Transformeer je huis met de nieuwste multi-elektronica oplossingen, van intelligente verlichting tot spraakgestuurde apparaten, allemaal ontworpen om het leven gemakkelijker, veiliger en meer verbonden te maken.
SKU:1734-IT2I
Allen-Bradley 1734-IT2I | POINT I/O Isolated TC Module
Manufacturer: Allen-Bradley
Product No.: 1734-IT2I
Product Type: Input RTD Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 36g
Shipping port: Xiamen
Warranty: 12 months
Delen
- Snelle levering
- 24/7 Ondersteuning
- Kwaliteitsborging
Beschrijving
Product Overview
The Allen-Bradley 1734-IT2I is a POINT I/O isolated analog temperature input module with 2 differential, individually isolated thermocouple inputs. It delivers 15-bit resolution at 2.5 µV/count with a ±75 mV input voltage range. Weighing 0.08 pounds (0.036 kg), this open-style module requires no external DC power supply but installs only on the 1734-TBCJC wiring base assembly.
Technical Configuration
This module produces 8 bytes of scanner data (scanner Rx) and fault status data without consuming I/O data (scanner Tx). It supports signed integer data format with 4 temperature scales (Celsius, Fahrenheit, Kelvin, Rankine) plus 1 mV custom scale. Delta Sigma conversion ensures stable readings. Status indicators monitor network state, module state, input 0 state, and input 1 state in real time. The key switch position is 6.
Technical Specifications
| Parameter | Value |
|---|---|
| Manufacturer | Rockwell Automation |
| Brand | Allen-Bradley |
| Part Number | 1734-IT2I |
| Series | POINT I/O |
| Module Type | Analog Temperature Input Module |
| Inputs | 2 differential, individually isolated thermocouple |
| Resolution | 15 bits at 2.5 µV/cnt |
| Input Voltage | ±75 mV |
| Voltage Rating | 24V DC |
| POINTBus Current | 175 mA at 5V DC |
| Impedance / Resistance | 100 kΩ / 1 MΩ |
| Conversion Type | Delta Sigma |
| Data Format | Signed integer |
| Temperature Scales | Celsius, Fahrenheit, Kelvin, Rankine, plus 1 mV custom scale |
| Alarms | Under-range, over-range, CJC open-wire, level (low-low, low, high, high-high) |
| Power Dissipation | Max 1 Watt |
| Thermal Dissipation | Max 3.3 BTU/hour |
| Isolation Voltage | 50V continuous |
| Keyswitch Position | 6 |
| Wiring Base | 1734-TBCJC only |
| Dimensions (H x W x D) | 2.21 x 0.47 x 2.97 in |
| Weight | 0.08 lbs (0.036 kg) |
| Operating Temperature | -20 to 55°C |
| Storage Temperature | -4 to 85°C |
| Operating Vibration | 5 g at 10-500 Hz |
| Enclosure | Open style |
Installation Guide
Rotate the keyswitch to position 6 before installing the module. Mount only on the 1734-TBCJC wiring base assembly, which provides cold junction compensation. Wire thermocouple leads observing proper polarity for differential inputs. No external DC power supply is required. Configure the desired temperature scale (Celsius, Fahrenheit, Kelvin, Rankine) or mV custom scale, then enable alarm thresholds for under-range, over-range, and CJC open-wire detection.
Engineering Advantages
This module provides individually isolated differential thermocouple inputs, preventing ground loop interference between separate sensors. The 15-bit resolution at 2.5 µV/count enables detection of small temperature changes. CJC open-wire detection alerts operators to broken thermocouple circuits before process disruption. Four level alarms (low-low, low, high, high-high) support multi-stage process protection. The 8-byte scanner data output operates independently of I/O data consumption, simplifying configuration.
Technical FAQs
Q1: What type of inputs does the 1734-IT2I provide?
A1: This module provides 2 differential, individually isolated thermocouple inputs with ±75 mV range and 15-bit resolution at 2.5 µV/count.
Q2: What wiring base is required for this module?
A2: The 1734-IT2I installs only on the 1734-TBCJC wiring base assembly, which provides cold junction compensation.
Q3: What alarms does this module support?
A3: It provides under-range, over-range, CJC open-wire detection, and four level alarms (low-low, low, high, high-high).
Aanvullende specificaties
Scalar (V/f)
Vector
Op netstroom
Koopgids
- Bevestig het exacte model, onderdeelnummer en specificaties voordat u bestelt.
- Zorg voor compatibiliteit met uw huidige machines of besturingssystemen.
- Neem contact op via sale@etowonauto.com of +8617859788089 voor technische ondersteuning.
- Bekijk de leveringsopties, doorlooptijden en verzendvereisten.
- Volg de instructies van de fabrikant en de beste praktijken tijdens de installatie.
Verzending en Retourneren
Voorraadartikelen worden doorgaans dezelfde werkdag verzonden. Voor producten die momenteel niet op voorraad zijn, kunnen de verzendtijden variëren afhankelijk van de beschikbaarheid. Internationale verzending is mogelijk, en de verzendkosten worden berekend op basis van bestemming, gewicht en gekozen vervoerder.
Retourzendingen worden geaccepteerd binnen 30 dagen na ontvangst, mits de artikelen ongebruikt en in originele staat zijn. De kosten voor retourzending zijn voor rekening van de klant. Neem alstublieft contact met ons op voordat u een artikel retourneert om een retourautorisatie te ontvangen.
Voor meer details kunt u onze Verzend- en Retourbeleid raadplegen.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Snelle verzending
Originele onderdelen voor industriële automatisering beschikbaar voor snelle verzending wereldwijd.
-
Eenvoudige Retourzendingen
30 dagen retourrecht met 12 maanden garantie voor betrouwbare nazorgbescherming.
-
24/7 ondersteuning
Responsieve professionele ondersteuning om stabiele en efficiënte bedrijfsvoering te behouden.
-
Echt & Origineel
100% authentiek, rechtstreeks afkomstig van vertrouwde fabrikanten van industriële automatisering.
Technische & Koopgids
-
When Should You Replace a Yokogawa Analog IO Card?
This article breaks down Yokogawa analog AI/AO card calibration tolerances, drift aging benchmarks, and formal replac...
-
What Performance Gains Does S7-1500 Offer Over Legacy S7 PLCs?
Legacy Siemens S7-300 and S7-400 PLCs face spare-part shortages, rising failure rates and limited network capability,...
-
What Logic Changes Cut SIS False Trips by 94%?
This article examines practical logic modification and parameter tuning methods for ABB 800xA HI SIL3 safety ins...
-
Why Do FTE Redundancy Failovers Lock Up in DCS?
Honeywell FTE delivers sub-500 ms failover for Experion PKS, yet field records show 38% of outages stem from installa...
-
How Does the Bently Nevada 3500/42M Vibration Module Drift?
This technical guide examines the Bently Nevada 3500/42M vibration module within industrial automation architect...
-
What Causes IC694MDL Fault Codes in GE RX3i PLC Systems?
This guide explains GE RX3i IC694MDL discrete I/O fault codes, key electrical parameters, ESD and torque requirements...