330903-00-03-10-02-05 Bently Nevada 3300 NSv ClickLoc Probe
Manufacturer: Bently Nevada
Product No.: 330903-00-03-10-02-05
Product Type: 3300 NSv Probe
Product Origin: USA
Payment:T/T, Western Union
Weight: 110g
Shipping port: Xiamen
Warranty: 12 months
Delen
- Snelle levering
- 24/7 Ondersteuning
- Kwaliteitsborging
Beschrijving
Bently Nevada 330903-00-03-10-02-05 3300 NSv Proximity Probe
Bently Nevada 330903-00-03-10-02-05 is a 3300 NSv proximity probe with M8x1 thread, without armor. Features 30mm overall case length, 1.0 meter total length, and miniature coaxial ClickLoc connector with standard cable. Multiple agency approvals included. Weight: 0.11 kg (0.24 lbs).
Technical Specifications
| Parameter | Specification |
| Manufacturer | Bently Nevada |
| Model | 330903-00-03-10-02-05 |
| Probe Type | 3300 NSv Proximity Probe, M8x1 thread, without armor |
| Unthreaded Length | 00 mm |
| Overall Case Length | 30 mm |
| Total Length | 1.0 meter (39 inches) |
| Connector Type | Miniature coaxial ClickLoc connector, standard cable |
| Agency Approval | Multiple Approvals (Option 05) |
| Weight | 0.11 kg (0.24 lbs) |
| Probe DC Resistance (1.0m) | 4.2 ± 0.5 ohms |
| Linear Range | 1.5 mm (60 mils) from 0.25 to 1.75 mm |
| Recommended Gap Setting | 1.0 mm (40 mils) |
| Incremental Scale Factor | 7.87 V/mm (200 mV/mil) +12.5%/-20% |
| Deviation from Best Fit Line | Less than ±0.06 mm (±2.3 mils) |
| Frequency Response | 0 to 10 kHz with 305m field wiring |
| Probe Tip Material | Polyphenylene sulfide (PPS) |
| Probe Case Material | AISI 304 stainless steel |
| Operating Temperature | -52°C to +177°C (-62°F to +351°F) |
| Storage Temperature | -52°C to +177°C (-62°F to +351°F) |
| Minimum Bend Radius | 25.4 mm (1.0 inch) |
| Recommended Torque | Finger tight, max 0.56 N·m (5 in·lb) |
| Minimum Target Diameter | 8.9 mm (0.35 inch) |
Extension Cable Specifications
| Parameter | Specification |
| Center Conductor DC Resistance | 0.220 Ω/m (0.067 Ω/ft) |
| Shield DC Resistance | 0.066 Ω/m (0.020 Ω/ft) |
| Extension Cable Capacitance | 69.9 pF/m (21.3 pF/ft) typical |
| Maximum Field Wiring Length | 305 meters (1,000 feet) |
Key Features
- 35% higher chemical resistance than 3300 RAM probes for process compressor applications
- Mechanically and electrically compatible with previous 3300 RAM probes
- Superior side-view characteristics compared to 3000-series 190 probe
- Viton O-ring seals differential pressure between probe tip and case
- 75 ohm coaxial FEP insulated cable
- Field wiring supports 16 to 24 AWG with three-conductor shielded triad cable
Installation Guidelines
Probe Case Torque: Maximum rated torque for M8x1 probe cases is 7.3 N·m (65 in·lb). Recommended torque is 5.1 N·m (45 in·lb). Maximum thread engagement length is 12 mm.
Connector Torque: Finger tight maximum. Do not exceed 0.56 N·m (5 in·lb).
Minimum Bend Radius: 25.4 mm (1.0 inch) with or without stainless steel armor.
Gap Setting: Recommended gap is 1.0 mm (40 mils). Linear range begins at approximately 0.25 mm (10 mils) from target.
