Transformeer je huis met de nieuwste multi-elektronica oplossingen, van intelligente verlichting tot spraakgestuurde apparaten, allemaal ontworpen om het leven gemakkelijker, veiliger en meer verbonden te maken.
SKU:6ES7313-1AD03-0AB0
6ES7313-1AD03-0AB0 Siemens S7-300 CPU 313 Original Stock
Manufacturer: Siemens
Product No.: 6ES7313-1AD03-0AB0
Product Type: CPU Module
Product Origin: DE
Payment:T/T, Western Union
Weight: 530g
Shipping port: Xiamen
Warranty: 12 months
Delen
- Snelle levering
- 24/7 Ondersteuning
- Kwaliteitsborging
Beschrijving
SIEMENS 6ES7313-1AD03-0AB0 SIMATIC S7-300 CPU 313
The SIEMENS 6ES7313-1AD03-0AB0, also cataloged as the 6ES7313-1AD03-0AB0 CPU 313, operates as a central processing unit with integrated 24 VDC power supply executing user logic within SIMATIC S7-300 platforms at 12 kbyte working memory.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 6ES7313-1AD03-0AB0 |
| Brand | Siemens |
| Product Type | CPU 313 Spare Part |
| Series | SIMATIC S7-300 |
| Rated Supply Voltage | 24 VDC |
| Permissible Range | 20.4 V to 28.8 VDC |
| Inrush Current | 8 A typ. |
| Power Loss | 8 W typ. |
| Work Memory | 12 kbyte integrated (12 KB / 4K instructions RAM) |
| Load Memory | FEPROM expandable to 4 Mbyte, integrated RAM 20 kbyte max |
| Backup | Battery (all blocks) or battery-free (72 bytes) |
| Bit Operation Time | 0.6 us typ., 1.2 us max |
| Word Operation Time | 2 us typ. |
| Fixed Point Arithmetic | 3 us typ. |
| Floating Point Arithmetic | 60 us typ. |
| Timer/Counter Operation | 15 us typ. |
| S7 Counters | 64 (35 retentive with or without battery) |
| S7 Timers | 128 (35 retentive with battery) |
| Flag Memory | 256 byte max (M 0.0 to M 71.7 retentive) |
| Digital Channels | 256 inputs, 256 outputs |
| Analog Channels | 64 inputs, 32 outputs |
| MPI Interface | 1 x MPI, max 32 nodes, 187.5 kbit/s max |
| Dimensions (W x H x D) | 80 mm x 125 mm x 130 mm |
| Weight | 530 g (approx.), memory card 16 g |
CPU Function and MPI Communication
Unit weight is approximately 530 g with dimensions of 80 mm width, 125 mm height, and 130 mm depth. The CPU 313 integrates a 24 VDC power supply and 12 kbyte working memory supporting 4K instructions. Load memory is expandable via Flash-EPROM to a maximum of 4 Mbyte, with 20 kbyte integrated RAM. Battery-backed backup retains all blocks; battery-free backup retains 72 bytes of memory bits, times, counters, and data. The integrated MPI interface supports up to 32 nodes at a maximum transmission rate of 187.5 kbit/s. Without repeaters, MPI cable length is limited to 50 m; with 2 repeaters, 1100 m; with 10 repeaters in series, 9100 m; via fiber optic cable, 23.8 km with 16 star hubs or OLMs. Per CPU, a maximum of 4 static and 4 dynamic connections are supported. Programming uses STEP 7 V5.0 or higher. Cycle time monitoring is adjustable from 1 ms to 6000 ms with a preset of 150 ms. SCL is supported as an optional programming language. User program protection via password is available.
Frequently Asked Questions
Q: What is the weight and physical size of the 6ES7313-1AD03-0AB0?
A: Approximately 530 g, with dimensions of 80 mm width, 125 mm height, and 130 mm depth. The memory card weighs approximately 16 g.
Q: What is the maximum MPI cable length supported by the CPU 313?
A: 50 m without repeaters, 1100 m with 2 repeaters, 9100 m with 10 repeaters in series, and 23.8 km via fiber optic cable with 16 star hubs or OLMs.
Q: What programming software is required for this CPU?
A: STEP 7 V5.0 or higher. SCL is supported as an optional programming language.
Field Installation Guidelines
Install the CPU in slot 2 of the S7-300 rail and secure the mounting screws. Verify 24 VDC supply polarity before energizing the backplane. Confirm STEP 7 V5.0 or higher is used for configuration. Route MPI cable within the calculated repeater limits for the required distance. Verify battery backup is installed if all blocks must be retained after power loss; otherwise only 72 bytes are retained without battery. Configure cycle time monitoring between 1 ms and 6000 ms based on the application scan time. Verify module bus connections to adjacent I/O modules after insertion.
Aanvullende specificaties
- DC-gevoed
- Modulair
Scalar (V/f)
Vector
Op netstroom
Koopgids
- Bevestig het exacte model, onderdeelnummer en specificaties voordat u bestelt.
- Zorg voor compatibiliteit met uw huidige machines of besturingssystemen.
- Neem contact op via sale@etowonauto.com of +8617859788089 voor technische ondersteuning.
- Bekijk de leveringsopties, doorlooptijden en verzendvereisten.
- Volg de instructies van de fabrikant en de beste praktijken tijdens de installatie.
Verzending en Retourneren
Voorraadartikelen worden doorgaans dezelfde werkdag verzonden. Voor producten die momenteel niet op voorraad zijn, kunnen de verzendtijden variëren afhankelijk van de beschikbaarheid. Internationale verzending is mogelijk, en de verzendkosten worden berekend op basis van bestemming, gewicht en gekozen vervoerder.
Retourzendingen worden geaccepteerd binnen 30 dagen na ontvangst, mits de artikelen ongebruikt en in originele staat zijn. De kosten voor retourzending zijn voor rekening van de klant. Neem alstublieft contact met ons op voordat u een artikel retourneert om een retourautorisatie te ontvangen.
Voor meer details kunt u onze Verzend- en Retourbeleid raadplegen.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Snelle verzending
Originele onderdelen voor industriële automatisering beschikbaar voor snelle verzending wereldwijd.
-
Eenvoudige Retourzendingen
30 dagen retourrecht met 12 maanden garantie voor betrouwbare nazorgbescherming.
-
24/7 ondersteuning
Responsieve professionele ondersteuning om stabiele en efficiënte bedrijfsvoering te behouden.
-
Echt & Origineel
100% authentiek, rechtstreeks afkomstig van vertrouwde fabrikanten van industriële automatisering.
Technische & Koopgids
-
What Logic Changes Cut SIS False Trips by 94%?
This article examines practical logic modification and parameter tuning methods for ABB 800xA HI SIL3 safety ins...
-
Why Do FTE Redundancy Failovers Lock Up in DCS?
Honeywell FTE delivers sub-500 ms failover for Experion PKS, yet field records show 38% of outages stem from installa...
-
How Does the Bently Nevada 3500/42M Vibration Module Drift?
This technical guide examines the Bently Nevada 3500/42M vibration module within industrial automation architect...
-
What Causes IC694MDL Fault Codes in GE RX3i PLC Systems?
This guide explains GE RX3i IC694MDL discrete I/O fault codes, key electrical parameters, ESD and torque requirements...
-
What CFC Rules Cut PCS7 Batch Abort Rates Fast?
This article presents enforceable CFC programming governance rules for Siemens PCS7 DCS batch plants, covering b...
-
What Makes the 1769-L3ER Ideal for Compact Skid Automation?
This guide explains how the Allen-Bradley 1769 CompactLogix L3ER bridges the gap between micro PLCs and large DC...