Transformeer je huis met de nieuwste multi-elektronica oplossingen, van intelligente verlichting tot spraakgestuurde apparaten, allemaal ontworpen om het leven gemakkelijker, veiliger en meer verbonden te maken.
SKU:CI862
3BUA000037R1 ABB CI862 Communication Module Master
Manufacturer: ABB
Product No.: CI862
Product Type: Communication Module
Product Origin: SE
Payment:T/T, Western Union
Weight: 700g
Shipping port: Xiamen
Warranty: 12 months
Delen
- Snelle levering
- 24/7 Ondersteuning
- Kwaliteitsborging
Beschrijving
Product Overview
The ABB CI862 (Article Number: 3BUA000037R1) is a high-performance communication interface module designed for the AC 800M controller series. This module specifically enables the integration of TRIO and Genius I/O systems into the modern 800xA control environment. By acting as a specialized master on the CEX-Bus, the CI862 provides a reliable migration path for legacy installations, allowing users to leverage advanced controller features while maintaining their existing field I/O infrastructure.
Technical Configuration
TRIO/Genius I/O Communication
The CI862 3BUA000037R1 is engineered to operate exclusively in Master mode. It manages the cyclic data exchange between the AC 800M processor and Genius I/O blocks or TRIO racks. This interface ensures high-speed synchronization and robust data integrity, making it a critical component for plants that rely on TRIO bus technology for remote field distribution.
CEX-Bus Scalability
As a CEX-Bus module, the CI862 mounts directly to the side of the AC 800M controller or on a CEX-Bus expansion unit. Its compact design allows for multiple communication interfaces to be housed in a single rack, providing the flexibility needed to handle complex, multi-protocol industrial networks without expanding the cabinet footprint significantly.
Reliability and Lifecycle Status
Currently designated with a "Classic" lifecycle status, the 3BUA000037R1 remains a vital spare part and expansion module for established industrial sites. It is built to withstand demanding storage and operating conditions, featuring a wide storage temperature range and high tolerance for non-condensing humidity, ensuring long-term hardware availability for critical infrastructure.
Technical Specifications
| Parameter | Specification |
|---|---|
| Model Number | CI862 3BUA000037R1 |
| Manufacturer | ABB |
| Series | AC 800M |
| Communication Protocol | TRIO / Genius I/O |
| Operational Mode | Master |
| Operating Humidity | 5% to 95% (Non-condensing) |
| Storage Temperature | -40°C to +70°C |
| Lifecycle Status | Classic |
| Weight | 0.7 kg (1.5 lbs) |
| Compliance | CE-marked, WEEE Directive |
Installation & Maintenance Guide
Module Mounting
The CI862 3BUA000037R1 should be installed on the CEX-Bus with the controller powered down unless the specific baseplate supports hot-swap procedures. Proper grounding of the CEX-Bus and the TRIO network cable shield is essential to prevent electromagnetic interference from affecting signal quality.
Network Configuration
Configuration of the Genius/TRIO network is performed through the ABB Engineering Suite. Engineers must define the baud rate and device addresses within the control software to match the physical hardware settings of the field I/O blocks to ensure successful communication established by the master module.
Engineering Advantages
Seamless Legacy Integration
The primary advantage of the CI862 is its ability to bridge the gap between legacy TRIO I/O hardware and the contemporary AC 800M control logic. This eliminates the need for full system "rip-and-replace" upgrades, allowing for incremental modernization that minimizes downtime and capital expenditure.
Standardized Compliance
Adhering to CE marking and the WEEE Directive 2012/19/EU, the module meets stringent European safety and environmental standards. This compliance ensures that the hardware is suitable for global deployment in regulated industries, including power generation, water treatment, and chemical processing.
Technical FAQs
Q1: Can the CI862 be used as a Slave device?
A1: No, the 3BUA000037R1 is designed to operate strictly in Master mode to control the TRIO/Genius I/O bus.
Q2: What is the significance of the "Classic" lifecycle status?
A2: "Classic" status means the product is no longer in active volume production but is fully supported with spare parts, maintenance, and technical assistance by ABB.
Q3: Is there a specific mounting orientation required?
A3: The module should be mounted vertically on a standard DIN rail via the AC 800M CEX-Bus base to ensure optimal heat dissipation and secure electrical connection.
Aanvullende specificaties
Scalar (V/f)
Vector
Op netstroom
Koopgids
- Bevestig het exacte model, onderdeelnummer en specificaties voordat u bestelt.
- Zorg voor compatibiliteit met uw huidige machines of besturingssystemen.
- Neem contact op via sale@etowonauto.com of +8617859788089 voor technische ondersteuning.
- Bekijk de leveringsopties, doorlooptijden en verzendvereisten.
- Volg de instructies van de fabrikant en de beste praktijken tijdens de installatie.
Verzending en Retourneren
Voorraadartikelen worden doorgaans dezelfde werkdag verzonden. Voor producten die momenteel niet op voorraad zijn, kunnen de verzendtijden variëren afhankelijk van de beschikbaarheid. Internationale verzending is mogelijk, en de verzendkosten worden berekend op basis van bestemming, gewicht en gekozen vervoerder.
Retourzendingen worden geaccepteerd binnen 30 dagen na ontvangst, mits de artikelen ongebruikt en in originele staat zijn. De kosten voor retourzending zijn voor rekening van de klant. Neem alstublieft contact met ons op voordat u een artikel retourneert om een retourautorisatie te ontvangen.
Voor meer details kunt u onze Verzend- en Retourbeleid raadplegen.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Snelle verzending
Originele onderdelen voor industriële automatisering beschikbaar voor snelle verzending wereldwijd.
-
Eenvoudige Retourzendingen
30 dagen retourrecht met 12 maanden garantie voor betrouwbare nazorgbescherming.
-
24/7 ondersteuning
Responsieve professionele ondersteuning om stabiele en efficiënte bedrijfsvoering te behouden.
-
Echt & Origineel
100% authentiek, rechtstreeks afkomstig van vertrouwde fabrikanten van industriële automatisering.
Technische & Koopgids
-
Can Converged PLC-DCS Architecture Cut Downtime by 22%?
This article examines how PLC-DCS convergence resolves the fragmentation bottleneck in legacy process plants. Drawing...
-
Retrofitting Mixed PLC & DCS Systems?
This article presents a hybrid protocol fusion architecture combining Modbus TCP and EtherNet/IP to overcome communic...
-
Original vs Compatible GE Fanuc PLC Parts?
This guide presents a data-driven methodology for identifying and verifying brand-new, original GE Fanuc 90-30, 90-70...
-
Can Data-Driven Alarm Grading Reduce Turbine Downtime?
This technical article presents a data-driven four-tier alarm grading strategy for Bently Nevada 3500 systems in comb...
-
How does ABB S800 I/O hot swap cut unplanned downtime by 90%?
This article presents quantified operational best practices for ABB S800 I/O hot swap in 24/7 process industries. ...
-
Is Your Refinery DCS Ready for Zero-Trust OT Access Control?
This technical article examines data-driven cybersecurity hardening strategies for Emerson DeltaV DCS in refiner...