Forvandle hjemmet ditt med de nyeste multi-elektroniske løsningene, fra intelligent belysning til stemmestyrte enheter – alle designet for å gjøre livet enklere, tryggere og mer tilkoblet. Optimaliser driften med Bently Nevada 3500 overvåkingssystem, som tilbyr sanntids vibrasjons- og maskintilstandsovervåking for å forhindre feil og maksimere oppetid.
SKU:TSXASY410
Schneider Electric TSXASY410 4 Channel Analog Output
Manufacturer: Schneider
Product No.: TSXASY410
Product Type: Analog Output Module
Product Origin: FR
Payment:T/T, Western Union
Weight: 350g
Shipping port: Xiamen
Warranty: 12 months
Del
- Rask levering
- 24/7 kundestøtte
- Kvalitetssikring
Beskrivelse
Schneider Electric TSXASY410 Modicon Analog Output Module
Schneider Electric TSXASY410 | Analog output module for the Modicon Premium and TSX Micro automation platforms. Provides 4 analog output channels with selectable current (0-20 mA, 4-20 mA) or voltage (±10 V) output. 1500 Vrms channel-to-channel and channel-to-bus isolation. Screw terminal block connection. Weight: 0.35 kg (0.77 lb).
Key Features
4 analog output channels. Selectable current (0-20 mA, 4-20 mA) or voltage (±10 V) output. 11-bit + sign analog/digital conversion. 2.5 ms conversion time. 10.25 µA resolution (current), 5.12 mV resolution (voltage). 1500 Vrms isolation between channels and bus. Overload and short-circuit protection. Screw terminal block connection. CE marked. Made in France.
Technical Specifications
| Manufacturer | Schneider Electric |
| Part Number | TSXASY410 |
| Product Line | TSX Micro PLCs / Modicon Premium |
| Product Type | Analog Output Module |
| Number of Channels | 4 |
| Output Type | Current 0-20 mA, 4-20 mA; Voltage ±10 V |
| Analog/Digital Conversion | 11 bits + sign |
| Conversion Time | 2.5 ms |
| Resolution | 10.25 µA (current); 5.12 mV (voltage) |
| Measurement Error (25°C) | 0.45% FS (±10V); 0.52% FS (0-20mA/4-20mA) |
| Measurement Error (0-60°C) | 0.75% FS (±10V); 0.98% FS (0-20mA/4-20mA) |
| Isolation (Channel to Channel) | 1500 Vrms |
| Isolation (Channel to Bus) | 1500 Vrms |
| Isolation (Channel to Ground) | 500 V |
| Load Impedance (Current) | < 600 Ω (0-20 mA, 4-20 mA) |
| Load Impedance (Voltage) | > 1000 Ω (±10 V) |
| Max Load Inductance | 300 µH |
| Max Load Capacitance | 0.1 µF |
| Output Voltage Limit | ≤ 30 V |
| Current Consumption | 900 mA @ 5V DC |
| Power Supply | 24V DC |
| Power Consumption | 3 W |
| Electrical Connection | Screw terminal block |
| Protection | Overload, short-circuit |
| Dimensions (W x H x D) | 125 x 100 x 40 mm |
| Net Weight | 0.35 kg (0.77 lb) |
| IP Degree of Protection | IP20 |
| Pollution Degree | 2 |
| Operating Temperature | 0°C to +60°C |
| Storage Temperature | -25°C to +70°C |
| Relative Humidity | 10-95% (operation); 5-95% (storage), non-condensing |
| Operating Altitude | 0-2000 m |
| Certifications | CE, UL 508, CSA, IEC 61131-2, GL, ABS, RINA, DNV |
| Country of Origin | France |
Installation Notes
Mount in Modicon Premium or TSX Micro PLC rack. Connect field wiring via screw terminal block. Use shielded cable for analog signals and connect shields to the designated shield terminals. Observe load impedance limits: <600 Ω for current output, >1000 Ω for voltage output. Maintain IP20 enclosure and pollution degree 2 environment. Ensure operating temperature remains between 0°C and 60°C.
Engineering Advantages
Selectable current or voltage output on each channel provides application flexibility. 1500 Vrms channel-to-channel isolation protects against ground loops and noise. High 11-bit + sign resolution ensures precise analog control. Overload and short-circuit protection safeguard the module and connected equipment. Compact 0.35 kg design saves panel space. Marine certifications (GL, ABS, RINA, DNV) enable use in shipboard and offshore applications.
FAQs
Q1: What output types are available?
A1: Current (0-20 mA, 4-20 mA) and voltage (±10 V).
Q2: What is the isolation rating?
A2: 1500 Vrms between channels and bus, 500 V between channels and ground.
Q3: What is the power consumption?
A3: 3 W at 24V DC supply, with 900 mA current consumption at 5V DC.
Ytterligere spesifikasjoner
Skalar (V/f)
Vektor
AC-drevet
Kjøpsveiledning
- Bekreft nøyaktig modell, delenummer og spesifikasjoner før bestilling.
- Sørg for kompatibilitet med ditt nåværende maskineri eller kontrollsystemer.
- Ta kontakt via sale@etowonauto.com eller +8617859788089 for teknisk assistanse.
- Gå gjennom leveringsalternativer, leveringstider og fraktkrav.
- Følg produsentens instruksjoner og beste praksis under installasjon.
Frakt og retur
Varer på lager sendes vanligvis samme virkedag. For produkter som ikke er på lager for øyeblikket, kan leveringstiden variere basert på tilgjengelighet. Internasjonal frakt er tilgjengelig, og fraktkostnader beregnes ut fra destinasjon, vekt og valgt transportør.
Returer godtas innen 30 dager etter mottak, forutsatt at varene er ubrukte og i original stand. Returfraktkostnader dekkes av kunden. Vennligst kontakt oss før du returnerer en vare for å få returautorisasjon.
For mer informasjon, vennligst se vår Frakt- og returpolicy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Rask levering
Originale deler til industriell automasjon tilgjengelig for rask levering over hele verden.
-
Enkel retur
30 dagers returrett med 12 måneders garanti for pålitelig etterkjøpsbeskyttelse.
-
24/7 støtte
Responsiv profesjonell støtte for å hjelpe med å opprettholde stabile og effektive operasjoner.
-
Ekte og original
100 % autentisk, hentet direkte fra pålitelige produsenter av industriell automasjon.
Teknisk og kjøpsguide
-
What Makes Emerson DeltaV M-Series Ideal for Oil & Gas DCS Control?
Emerson's DeltaV M-Series controller delivers reliable regulatory control for oil and gas assets through MQ and MX va...
-
What Makes Siemens PCS 7 AS410 Ideal for Chemical DCS?
Siemens PCS 7 with the AS410 automation station delivers high availability for continuous chemical manufacturing. Thi...
-
What Causes Most ABB AC800M Migration Failures?
ABB AC800M controllers have run for 12 to 18 years in many plants, and spare part lead times now reach 16 weeks. This...
-
How to Migrate Honeywell TDC3000 to Experion PKS?
This guide explains how process plants can migrate aging Honeywell TDC3000 DCS systems to Experion PKS C300 through p...
-
What Makes PLC and DCS Migration Projects Succeed?
Multi-vendor control system migration demands disciplined project management, early interface testing, and structured...
-
How Does GE OPC UA Server Connect Mixed PLC and DCS Systems?
GE OPC UA server helps industrial plants unify fragmented PLC and DCS data through a vendor-neutral standard, coverin...
