Forvandle hjemmet ditt med de nyeste multi-elektroniske løsningene, fra intelligent belysning til stemmestyrte enheter – alle designet for å gjøre livet enklere, tryggere og mer tilkoblet. Optimaliser driften med Bently Nevada 3500 overvåkingssystem, som tilbyr sanntids vibrasjons- og maskintilstandsovervåking for å forhindre feil og maksimere oppetid.
SKU:VFD022EL21A
VFD022EL21A Delta Electronics 11A Single-Phase Micro Drive
Manufacturer: Delta
Product No.: VFD022EL21A
Product Type: AC Drive
Product Origin: CN
Payment:T/T, Western Union
Weight: 1400g
Shipping port: Xiamen
Warranty: 12 months
Del
- Rask levering
- 24/7 kundestøtte
- Kvalitetssikring
Beskrivelse
Product Overview
The Delta Electronics VFD022EL21A is a commercial-grade, multi-functional micro AC inverter from the high-reliability VFD-EL series. Engineered to support standard induction motor assets up to 3 Horsepower (2.2 kW), this compact variable frequency drive features a convenient single-phase 230V input line configuration that outputs a balanced 3-phase current rated at 11 Amps. Optimized for tight panel footprints and streamlined installation, it incorporates a built-in digital operating keypad, side-by-side DIN-rail mounting capabilities, and an integrated dynamic braking chopper circuit. Relying on an advanced open-loop V/Hz scalar control module, the VFD022EL21A provides exceptionally smooth speed regulation and energy savings for mechanical fans, water pumps, conveyor systems, and dedicated packaging machines.
Core Technical Advantages
Stable Volts-per-Hertz Scalar Control
Operating on a standard open-loop V/Hz tracking profile, the drive supplies reliable voltage-to-frequency proportional output curves. This makes it an exceptionally efficient option for variable and constant torque loads that do not require complex, encoder-based closed-loop response networks.
Internal Dynamic Braking Chopper
A factory-integrated dynamic braking transistor comes standard on the internal power card. When connected to a compatible external power dissipation resistor, the drive effectively prevents overvoltage faults caused by high-inertia regenerative loads during aggressive deceleration cycles.
Onboard Digital User Interface
The drive features factory-integrated operator controls positioned directly on its front panel. This clear digital setup eliminates the need to source standalone keypads, allowing plant operators to quickly adjust frequency parameters, map digital I/O lines, and review active fault logs.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Manufacturer | Delta Electronics |
| Model Number | VFD022EL21A |
| Power Specifications | 3 HP / 2.2 kW (Constant Torque capacity) |
| Main Input Power | 1-Phase, 200V to 240V AC incoming spectrum |
| Output Amperage | 11 Amps maximum continuous output current |
| Peak Output Frequency | 0.1 to 600 Hz customizable operation bounds |
| Mechanical Classification | Frame Size B | IP20 ingress protection rating |
| Chassis Dimensions | 6.85 x 3.94 x 5.35 Inches (H x W x D) |
| Net Weight | 1.4 kg (3.09 lbs) nominal physical weight |
Installation and Maintenance
Frame Size B Spacing Clearances
The Frame B chassis features standard physical constraints of 6.85 x 3.94 x 5.35 inches and carries a net weight of approximately 1.4 kg (3.09 lbs). This compact footprint allows for easy DIN-rail attachment. Ensure you leave adequate open space above and below the cooling heatsinks to allow proper air passage inside the enclosure.
Single-Phase Input Power Termination
The incoming single-phase 200–240 V AC supply utility wires should be terminated exclusively onto the primary L1 and L2 terminals. Do not attach any incoming hot source wires onto terminals U, V, or W, as these are dedicated output vectors for supplying balanced 3-phase current to the induction motor.
Environmental Ingress Considerations
This micro inverter features a stock IP20 open-chassis rating and lacks environmental moisture seals. For machine configurations located in zones exposed to oil residue, conductive metal dust, or water spray, ensure the drive is installed inside a sealed secondary electrical cabinet (NEMA 12 or IP54).
Engineering Advantages
High-Frequency Processing Window
Capable of tracking and maintaining output currents up to a high frequency limit of 600 Hz, the VFD022EL21A easily manages specialized high-speed machinery assets, such as wood woodworking spindles, chemical mixers, and processing separators.
Programmable DC Injection Braking
The integrated DC injection control logic enables developers to apply a stationary DC magnetic field across the motor windings. This function provides holding torque to prevent mechanical drift on ventilation fans or heavily loaded conveyor setups prior to active motor acceleration.
