Transformeer je huis met de nieuwste multi-elektronica oplossingen, van intelligente verlichting tot spraakgestuurde apparaten, allemaal ontworpen om het leven gemakkelijker, veiliger en meer verbonden te maken.
SKU:6180W-12BPXP
6180W-12BPXP Allen-Bradley VersaView 1200W Workstation
Manufacturer: Allen-Bradley
Product No.: 6180W-12BPXP
Product Type: PanelView Plus Terminal
Product Origin: USA
Payment:T/T, Western Union
Weight: 19050g
Shipping port: Xiamen
Warranty: 12 months
Delen
- Snelle levering
- 24/7 Ondersteuning
- Kwaliteitsborging
Beschrijving
Product Overview
The 6180W-12BPXP is a highly integrated, heavy-duty 12.1-inch industrial workstation computer from the reliable VersaView 1200W product line manufactured by Allen-Bradley (Rockwell Automation). Designed to deliver stable plant-floor visualization and processing capability right at the machine level, this high-availability hardware platform features a rugged panel mount design with an integrated physical control keypad array. Encased in a massive, ultra-durable 19.05 kg (42.0 lbs) chassis measuring 19.01 x 12.25 x 11.70 inches, this specialized terminal features a universal wide-range 90 to 264V AC power supply block to ensure steady operation across unstable electrical grids.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Model Catalog Number | 6180W-12BPXP |
| Product Line Platform | Allen-Bradley VersaView 1200W Industrial Workstations |
| Screen Dimension & Type | 12.1-Inch Active-Matrix Color TFT LCD Matrix |
| Input Voltage Range | 90 to 264V AC (Autosensing, Single-Phase, 50/60 Hz) |
| Physical Mass Weight | 19.05 kg (42.0 lbs) heavy-duty structural frame |
| External Dimensions | 19.01 x 12.25 x 11.70 inches (Length x Width x Depth) |
| Operator Input Layout | Built-in front-panel rugged tactile alphanumeric keypad array |
| Mounting Configuration | Panel Mount (Flush-mount setup into NEMA/IP control cabinet doors) |
| Legacy OS Compatibility | Optimized for Windows XP Embedded / Professional system layers |
Industrial Solutions
- Legacy HMI Server Nodes: Acts as a direct host terminal for legacy supervisory control systems like FactoryTalk View ME/SE, running mission-critical process loops without software translation errors.
- Heavy Automotive Assembly Lines: Withstands the constant physical shock and severe kinetic forces of heavy machinery panels, thanks to its high-mass 19.05 kg structural frame.
- Chemical Batching Facilities: Protects processing applications from electrical line drops or localized voltage sags by leveraging its wide 90-264V AC power tolerance window.
- Outdoor Logistical Controls: Allows field operators wearing heavy industrial safety gloves to key in commands accurately via the deep-travel tactile front-bezel keypad buttons.
Wiring & Installation
Panel Cutout and Mechanical Bracing
Due to the substantial 19.05 kg (42.0 lbs) physical mass of this VersaView workstation, ensure the enclosure door or sub-panel has adequate structural reinforcement to prevent warping. Prepare a clean rectangular panel cutout that matches the unit's frame parameters, slide the computer in from the front, and tighten all rear panel-mounting clamps uniformly to establish a compressed, dust-tight environmental perimeter seal.
Power Termination and Isolation
Route the primary incoming AC line supply wires through dedicated liquid-tight conduit channels directly to the workstation's rear AC power receptacle block. The universal internal switching supply safely accommodates any single-phase utility voltage source spanning 90 to 264V AC. To ensure user safety and prevent data loss, verify that the primary ground terminal connects back to a low-impedance master ground bar.
Data Cable Routing Protocols
Isolate your network communication drops (such as serial links, peripheral connections, or coaxial lines) away from any high-current variable frequency drive (VFD) output runs or primary motor lines. Use high-flex shielded cables for data paths, and fasten the outer shield strain reliefs securely to the chassis frame to ground high-frequency noise spikes before they hit processing components.
Ventilation Clearance Criteria
Given the 11.70-inch deep chassis structure, maintain an open horizontal space profile of at least 3 inches behind the cooling fans and internal heatsink arrays to allow unobstructed airflow. Check that the ambient temperature inside the sealed control enclosure stays within manufacturer limits to extend the operational lifetime of the backlighting tubes and processor modules.
