Transformeer je huis met de nieuwste multi-elektronica oplossingen, van intelligente verlichting tot spraakgestuurde apparaten, allemaal ontworpen om het leven gemakkelijker, veiliger en meer verbonden te maken.
SKU:1746-NR8
Allen-Bradley 1746-NR8 RTD Module Input SLC 500
Manufacturer: Allen-Bradley
Product No.: 1746-NR8
Product Type: Analog Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 280g
Shipping port: Xiamen
Warranty: 12 months
Delen
- Snelle levering
- 24/7 Ondersteuning
- Kwaliteitsborging
Beschrijving
Product Overview
The Allen-Bradley 1746-NR8 is a high-performance RTD (Resistance Temperature Detector) and resistance analog input module for the SLC 500 PLC platform. Equipped with eight independent input channels, this module is engineered for precision temperature monitoring in complex industrial processes. By utilizing advanced Sigma-Delta Modulation for A/D conversion, it achieves an exceptional temperature resolution of 0.01°C. Whether monitoring thermal variations in food processing or managing resistance ranges for heavy machinery, the 1746-NR8 provides the high-density I/O capability required to maintain tight process control.
Technical Configuration
The 1746-NR8 is designed for maximum versatility within an SLC 500 chassis:
- Channel Count: 8 high-accuracy input channels for RTD or direct resistance signals.
- Input Ranges: Supports multiple resistance ranges (0–150 Ω, 0–300 Ω, 0–500 Ω, and 0–1000 Ω).
- Conversion Technology: Sigma-Delta Modulation ensures superior noise rejection and measurement linearity.
- Update Rates: Fully adjustable from 6 ms up to 2 seconds to match application dynamics.
- Slot Compatibility: Installs into any available I/O slot of an SLC 500 chassis (except Slot 0).
Technical Specifications
| Parameter | Specification |
|---|---|
| Temperature Resolution | 0.01°C |
| Step Response Time | 60 ms (In) / 2.5 ms (Out) |
| Backplane Current (5V) | 100 mA |
| Backplane Current (24V) | 55 mA |
| Operating Temperature | 0°C to 60°C (32°F to 140°F) |
| Power Consumption | 1.82 W Maximum |
Installation Guide
To integrate the 1746-NR8 into your SLC 500 system, verify that your power supply has sufficient current capacity for the module's 5V and 24V DC backplane requirements.
Wiring and Shielding
RTD signals are highly sensitive to electrical noise. For optimal precision, use high-quality shielded twisted-pair cable for all sensor connections. Ground the cable shield at the module end only to prevent ground loops. The module supports 2, 3, or 4-wire RTD configurations; however, 3 or 4-wire setups are highly recommended to compensate for lead-wire resistance, which is essential for maintaining the rated 0.01°C resolution. Ensure the module is firmly seated and the chassis lever is locked before applying power.
Engineering Advantages
The 1746-NR8 stands out for its "Precision Performance" profile, offering a step response as fast as 60 ms for dynamic thermal tracking. Despite its advanced circuitry, the module maintains a lightweight profile with a net weight of approximately 0.28 kg, minimizing the physical stress on the backplane connectors. Its wide operating temperature range (0–60°C) makes it resilient in non-conditioned industrial environments. Furthermore, the adjustable update time allows engineers to prioritize either high-speed data acquisition for fast-moving processes or heavy filtering for high-stability measurements in noisy environments.
Technical FAQs
Q1: Can I mix different RTD types on the same module?
A1: Yes, the 1746-NR8 allows you to configure each channel individually through the SLC 500 programming software, supporting various RTD types and resistance ranges simultaneously.
Q2: Why does the module use Sigma-Delta Modulation?
A2: This modulation technique provides excellent high-frequency noise rejection and high resolution, which is critical when dealing with the low-voltage signals produced by RTD sensors.
Q3: Is lead-wire compensation automatic?
A3: The module automatically compensates for lead-wire resistance when using 3-wire or 4-wire sensor configurations, ensuring that only the sensor's resistance is measured.
Aanvullende specificaties
Scalar (V/f)
Vector
Op netstroom
Koopgids
- Bevestig het exacte model, onderdeelnummer en specificaties voordat u bestelt.
- Zorg voor compatibiliteit met uw huidige machines of besturingssystemen.
- Neem contact op via sale@etowonauto.com of +8617859788089 voor technische ondersteuning.
- Bekijk de leveringsopties, doorlooptijden en verzendvereisten.
- Volg de instructies van de fabrikant en de beste praktijken tijdens de installatie.
Verzending en Retourneren
Voorraadartikelen worden doorgaans dezelfde werkdag verzonden. Voor producten die momenteel niet op voorraad zijn, kunnen de verzendtijden variëren afhankelijk van de beschikbaarheid. Internationale verzending is mogelijk, en de verzendkosten worden berekend op basis van bestemming, gewicht en gekozen vervoerder.
Retourzendingen worden geaccepteerd binnen 30 dagen na ontvangst, mits de artikelen ongebruikt en in originele staat zijn. De kosten voor retourzending zijn voor rekening van de klant. Neem alstublieft contact met ons op voordat u een artikel retourneert om een retourautorisatie te ontvangen.
Voor meer details kunt u onze Verzend- en Retourbeleid raadplegen.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Snelle verzending
Originele onderdelen voor industriële automatisering beschikbaar voor snelle verzending wereldwijd.
-
Eenvoudige Retourzendingen
30 dagen retourrecht met 12 maanden garantie voor betrouwbare nazorgbescherming.
-
24/7 ondersteuning
Responsieve professionele ondersteuning om stabiele en efficiënte bedrijfsvoering te behouden.
-
Echt & Origineel
100% authentiek, rechtstreeks afkomstig van vertrouwde fabrikanten van industriële automatisering.
Technische & Koopgids
-
Can Converged PLC-DCS Architecture Cut Downtime by 22%?
This article examines how PLC-DCS convergence resolves the fragmentation bottleneck in legacy process plants. Drawing...
-
Retrofitting Mixed PLC & DCS Systems?
This article presents a hybrid protocol fusion architecture combining Modbus TCP and EtherNet/IP to overcome communic...
-
Original vs Compatible GE Fanuc PLC Parts?
This guide presents a data-driven methodology for identifying and verifying brand-new, original GE Fanuc 90-30, 90-70...
-
Can Data-Driven Alarm Grading Reduce Turbine Downtime?
This technical article presents a data-driven four-tier alarm grading strategy for Bently Nevada 3500 systems in comb...
-
How does ABB S800 I/O hot swap cut unplanned downtime by 90%?
This article presents quantified operational best practices for ABB S800 I/O hot swap in 24/7 process industries. ...
-
Is Your Refinery DCS Ready for Zero-Trust OT Access Control?
This technical article examines data-driven cybersecurity hardening strategies for Emerson DeltaV DCS in refiner...
