Product Overview

The Allen-Bradley 1756-2WS (developed in collaboration with Hardy Process Solutions) is a high-precision, dual-channel weigh scale module designed for direct integration into the flagship ControlLogix PLC platform. This specialized single-slot coprocessor card interfaces directly with strain-gauge load cells, eliminating the need for independent external weight transmitters. Weighing 0.5 kg (1.1 lbs), the module provides high-speed, 16-bit internal resolution weight tracking directly to the controller backplane, making it an ideal solution for fast-acting batching, heavy tank level tracking, and automated filling applications.

Core Technical Advantages

  • Integrated Dual-Scale Architecture: Features two completely independent weighing channels capable of driving up to eight 350-ohm load cells (four cells per channel) simultaneously for multi-vessel process management.
  • Advanced C2® Electronic Calibration: Supports electronic sensor matching, enabling automated system calibration via software parameters without handling dangerous, heavy physical test weights on the factory floor.
  • WAVESAVER® Mechanical Filtering: Embedded hardware algorithms successfully suppress plant-floor floor vibrations, industrial shock waves, and plant piping resonance to deliver rock-steady weight data under tough conditions.

Technical Specifications

Parameter Specification Details
Brand / Manufacturer Allen-Bradley (Rockwell Automation) / Hardy Instruments
Model Part Number 1756-2WS (ControlLogix Series)
Gross Weight 0.5 kg (1.1 lbs)
Module Function Dual-Channel Weigh Scale Processor
Load Cell Support Up to 4 load cells per channel (8 load cells total capacity)
Signal Conversion Range minus 0.3 mV to plus 15.3 mV DC bridge inputs
Bridge Excitation Output 5 VDC regulated sensor excitation loop
Update Conversion Speed 50 independent data updates per second
Internal Digital Resolution 1:8,388,608 internal counts mapping index
Backplane Current Draw Less than 1 Amp at 5 VDC controller chassis bus
Operating Temperature 32 deg F to 140 deg F (0 deg C to 60 deg C)

Installation & Engineering Guide

  • Chassis Placement Protocol: Leveraging hot-swappable architecture, the 0.5 kg hardware frame can be firmly slid into any open slot of a standard ControlLogix chassis. Guide the module along the plastic alignment tracks until the rear circuit contacts lock tightly into the active backplane.
  • Field Scale Termination: Wire your load cell bridge cables directly into the dedicated removable terminal housing. To ensure total structural noise cancellation through the Wavesaver filter system, keep low-level millivolt lines away from variable frequency drives (VFDs) and high-current conduits.
  • Software Data Configuration: Add the 1756-2WS module directly inside Studio 5000 via its custom Add-On Profile (AOP). From the tag configuration screens, engineers can select selectable digital averaging rates (from 1 to 255 samples) and assign Net, Gross, or Rate-of-Change measurement tracks to local control routines.

Technical FAQs

Q1: Why is the Allen-Bradley 1756-2WS module co-branded with Hardy Instruments?
A1: The module was engineered using Hardy's patented process weighing technology—including WAVESAVER and C2 electronic calibration—and packaged into a native ControlLogix card format to let users track raw scale processes directly inside the PLC environment.

Q2: How does the module handle real-time material flow calculations?
A2: The onboard processor automatically evaluates the weight data change vector over time to generate a direct Rate-of-Change value. This allows the PLC to track instant loss-in-weight or gain-in-weight flow rates without using heavy CPU calculation blocks.

Q3: Does the 0.5 kg module framework require external power injection to drive eight load cells?
A3: No. The card draws under 1 Amp from the 5 VDC ControlLogix backplane slot to internally generate the regulated 5 VDC bridge excitation voltage needed to power up all eight connected field sensors.

🏷️ Tags: Weigh Scale Module

Scalar (V/f)

Vector

Op netstroom

  • Bevestig het exacte model, onderdeelnummer en specificaties voordat u bestelt.
  • Zorg voor compatibiliteit met uw huidige machines of besturingssystemen.
  • Neem contact op via sale@etowonauto.com of +8617859788089 voor technische ondersteuning.
  • Bekijk de leveringsopties, doorlooptijden en verzendvereisten.
  • Volg de instructies van de fabrikant en de beste praktijken tijdens de installatie.

Voorraadartikelen worden doorgaans dezelfde werkdag verzonden. Voor producten die momenteel niet op voorraad zijn, kunnen de verzendtijden variëren afhankelijk van de beschikbaarheid. Internationale verzending is mogelijk, en de verzendkosten worden berekend op basis van bestemming, gewicht en gekozen vervoerder.

Retourzendingen worden geaccepteerd binnen 30 dagen na ontvangst, mits de artikelen ongebruikt en in originele staat zijn. De kosten voor retourzending zijn voor rekening van de klant. Neem alstublieft contact met ons op voordat u een artikel retourneert om een retourautorisatie te ontvangen.

Voor meer details kunt u onze Verzend- en Retourbeleid raadplegen.

Alle details bekijken

ZORG VOOR BETROUWBARE MACHINEPRESTATIES

Transformeer je huis met de nieuwste multi-elektronica oplossingen, van intelligente verlichting tot spraakgestuurde apparaten, allemaal ontworpen om het leven gemakkelijker, veiliger en meer verbonden te maken.