Engineering Advantages
- Embedded Keypad Redundancy: The physical front-panel keys provide a reliable backup input method, ensuring operators can manage processes safely even if wet surface conditions disrupt mouse or touch peripherals.
- Rugged Component Shielding: Built with deep internal shock mountings that shield delicate storage drives and processing boards from heavy machinery impacts.
- Direct Plant-Floor Mounting: The combination of an integrated display, computer, and key interface in one panel-mount housing eliminates the need for separate desktop enclosures or remote cabling networks.
Technical FAQs
Q1: What are the main benefits of using a 6180W unit featuring the built-in keypad instead of a touchscreen?
A1: Built-in tactile keypads provide mechanical feedback that touchscreens cannot, ensuring accurate entry in extreme environments. They remain functional when exposed to oil mist, water spray, splashes, or when technicians use heavy work gloves.
Q2: Why does this 12.1-inch industrial workstation weigh 19.05 kg (42 lbs)?
A2: The high-mass 19.05 kg profile is due to heavy industrial metal castings, a rugged frame, internal shock isolation dampeners, and heavy-duty electromagnetic shielding. This extreme build protects the PC against harsh, non-stop plant-floor vibrations.
Q3: Can the wide-range 90 – 264 Volts AC power supply handle nominal 120V and 240V grids?
A3: Yes. The advanced internal switching power supply automatically detects and adjusts to any voltage within the 90 to 264V AC window. This allows the computer to run globally on standard 115V AC or 230V AC lines without any manual jumper or switch modifications.
Aanvullende specificaties
Scalar (V/f)
Vector
Op netstroom
Koopgids
- Bevestig het exacte model, onderdeelnummer en specificaties voordat u bestelt.
- Zorg voor compatibiliteit met uw huidige machines of besturingssystemen.
- Neem contact op via sale@etowonauto.com of +8617859788089 voor technische ondersteuning.
- Bekijk de leveringsopties, doorlooptijden en verzendvereisten.
- Volg de instructies van de fabrikant en de beste praktijken tijdens de installatie.
Verzending en Retourneren
Voorraadartikelen worden doorgaans dezelfde werkdag verzonden. Voor producten die momenteel niet op voorraad zijn, kunnen de verzendtijden variëren afhankelijk van de beschikbaarheid. Internationale verzending is mogelijk, en de verzendkosten worden berekend op basis van bestemming, gewicht en gekozen vervoerder.
Retourzendingen worden geaccepteerd binnen 30 dagen na ontvangst, mits de artikelen ongebruikt en in originele staat zijn. De kosten voor retourzending zijn voor rekening van de klant. Neem alstublieft contact met ons op voordat u een artikel retourneert om een retourautorisatie te ontvangen.
Voor meer details kunt u onze Verzend- en Retourbeleid raadplegen.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Snelle verzending
Originele onderdelen voor industriële automatisering beschikbaar voor snelle verzending wereldwijd.
-
Eenvoudige Retourzendingen
30 dagen retourrecht met 12 maanden garantie voor betrouwbare nazorgbescherming.
-
24/7 ondersteuning
Responsieve professionele ondersteuning om stabiele en efficiënte bedrijfsvoering te behouden.
-
Echt & Origineel
100% authentiek, rechtstreeks afkomstig van vertrouwde fabrikanten van industriële automatisering.
Technische & Koopgids
-
What Makes 50ms Failover Critical for Industry 4.0 Smart Factories?
This article examines ABB DCS full-link redundancy design for pharmaceutical manufacturing under GMP and Industry 4.0...
-
Wat zijn de hoofdoorzaken van intermitterende TSI-communicatiefouten?
Dit artikel biedt een kwantitatieve probleemoplossingsmethode voor communicatieproblemen tussen GE Fanuc PLC en Bentl...
-
How to Secure Emerson DeltaV DCS Under Industry 4.0?
This article presents practical Emerson DeltaV DCS hardening strategies aligned with IEC 62443 standards for process ...
-
Is Your Metallurgical Plant Losing Millions to Hidden Energy Waste?
Metallurgical plants waste substantial energy due to fragmented PLC and DCS architectures that cannot share real-time...
-
How to Migrate GE Fanuc to Allen-Bradley Without Production Downtime?
This article provides a data-driven migration guide from GE Fanuc to Allen-Bradley PLCs for discrete manufacturing. I...
-
How Can Bently Nevada Kits Cut Centrifugal Machinery Downtime?
This article shows how Bently Nevada turnkey kits reduce unplanned downtime for centrifugal compressors and fans. It ...
