Forvandle hjemmet ditt med de nyeste multi-elektroniske løsningene, fra intelligent belysning til stemmestyrte enheter – alle designet for å gjøre livet enklere, tryggere og mer tilkoblet. Optimaliser driften med Bently Nevada 3500 overvåkingssystem, som tilbyr sanntids vibrasjons- og maskintilstandsovervåking for å forhindre feil og maksimere oppetid.
SKU:140DAO84010
Schneider Electric 140DAO84010 Modicon Quantum 16-CH AC
Manufacturer: Schneider
Product No.: 140DAO84010
Product Type: Discrete Output Module
Product Origin: FR
Payment:T/T, Western Union
Weight: 485g
Shipping port: Xiamen
Warranty: 12 months
Del
- Rask levering
- 24/7 kundestøtte
- Kvalitetssikring
Beskrivelse
Product Overview
The 140DAO84010 is a high-performance discrete output module within the Modicon Quantum automation series by Schneider Electric. Designed to serve as a reliable interface between the PLC and external AC loads, this module provides 16 robust channels for switching industrial actuators, motor starters, and solenoid valves. By utilizing isolated outputs, it ensures electrical separation between channels and the backplane, significantly reducing the risk of system-wide damage from localized electrical faults. Its standard module format allows for seamless integration into existing Quantum racks, making it a staple for large-scale industrial control systems.
Technical Configuration
The 140DAO84010 is configured as a 16-group architecture, where each of the 16 channels is fully isolated, providing 1 group per channel. This specific hardware layout allows for independent control and enhanced protection against electrical noise. The module operates across a broad voltage spectrum from 20 to 132V AC and requires one output word for addressing. For diagnostic clarity, the faceplate includes a green LED for bus communication (Active), a red LED for external fault detection (F), and 16 green status LEDs to provide real-time visual confirmation of each output state. The unit consumes 350 mA from the bus and features a welded hermetic-style durability suitable for varied mounting orientations.
Technical Specifications
| Parameter | Specification |
|---|---|
| Number of Channels | 16 (Isolated) |
| Output Voltage Range | 20 to 132V AC |
| Maximum Load Current | 4 A per point (16 A per module total) |
| Weight | 0.485 kg (1.069 lb) |
| Response Time | < 0.5 ms (State 0 to 1 / 1 to 0) |
| Operating Temp | 0°C to 60°C |
Installation & Maintenance Guide
To ensure optimal performance of the 140DAO84010, the module must be securely seated into a Modicon Quantum rack with the power off. The wiring should be performed using the appropriate terminal block, ensuring that the AC voltage stays within the 20-132V limits. Internal protection is provided by an RC filter; however, an associated fuse rating of 5 A is recommended for external circuit protection. Given its power dissipation of 1.85W plus the load current factor, adequate rack ventilation is required to maintain the operating temperature below 60°C. Regular inspection of the status LEDs is recommended to verify bus health and point-level output status.
Engineering Advantages
The 140DAO84010 excels in high-speed applications due to its sub-0.5 ms response time, facilitating near-instantaneous switching of critical loads. Its absolute maximum output rating of 156V for 10 seconds and 200V for a single cycle allows the module to withstand significant voltage transients without failure. Furthermore, with a high DV/dt rating of 400V/ms, the module is highly resistant to rapid voltage changes, ensuring stable operation in electrically noisy environments. The 16-group isolation is a key engineering benefit, as it prevents a single channel failure from propagating to other points or the main PLC controller.
Technical FAQs
Q1: Does this module support DC outputs?
A1: No, the 140DAO84010 is specifically designed for AC discrete output applications between 20V and 132V AC.
Q2: What is the maximum current this module can handle simultaneously?
A2: While each individual point can handle up to 4 A continuously, the total sum of all 16 points must not exceed 16 A rms per module to ensure thermal stability.
Q3: How does the module handle fault detection?
A3: The module features a dedicated red "F" LED on the front panel that illuminates when an external fault is detected, allowing for rapid troubleshooting without deep software interrogation.
Ytterligere spesifikasjoner
- Grå
- Svart
- Hvit
Skalar (V/f)
Vektor
AC-drevet
Kjøpsveiledning
- Bekreft nøyaktig modell, delenummer og spesifikasjoner før bestilling.
- Sørg for kompatibilitet med ditt nåværende maskineri eller kontrollsystemer.
- Ta kontakt via sale@etowonauto.com eller +8617859788089 for teknisk assistanse.
- Gå gjennom leveringsalternativer, leveringstider og fraktkrav.
- Følg produsentens instruksjoner og beste praksis under installasjon.
Frakt og retur
Varer på lager sendes vanligvis samme virkedag. For produkter som ikke er på lager for øyeblikket, kan leveringstiden variere basert på tilgjengelighet. Internasjonal frakt er tilgjengelig, og fraktkostnader beregnes ut fra destinasjon, vekt og valgt transportør.
Returer godtas innen 30 dager etter mottak, forutsatt at varene er ubrukte og i original stand. Returfraktkostnader dekkes av kunden. Vennligst kontakt oss før du returnerer en vare for å få returautorisasjon.
For mer informasjon, vennligst se vår Frakt- og returpolicy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Rask levering
Originale deler til industriell automasjon tilgjengelig for rask levering over hele verden.
-
Enkel retur
30 dagers returrett med 12 måneders garanti for pålitelig etterkjøpsbeskyttelse.
-
24/7 støtte
Responsiv profesjonell støtte for å hjelpe med å opprettholde stabile og effektive operasjoner.
-
Ekte og original
100 % autentisk, hentet direkte fra pålitelige produsenter av industriell automasjon.
Teknisk og kjøpsguide
-
Hvordan reduserte Emerson Edge Control skyavhengigheten med 60 %?
Emerson Edge Control Terminal behandler OT-data på stedet, reduserer forsinkelsen til under 20 ms og filtrerer ut 60 ...
-
Lavkostnads brownfield-automatisering: Er null nedetid mulig?
Denne artikkelen viser hvordan brownfield-anlegg moderniserer eldre PLC- og DCS-systemer ved hjelp av protokoll-gatew...
-
Hvorfor hindrer multi-protokoll kaos oppgraderinger av automatisering?
Denne artikkelen forklarer hvordan kryssprotokoll dataforbindelse løser barrierer mellom ulike enheter i smart fabrik...
-
Kan Bently Nevada spektrumanalyse forutsi feil på roterende utstyr?
Tradisjonelle PLC- og DCS-systemer klarer ikke å oppdage gradvise vibrasjonsavvik, noe som forårsaker 78 % av feil på...
-
Hvordan løser ABB Drive Control forskyvning i samlebåndets rytme?
Denne artikkelen forklarer hvordan ABBs fjerde generasjons Direct Torque Control (DTC)-teknologi muliggjør presis tak...
-
Er ditt industrielle kontrollutstyr i fare for plutselig svikt?
Tradisjonelt tidsbasert vedlikehold overser mikroslitasje i PLC-, DCS- og TSI-enheter, noe som forårsaker 35 % av upl...
