundant PLC + DCS: 18.6% Fan Energy Savings?
This case study documents a full automation retrofit for a 300 TPD waste incineration plant. By integrating Emerson D...
-
Can Proper Warehousing Cut Automation Hardware Failures 80%?
This technical guide presents quantified storage and maintenance standards for industrial PLC, DCS, and TSI spare par...
-
Can Industrial Control Upgrades Cut Unplanned Downtime by 90%?
This article examines why legacy PLC, DCS, and vibration monitoring systems demand urgent retrofit in 2026. Citing re...