Transformeer je huis met de nieuwste multi-elektronica oplossingen, van intelligente verlichting tot spraakgestuurde apparaten, allemaal ontworpen om het leven gemakkelijker, veiliger en meer verbonden te maken.
SKU:8440-1956
8440-1956 Woodward easYgen 3000 Engine Generator Control Module
Manufacturer: Woodward
Product No.: 8440-1956
Product Type: Operator Interface
Product Origin: USA
Payment:T/T, Western Union
Weight: 1850g
Shipping port: Xiamen
Warranty: 12 months
Delen
- Snelle levering
- 24/7 Ondersteuning
- Kwaliteitsborging
Beschrijving
Product Overview
The 8440-1956 (model designation: easYgen-3400-1-P1) is an engine generator controller engineered by Woodward Inc. as part of the easYgen-3000 series for complex breaker applications. Housed in a durable metal frame, this controller features a 1 A CT input, Accuracy Class 0.5 precision, and a multi-lingual display supporting 15 languages including English, German, Spanish, French, and Chinese. It provides comprehensive generator voltage monitoring (delta or wye configurations) with configurable A through F alarm classes. Weighing approximately 1.85 kg (4 lbs), the unit manages setting power ranges from 0.5 to 99,999.9 kW/kvar in critical generator management systems.
Core Technical Advantages
- Precision Power & Voltage Monitoring: Delivers Accuracy Class 0.5 measurement with configurable wye/delta voltage sensing to prevent earth faults.
- Multi-Lingual User Interface: Built-in display support for 15 international languages simplifies field operation and diagnostics worldwide.
- Flexible Alarm Management: Configurable alarm classes (A through F) allow precise threshold limit assignments and automated protective trip actions.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Brand & Manufacturer | Woodward Inc. |
| Product Series Family | easYgen-3000 Series |
| Part Number | 8440-1956 |
| Model Designation | easYgen-3400-1-P1 |
| Application Field | Engine Generator Control (Complex Breaker Applications) |
| Current Transformer (CT) Input | 1 A CT Input |
| Measurement Accuracy Class | Class 0.5 |
| Setting Power Range | 0.5 to 99,999.9 kW / kvar |
| Relay Contact Material | AgCdO (Silver Cadmium Oxide) |
| Alarm Configuration Classes | Classes A / B / C / D / E / F |
| Display Language Support | English, German, Spanish, French, Italian, Portuguese, Japanese, Chinese, Russian, Turkish, Polish, Slovakian, Finnish, Swedish |
| Enclosure Construction | Metal Frame Enclosure |
| Ambient Operating Humidity | 95%, non-condensing |
| Product Net Weight | Approx. 1.85 kg (1,850 g / 4 lbs) |
Industrial Applications
- Genset Power Generation: Manages complex breaker operations and synchronization for diesel and gas engine generators.
- Paralleling Control Systems: Coordinates load sharing and generator voltage/frequency matching across utility grids.
- Emergency Standby Power: Controls automatic transfer switches and utility protection in critical infrastructure facilities.
Wiring & Installation
- Panel Frame Inspection: Inspect metal housing for transit damage before mounting to prevent mechanical and frame grounding hazards.
- Voltage Sensing Setup: Wire generator voltage sensing in wye (phase-neutral) configuration for isolated networks to ensure earth-fault protection.
- CT & Contact Connections: Connect 1 A current transformer secondary loops and AgCdO relay contact outputs to specified control terminals.
Engineering Advantages
- Compact P1 Form Factor: Optimized panel footprint compared to P2 series modules while providing core generator control functionality.
- High-Durability Contacts: AgCdO contact materials deliver reliable switching endurance under continuous duty cycles.
- Solid Metal Housing: Structural metal frame provides EMI shielding and physical rigidity in generator enclosure panels.
Technical FAQs
Q1: What CT input rating does the Woodward 8440-1956 controller require?
A1: The module is designed specifically for 1 A secondary current transformer (CT) input connections.
Q2: How should voltage monitoring be configured for isolated networks?
A2: Voltage monitoring must be configured as wye (phase-neutral) in isolated networks to prevent earth faults from causing false trip actions.
Q3: What power setting range is supported by the easYgen-3400-1-P1?
A3: The controller supports a wide setting range from 0.5 to 99,999.9 kW/kvar.
Aanvullende specificaties
Scalar (V/f)
Vector
Op netstroom
Koopgids
- Bevestig het exacte model, onderdeelnummer en specificaties voordat u bestelt.
- Zorg voor compatibiliteit met uw huidige machines of besturingssystemen.
- Neem contact op via sale@etowonauto.com of +8617859788089 voor technische ondersteuning.
- Bekijk de leveringsopties, doorlooptijden en verzendvereisten.
- Volg de instructies van de fabrikant en de beste praktijken tijdens de installatie.
Verzending en Retourneren
Voorraadartikelen worden doorgaans dezelfde werkdag verzonden. Voor producten die momenteel niet op voorraad zijn, kunnen de verzendtijden variëren afhankelijk van de beschikbaarheid. Internationale verzending is mogelijk, en de verzendkosten worden berekend op basis van bestemming, gewicht en gekozen vervoerder.
Retourzendingen worden geaccepteerd binnen 30 dagen na ontvangst, mits de artikelen ongebruikt en in originele staat zijn. De kosten voor retourzending zijn voor rekening van de klant. Neem alstublieft contact met ons op voordat u een artikel retourneert om een retourautorisatie te ontvangen.
Voor meer details kunt u onze Verzend- en Retourbeleid raadplegen.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Snelle verzending
Originele onderdelen voor industriële automatisering beschikbaar voor snelle verzending wereldwijd.
-
Eenvoudige Retourzendingen
30 dagen retourrecht met 12 maanden garantie voor betrouwbare nazorgbescherming.
-
24/7 ondersteuning
Responsieve professionele ondersteuning om stabiele en efficiënte bedrijfsvoering te behouden.
-
Echt & Origineel
100% authentiek, rechtstreeks afkomstig van vertrouwde fabrikanten van industriële automatisering.
Technische & Koopgids
-
How Does GE Proficy HMI Design Cut Operator Response Time?
This article explains how field-proven GE Proficy HMI design principles, including tiered navigation, ISA 101 alarm c...
-
How Does ABB Cabinet FAT Cut Site Commissioning Risk?
This article explains how standardized ABB control cabinet assembly and factory acceptance testing reduce industrial ...
-
How Does Bently Nevada Balancing Stabilize Turbo Machinery?
This article explains how Bently Nevada TSI instruments enable practical field dynamic balancing for turbo machinery....
-
What Makes GE Historian Ideal for Industrial Time-Series Storage?
GE Historian delivers optimized long-term industrial time-series storage for control systems. It compresses OT data b...
-
How Do You Calibrate Honeywell Transmitters in Hazardous Areas?
This article explains how to calibrate Honeywell field instruments safely in hazardous areas, covering pre-calibratio...
-
How to Cut Bently Nevada TSI False Alarms on Compressor Skids?
This article explains how Bently Nevada TSI network layout affects compressor skid vibration monitoring reliability. ...