Field Wiring: 24-16 AWG recommended. Maximum cable length of 305 meters (1,000 feet) between Proximitor Sensor and monitor.
FAQs
Q1. Is the 330903-00-03-10-02-05 compatible with existing 3300 RAM systems?
A1. Yes. The 3300 NSv probe and extension cable are mechanically and electrically compatible and interchangeable with Bently Nevada's previous 3300 RAM proximity probe and extension cable.
Q2. What is the maximum field wiring distance from Proximitor Sensor to monitor?
A2. Maximum length is 305 meters (1,000 feet) between the 3300 XL NSv Proximitor Sensor and the monitor. Frequency response remains 0 to 10 kHz with this length.
Q3. Are the probes pressure tested before shipment?
A3. No. Probes are not pressure tested prior to shipment. The sealing material consists of a Viton O-ring. Contact the custom design department if pressure seal testing is required for your application.
Aanvullende specificaties
Scalar (V/f)
Vector
Op netstroom
Koopgids
- Bevestig het exacte model, onderdeelnummer en specificaties voordat u bestelt.
- Zorg voor compatibiliteit met uw huidige machines of besturingssystemen.
- Neem contact op via sale@etowonauto.com of +8617859788089 voor technische ondersteuning.
- Bekijk de leveringsopties, doorlooptijden en verzendvereisten.
- Volg de instructies van de fabrikant en de beste praktijken tijdens de installatie.
Verzending en Retourneren
Voorraadartikelen worden doorgaans dezelfde werkdag verzonden. Voor producten die momenteel niet op voorraad zijn, kunnen de verzendtijden variëren afhankelijk van de beschikbaarheid. Internationale verzending is mogelijk, en de verzendkosten worden berekend op basis van bestemming, gewicht en gekozen vervoerder.
Retourzendingen worden geaccepteerd binnen 30 dagen na ontvangst, mits de artikelen ongebruikt en in originele staat zijn. De kosten voor retourzending zijn voor rekening van de klant. Neem alstublieft contact met ons op voordat u een artikel retourneert om een retourautorisatie te ontvangen.
Voor meer details kunt u onze Verzend- en Retourbeleid raadplegen.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Snelle verzending
Originele onderdelen voor industriële automatisering beschikbaar voor snelle verzending wereldwijd.
-
Eenvoudige Retourzendingen
30 dagen retourrecht met 12 maanden garantie voor betrouwbare nazorgbescherming.
-
24/7 ondersteuning
Responsieve professionele ondersteuning om stabiele en efficiënte bedrijfsvoering te behouden.
-
Echt & Origineel
100% authentiek, rechtstreeks afkomstig van vertrouwde fabrikanten van industriële automatisering.
Technische & Koopgids
-
What Makes 50ms Failover Critical for Industry 4.0 Smart Factories?
This article examines ABB DCS full-link redundancy design for pharmaceutical manufacturing under GMP and Industry 4.0...
-
Wat zijn de hoofdoorzaken van intermitterende TSI-communicatiefouten?
Dit artikel biedt een kwantitatieve probleemoplossingsmethode voor communicatieproblemen tussen GE Fanuc PLC en Bentl...
-
How to Secure Emerson DeltaV DCS Under Industry 4.0?
This article presents practical Emerson DeltaV DCS hardening strategies aligned with IEC 62443 standards for process ...
-
Is Your Metallurgical Plant Losing Millions to Hidden Energy Waste?
Metallurgical plants waste substantial energy due to fragmented PLC and DCS architectures that cannot share real-time...
-
How to Migrate GE Fanuc to Allen-Bradley Without Production Downtime?
This article provides a data-driven migration guide from GE Fanuc to Allen-Bradley PLCs for discrete manufacturing. I...
-
How Can Bently Nevada Kits Cut Centrifugal Machinery Downtime?
This article shows how Bently Nevada turnkey kits reduce unplanned downtime for centrifugal compressors and fans. It ...