Forvandle hjemmet ditt med de nyeste multi-elektroniske løsningene, fra intelligent belysning til stemmestyrte enheter – alle designet for å gjøre livet enklere, tryggere og mer tilkoblet. Optimaliser driften med Bently Nevada 3500 overvåkingssystem, som tilbyr sanntids vibrasjons- og maskintilstandsovervåking for å forhindre feil og maksimere oppetid.
SKU:T8461
ICS Triplex T8461 Digital Output TMR Module 40 Channel
Manufacturer: ICS Triplex
Product No.: T8461
Product Type: Digital Output Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 1285g
Shipping port: Xiamen
Warranty: 12 months
Del
- Rask levering
- 24/7 kundestøtte
- Kvalitetssikring
Beskrivelse
Product Overview
The ICS Triplex T8461 is a TMR digital output module with 40 channels, designed for high‑integrity actuation in safety‑critical systems. It delivers 0.75 A per channel across 5 isolated power groups (8 outputs each). The fully triplicated architecture ensures fail‑safe operation, making it ideal for emergency shutdown (ESD), fire & gas, and burner management applications requiring SIL 3 compliance.
Core Advantages
Triple Modular Redundancy
Fully triplicated with 2‑out‑of‑3 voting. Any single fault is automatically masked, guaranteeing continuous, safe output actuation without spurious trips.
Flexible Field Voltage Range
Accepts field voltages from 18 to 60 Vdc, accommodating diverse actuator and solenoid requirements. The 5 independent power groups allow segregated loads for enhanced diagnostics.
High Capacitive Load Capability
Release 3.5 supports up to 3500 µF at 0.75 A, making it suitable for driving large solenoids and valves with high inrush currents.
Specifications
| Parameter | Value |
|---|---|
| System Supply Voltage | 20–32 Vdc |
| System Supply Power | 22 W |
| Field Supply Power (at 24V, 0.75A/ch) | 18 W |
| Output Channels | 40 (5 groups × 8) |
| Operational Field Voltage | 18–60 Vdc |
| Output Current (continuous) | 0.75 A/ch, 6 A/group |
| Min. On‑State Load Current | 25 mA |
| Output On‑State Resistance | 0.6 Ω |
| Off‑State Leakage (equiv. resistance) | 33 kΩ |
| Max Capacitive Load (Release 3.5) | 3500 µF at 0.75 A |
| Turn‑on/off Delay | 0.5 ms |
| Self‑Test Interval | 2 minutes |
| Event Resolution / Accuracy | 1 ms / ±0.5 ms |
| Operating Temperature | -5 °C to +60 °C |
| Humidity | 5–95% RH non‑condensing |
| Certifications | ATEX, IECEx, HazLoc, Ordinary Location |
| Dimensions (H×W×D) | 266 × 31 × 303 mm |
| Weight | 1.285 kg |
Installation Tips
Power Group Segregation
Distribute loads across the 5 independent power groups (8 outputs each) to isolate faults and simplify troubleshooting. Each group has its own field supply return.
Output Wiring
Use shielded cables for field wiring, especially in high‑EMI environments. Keep cable lengths under 30 m to minimise voltage drop and crosstalk.
Capacitive Loads
For loads >55 µF, ensure the module is Release 3.5 or later. It supports up to 3500 µF at 0.75 A, ideal for large solenoids with high inrush.
Hazardous Area
For intrinsic safety, use external barriers as specified. Follow ATEX/IECEx installation rules: certified glands, proper segregation, and observe temperature class.
Why Choose T8461?
Delivers 40 high‑current outputs in a compact 31 mm wide package. The TMR architecture eliminates single points of failure, while the 0.5 ms turn‑on/off delay ensures fast response for critical trips. Withstands harsh industrial environments and integrates seamlessly with ICS Triplex Trusted systems. The high capacitive load capability (3500 µF) reduces the need for external interposing relays, saving panel space and cost.
FAQs
Q1: What is the difference between Release 3.5 and earlier versions?
A1: Release 3.5 increases capacitive load support from 55 µF to 3500 µF at 0.75 A. Recommended for large solenoids or long cable runs.
Q2: Can I use the T8461 with a 48 Vdc field supply?
A2: Yes. The operational field voltage range is 18–60 Vdc, fully compatible with 48 Vdc systems. Ensure total group current stays under 6 A.
Q3: What does the 33 kΩ off‑state leakage mean?
A3: This is the effective leakage resistance when output is off. At 48 Vdc, leakage is below 1.5 mA, preventing false actuation of sensitive loads.
Ytterligere spesifikasjoner
Skalar (V/f)
Vektor
AC-drevet
Kjøpsveiledning
- Bekreft nøyaktig modell, delenummer og spesifikasjoner før bestilling.
- Sørg for kompatibilitet med ditt nåværende maskineri eller kontrollsystemer.
- Ta kontakt via sale@etowonauto.com eller +8617859788089 for teknisk assistanse.
- Gå gjennom leveringsalternativer, leveringstider og fraktkrav.
- Følg produsentens instruksjoner og beste praksis under installasjon.
Frakt og retur
Varer på lager sendes vanligvis samme virkedag. For produkter som ikke er på lager for øyeblikket, kan leveringstiden variere basert på tilgjengelighet. Internasjonal frakt er tilgjengelig, og fraktkostnader beregnes ut fra destinasjon, vekt og valgt transportør.
Returer godtas innen 30 dager etter mottak, forutsatt at varene er ubrukte og i original stand. Returfraktkostnader dekkes av kunden. Vennligst kontakt oss før du returnerer en vare for å få returautorisasjon.
For mer informasjon, vennligst se vår Frakt- og returpolicy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Rask levering
Originale deler til industriell automasjon tilgjengelig for rask levering over hele verden.
-
Enkel retur
30 dagers returrett med 12 måneders garanti for pålitelig etterkjøpsbeskyttelse.
-
24/7 støtte
Responsiv profesjonell støtte for å hjelpe med å opprettholde stabile og effektive operasjoner.
-
Ekte og original
100 % autentisk, hentet direkte fra pålitelige produsenter av industriell automasjon.
Teknisk og kjøpsguide
-
Can Emerson DeltaV DCS Cards Optimize Chemical Safety Loops?
This technical article examines how Emerson DeltaV DCS card upgrades address legacy control limitations in chemical p...
-
Is Partial CNC Board Replacement Better Than a Full System Upgrade?
This technical article examines the dominance of GE Fanuc CNC hardware in heavy-duty automation, supported by field d...
-
Can Genuine PLC Modules Cut DCS Downtime 60%?
This article examines how genuine Allen-Bradley PLC module replacement strategies directly reduce unplanned DCS downt...
-
Is Your GE Fanuc PLC Talking to ABB DCS?
This article reveals how cross-system data silos between GE Fanuc PLC and ABB DCS cause 8–15% production losses in pr...
-
Can Integrated PLC-DCS-TSI Fix Data Silos?
Most industrial digital twins remain static visualization tools because discrete control, process automation, and con...
-
How to Cut Power Plant Outages with ABB and GE Fanuc Retrofits?
This technical article outlines a data-driven approach to modernizing power plant control systems using a hybrid ABB ...