Transformeer je huis met de nieuwste multi-elektronica oplossingen, van intelligente verlichting tot spraakgestuurde apparaten, allemaal ontworpen om het leven gemakkelijker, veiliger en meer verbonden te maken.
SKU:6ES7432-1HF00-0AB0
6ES7432-1HF00-0AB0 Siemens S7-400 SM 432 Module
Manufacturer: Siemens
Product No.: 6ES7432-1HF00-0AB0
Product Type: Analog Output Module
Product Origin: DE
Payment:T/T, Western Union
Weight: 650g
Shipping port: Xiamen
Warranty: 12 months
Delen
- Snelle levering
- 24/7 Ondersteuning
- Kwaliteitsborging
Beschrijving
SIEMENS 6ES7432-1HF00-0AB0 SIMATIC S7-400 SM 432 Analog Output Module
The SIEMENS 6ES7432-1HF00-0AB0, also cataloged as the SM 432 Analog Output Module, operates as an isolated 8-channel output module with 13-bit resolution and voltage/current output ranges within SIMATIC S7-400 platforms.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 6ES7432-1HF00-0AB0 |
| Brand | Siemens |
| Product Type | SM 432 Analog Output Module |
| Series | SIMATIC S7-400 |
| Rated Load Voltage | 24 VDC |
| Reverse Polarity Protection | Yes |
| Current from L+ | 200 mA max (no load), 400 mA max (rated load) |
| Current from Backplane Bus | 150 mA max at 5 VDC |
| Power Loss | 9 W typ. |
| Analog Outputs | 8 |
| Resolution | 13 bit including sign |
| Conversion Time | 420 us per channel; 300 us in all ranges |
| Voltage Ranges | 0 to 10 V, 1 to 5 V, -10 V to +10 V |
| Current Ranges | 0 to 20 mA, -20 mA to +20 mA, 4 to 20 mA |
| Load Impedance (Voltage) | Min 1 kohm; capacitive load max 1 uF |
| Load Impedance (Current) | Max 500 ohm; 600 ohm with common-mode voltage below 1 V |
| Shielded Cable Length | Max 200 m |
| Dimensions (W x H x D) | 25 mm x 290 mm x 210 mm |
| Weight | 650 g (approx.) |
Output Ranges and Isolation Characteristics
Unit weight is approximately 650 g with dimensions of 25 mm width, 290 mm height, and 210 mm depth. The SM 432 provides 8 isolated analog outputs with 13-bit resolution including sign. Voltage output ranges are 0 to 10 V, 1 to 5 V, and -10 V to +10 V; current output ranges are 0 to 20 mA, -20 mA to +20 mA, and 4 to 20 mA. Voltage outputs are short-circuit protected with a maximum short-circuit current of 30 mA. Current outputs present a maximum no-load voltage of 19 V. Conversion time is 420 us per channel, with 300 us in all ranges. Settling time is 0.1 ms for resistive load, 3.5 ms for capacitive load, and 0.5 ms for inductive load. Operational error limit over the full temperature range is +/-0.5% for voltage and +/-1% for current. Basic error limit at 25 deg C is +/-0.5% for both voltage and current. Potential separation exists between the channels and the backplane bus, and between the channels and load voltage L+, but not between individual channels. Isolation is tested at 2120 VDC between bus and L+/M. No diagnostics function is provided.
Frequently Asked Questions
Q: What is the weight and physical size of the 6ES7432-1HF00-0AB0?
A: Approximately 650 g, with dimensions of 25 mm width, 290 mm height, and 210 mm depth.
Q: Are the analog output channels isolated from each other?
A: No. Potential separation is provided between the channels and the backplane bus and between the channels and load voltage L+, but not between individual channels.
Q: What load impedance does the module support for current and voltage outputs?
A: Voltage outputs require a minimum of 1 kohm with capacitive load up to 1 uF. Current outputs support a maximum of 500 ohm, or 600 ohm when common-mode voltage is reduced below 1 V.
Field Installation Guidelines
Insert the module into the S7-400 rack and secure the mounting screws. Verify 24 VDC load voltage polarity before energizing; reverse polarity protection is provided. Route shielded analog output cables to a maximum of 200 m, with the shield grounded at one end. Confirm load impedance for voltage outputs is at least 1 kohm and for current outputs does not exceed 500 ohm. Verify conversion time and settling time against the loop response requirements before commissioning. Confirm isolation ratings against the field circuit potential before wiring.
Aanvullende specificaties
Scalar (V/f)
Vector
Op netstroom
Koopgids
- Bevestig het exacte model, onderdeelnummer en specificaties voordat u bestelt.
- Zorg voor compatibiliteit met uw huidige machines of besturingssystemen.
- Neem contact op via sale@etowonauto.com of +8617859788089 voor technische ondersteuning.
- Bekijk de leveringsopties, doorlooptijden en verzendvereisten.
- Volg de instructies van de fabrikant en de beste praktijken tijdens de installatie.
Verzending en Retourneren
Voorraadartikelen worden doorgaans dezelfde werkdag verzonden. Voor producten die momenteel niet op voorraad zijn, kunnen de verzendtijden variëren afhankelijk van de beschikbaarheid. Internationale verzending is mogelijk, en de verzendkosten worden berekend op basis van bestemming, gewicht en gekozen vervoerder.
Retourzendingen worden geaccepteerd binnen 30 dagen na ontvangst, mits de artikelen ongebruikt en in originele staat zijn. De kosten voor retourzending zijn voor rekening van de klant. Neem alstublieft contact met ons op voordat u een artikel retourneert om een retourautorisatie te ontvangen.
Voor meer details kunt u onze Verzend- en Retourbeleid raadplegen.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Snelle verzending
Originele onderdelen voor industriële automatisering beschikbaar voor snelle verzending wereldwijd.
-
Eenvoudige Retourzendingen
30 dagen retourrecht met 12 maanden garantie voor betrouwbare nazorgbescherming.
-
24/7 ondersteuning
Responsieve professionele ondersteuning om stabiele en efficiënte bedrijfsvoering te behouden.
-
Echt & Origineel
100% authentiek, rechtstreeks afkomstig van vertrouwde fabrikanten van industriële automatisering.
Technische & Koopgids
-
Is Compact DCS Better Than PLC for Small Plants?
This article examines the ABB AC700F Freelance DCS as a compact control solution for small batch process plants ...
-
What Makes ControlEdge UCD Ideal for Water Treatment DCS?
Honeywell ControlEdge UCD DCS delivers DCS-grade reliability in a compact, PLC-like footprint suited to mid-size muni...
-
Why Is Redundant DCS Essential for 24/7 Process Automation?
ABB Freelance AC900F redundant DCS delivers hot standby CPU switching within 5 ms, hot-swappable S700 I/O, and verifi...
-
What Makes Honeywell C200 DCS Installation Standards So Critical?
This article examines Honeywell Experion PKS C200 DCS installation standards, key technical parameters, CPU and I/O f...
-
How Can You Avoid Hidden Faults in Logix5000 PLC Migration?
Allen-Bradley Logix5000 migration involves far more than a firmware flash. Version jumps from V20 to V30 can add 0.4 ...
-
How Do Thermal Stress and Aging Affect Ovation I/O Module Life?
This article explains how thermal stress, vibration and capacitor aging degrade Emerson Ovation I/O modules in power ...