Dense Side-by-Side Installation
The streamlined physical layout of the VFD-EL platform allows for adjacent, high-density side-by-side drive clusters on a single control rail. This layout significantly reduces required cabinet enclosure sizes and associated infrastructure costs.
Technical FAQs
Q1: Can I operate the VFD022EL21A drive by feeding it a standard 3-phase AC input?
A1: No, the VFD022EL21A is engineered exclusively for a single-phase 200–240 V AC input line. The internal rectifier circuit converts this single-phase source to provide a standard 3-phase variable frequency output for 3-phase induction motors.
Q2: What is the primary difference between Delta's VFD-E and VFD-EL drive series?
A2: The VFD-EL family is a cost-effective micro drive line that utilizes V/Hz scalar control alongside a built-in digital operating interface. The VFD-E series is a modular vector micro drive platform that provides open-loop vector tracking and supports plug-in expansion cards.
Q3: Is the dynamic braking resistor pre-installed inside the Frame B chassis?
A3: The unit contains the internal dynamic braking control circuit (chopper), but the heavy-duty power resistor itself is an external accessory. To enable active dynamic braking on high-inertia loads, you must size and install an external braking resistor separately.
Commercial Contact Email: sale@etowonauto.com
Ytterligere spesifikasjoner
- Svart
- Grå
Skalar (V/f)
Vektor
AC-drevet
Kjøpsveiledning
- Bekreft nøyaktig modell, delenummer og spesifikasjoner før bestilling.
- Sørg for kompatibilitet med ditt nåværende maskineri eller kontrollsystemer.
- Ta kontakt via sale@etowonauto.com eller +8617859788089 for teknisk assistanse.
- Gå gjennom leveringsalternativer, leveringstider og fraktkrav.
- Følg produsentens instruksjoner og beste praksis under installasjon.
Frakt og retur
Varer på lager sendes vanligvis samme virkedag. For produkter som ikke er på lager for øyeblikket, kan leveringstiden variere basert på tilgjengelighet. Internasjonal frakt er tilgjengelig, og fraktkostnader beregnes ut fra destinasjon, vekt og valgt transportør.
Returer godtas innen 30 dager etter mottak, forutsatt at varene er ubrukte og i original stand. Returfraktkostnader dekkes av kunden. Vennligst kontakt oss før du returnerer en vare for å få returautorisasjon.
For mer informasjon, vennligst se vår Frakt- og returpolicy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Rask levering
Originale deler til industriell automasjon tilgjengelig for rask levering over hele verden.
-
Enkel retur
30 dagers returrett med 12 måneders garanti for pålitelig etterkjøpsbeskyttelse.
-
24/7 støtte
Responsiv profesjonell støtte for å hjelpe med å opprettholde stabile og effektive operasjoner.
-
Ekte og original
100 % autentisk, hentet direkte fra pålitelige produsenter av industriell automasjon.
Teknisk og kjøpsguide
-
Kan adaptiv PLC-arkitektur løse flaskehalser i fleksibel produksjon?
Tradisjonelle faste logikk-PLC-er forårsaker 15-25 % nedetid under produksjonsomstillinger. Adaptiv PLC-arkitektur in...
-
Hvordan redusere igangkjøringstid for tverrmerke drivverk med 85 %?
Denne artikkelen forklarer hvordan ABB ACS880-frekvensomformere med innebygd EtherNet/IP-protokoll eliminerer behovet...
-
Hva er de skjulte kostnadene ved aldrende PLC- og DCS-infrastruktur?
Over 60 % av globale prosessanlegg er fortsatt avhengige av DCS-systemer som er eldre enn 15 år, og står overfor mang...
-
Hvorfor skyldes 62 % av farmasøytiske feil kontrollmangler?
Denne artikkelen undersøker hvordan Emerson DeltaV Batch DCS løser GMP-overholdelse og effektivitetshull i farmasøyti...
-
Hvorfor opplever fortsatt over 44 % av anleggene månedlige utstyrsavbrudd?
Uplanlagte nedstengninger av turboladere koster anlegg opptil 636 000 dollar per time. Standard PLC- og DCS-systemer ...
-
Er ditt industrielle automasjonssystem virkelig feiltolerant?
Denne tekniske artikkelen kvantifiserer hvordan Allen‑Bradleys to-nivås PLC-redundans oppnår 99,99 % årlig oppetid me...