Product Overview
The Allen-Bradley 1746-OA16 is a 16-point discrete AC output module belonging to the SLC 500 modular I/O hardware system by Rockwell Automation. Designed for control of AC-powered actuators, solenoids, motor starters, and indicator lights, this module operates across a nominal 120/240 V AC supply voltage with a broad continuous operating range of 85 to 265 V AC (47–63 Hz).
Organized into two (2) individually isolated channels of eight (8) outputs each, the 1746-OA16 features optical coupling and integrated filter circuitry for signal noise suppression. Weighing approximately 0.38 kg (0.84 lbs), it installs into any single slot of an SLC 500 local or remote chassis, drawing 0.370 A (370 mA) from the 5.1 V DC backplane supply while providing convenient maintenance via removable terminal blocks (RTBs).
Core Technical Advantages
- Dual Grouped Channel Architecture: Configured with 16 AC output points split into two isolated groups of 8 channels, allowing distinct phase or voltage source control across banks.
- High Inrush Surge Handling: Supports surge currents up to 10.0 A per point for 25 ms, enabling safe switching of inductive loads without damaging output triacs.
- Removable Terminal Block (RTB) Design: Simplifies module replacement and field servicing without requiring the rewiring of individual field connections.
- Optical Noise Isolation & Status LEDs: Features full optical isolation between backplane logic and field side circuits, accompanied by front-panel status LEDs for rapid visual diagnostics.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Brand / Manufacturer | Allen-Bradley / Rockwell Automation |
| Catalog Part Number | 1746-OA16 |
| Product Series | SLC 500 Modular I/O Series |
| Module Type | Digital / Discrete AC Output Module |
| Number of Outputs | 16 AC outputs (2 groups of 8 channels) |
| Nominal Output Voltage | 120 / 240 V AC (47 to 63 Hz) |
| Operating Voltage Range | 85 to 265 V AC |
| Continuous Current per Point | 0.50 A @ 30°C (86°F) | 0.25 A @ 60°C (140°F) |
| Continuous Current per Module | 8.0 A max @ 30°C (86°F) | 4.0 A max @ 60°C (140°F) |
| Minimum Load Current | 10 mA per channel |
| Surge Current per Point | 10.0 A maximum for 25 ms |
| On-State Voltage Drop | 1.50 V AC @ 0.50 A load current |
| Off-State Leakage Current | 2 mA maximum |
| Signal Delay Times | OFF-to-ON: 1 ms | ON-to-OFF: 11.0 ms |
| Backplane Current Consumption | 0.370 A (370 mA) @ 5.1 V DC |
| Slot Width & Wiring Wiring | Single slot / Removable Terminal Block (RTB) |
| Operating Temperature / Humidity | 0°C to 60°C (32°F to 140°F) | 5% to 95% Non-condensing |
| Estimated Shipping Weight | Approx. 0.38 kg (0.84 lbs) |
Installation & Handling Guidelines
- Chassis Power Off: Always remove system power from the SLC 500 chassis before inserting or removing the 1746-OA16 module to prevent backplane damage.
- Terminal Block Removal: Utilize the release tabs on the Removable Terminal Block (RTB) to disconnect field wiring as a single unit when replacing hardware.
- Thermal Derating Verification: Ensure load currents stay under 0.25 A per point if cabinet operating temperatures exceed 30°C (86°F) up to the 60°C (140°F) threshold.
Technical FAQs
Q1: What is the continuous current rating per point for the Allen-Bradley 1746-OA16 module?
A1: It supports 0.50 A per point at 30°C, derating to 0.25 A per point at 60°C.
Q2: How much backplane current does the 1746-OA16 module draw?
A2: The module consumes 370 mA (0.370 A) at 5.1 V DC from the SLC chassis power supply.
Q3: Does the 1746-OA16 output module require wiring removal during replacement?
A3: No, it features a removable terminal block (RTB) that allows module swapping without disconnecting individual wires.
Aanvullende specificaties
Scalar (V/f)
Vector
Op netstroom
Koopgids
- Bevestig het exacte model, onderdeelnummer en specificaties voordat u bestelt.
- Zorg voor compatibiliteit met uw huidige machines of besturingssystemen.
- Neem contact op via sale@etowonauto.com of +8617859788089 voor technische ondersteuning.
- Bekijk de leveringsopties, doorlooptijden en verzendvereisten.
- Volg de instructies van de fabrikant en de beste praktijken tijdens de installatie.
Verzending en Retourneren
Voorraadartikelen worden doorgaans dezelfde werkdag verzonden. Voor producten die momenteel niet op voorraad zijn, kunnen de verzendtijden variëren afhankelijk van de beschikbaarheid. Internationale verzending is mogelijk, en de verzendkosten worden berekend op basis van bestemming, gewicht en gekozen vervoerder.
Retourzendingen worden geaccepteerd binnen 30 dagen na ontvangst, mits de artikelen ongebruikt en in originele staat zijn. De kosten voor retourzending zijn voor rekening van de klant. Neem alstublieft contact met ons op voordat u een artikel retourneert om een retourautorisatie te ontvangen.
Voor meer details kunt u onze Verzend- en Retourbeleid raadplegen.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Snelle verzending
Originele onderdelen voor industriële automatisering beschikbaar voor snelle verzending wereldwijd.
-
Eenvoudige Retourzendingen
30 dagen retourrecht met 12 maanden garantie voor betrouwbare nazorgbescherming.
-
24/7 ondersteuning
Responsieve professionele ondersteuning om stabiele en efficiënte bedrijfsvoering te behouden.
-
Echt & Origineel
100% authentiek, rechtstreeks afkomstig van vertrouwde fabrikanten van industriële automatisering.
Technische & Koopgids
-
How Does TSI Integration Reduce Turbine False Trip Risks?
This article examines data-driven turbine safety monitoring and mechanical fault diagnosis within industrial automati...
-
Can turn-key automation services really cut plant downtime by 47%?
This article examines how fragmented PLC, DCS, TSI, and power-protection systems drive hidden operational losses in p...
-
Is Your Manufacturing Execution Still Stuck in Open-Loop Mode?
This article examines how closed-loop automated control resolves the critical disconnect between production planning ...
-
Can Predictive Analytics Cut Factory Automation Downtime?
This article examines how predictive abnormality pre-judgment technology addresses the economic burden of reactive fa...
-
Is Full PLC Replacement Best for Brown-Field Automation?
This technical article analyzes the hidden costs of full-scale PLC and DCS hardware replacement in brown-field plants...
-
Is Your DCS Logic Tuning Ready for Real-World Production Loads?
This article examines the critical role of physical on-site commissioning and logic tuning in industrial automation, ...