Honeywell FC-TSDI-1624C Safety Manager Input FTA Board

Kun 8 enheter igjen
  • Manufacturer: Honeywell

  • Product No.: FC-TSDI-1624C

  • Product Type: Input Module

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 200g

  • Shipping port: Xiamen

  • Warranty: 12 months

30 dagers returrett · 12 måneders garanti
  • Rask levering
  • 24/7 kundestøtte
  • Kvalitetssikring

Beskrivelse

Product Overview

The FC-TSDI-1624C is a Honeywell Field Termination Assembly (FTA) providing safe, current-limited interfacing for 16 digital inputs. It protects core safety systems in Class I, Division 2 hazardous locations and supports redundant SDI-1624 modules via SICC-0001/Lx cables.

Core Features

  • 16 Channels: Configured as 2 isolated groups of 8 channels.
  • Fault Isolation: Each group is protected by a 250 mA fuse in the common + line.
  • Redundancy Support: Interfaces directly with a redundant pair of SDI-1624 modules.
  • Industrial Mounting: Fits standard TS32 and TS35 × 7.5 DIN rails.

Technical Specifications

Parameter Data
Model Numbers FC-TSDI-1624C / FS-TSDI-1624C
Input Voltage 24 V DC (-15% to +30%)
Input Current ≤ 15 mA at 24 V DC
Igniting Current < 100 mA per channel at 24 V DC +30%
Fuse Specifications 250 mA, 400 V AC/DC (SOC SHV12), Max 175 mA output
Dimensions / Rail Length 170 × 70 × 60 mm / 171 mm rail length
Wire Size / Torque Max 2.5 mm² (AWG 14) / 0.5 Nm (0.37 ft.-lb)
Approvals CE, TUV, UL, CSA, FM

Installation & Field Circuit Data

  • Strip Length: Wire strip length must be exactly 7 mm (0.28 in).
  • Hydrogen Loops (Group A & B): Max 250 Ω resistance, 8 mH inductance, 0.3 µF capacitance.
  • Non-Hydrogen Loops (Group C & D): Min 15 kΩ resistance, 22 mH inductance, 7 µF capacitance.

Technical FAQs

Q1: What does the "C" suffix mean?
A1: Conformal Coating. It shields the internal circuits from humidity and harsh chemical contaminants.

Q2: Why is the continuous output capped at 175 mA for a 250 mA fuse?
A2: It provides a strict safety margin to prevent thermal fatigue and false trips during continuous load.

Q3: Does it support non-redundant installations?
A3: Yes. It works with a single SDI-1624 safety card, keeping the second port open for future upgrades.

🏷️ Tags: Input Module
  • Oransje

Skalar (V/f)

Vektor

AC-drevet

  • Bekreft nøyaktig modell, delenummer og spesifikasjoner før bestilling.
  • Sørg for kompatibilitet med ditt nåværende maskineri eller kontrollsystemer.
  • Ta kontakt via sale@etowonauto.com eller +8617859788089 for teknisk assistanse.
  • Gå gjennom leveringsalternativer, leveringstider og fraktkrav.
  • Følg produsentens instruksjoner og beste praksis under installasjon.

Varer på lager sendes vanligvis samme virkedag. For produkter som ikke er på lager for øyeblikket, kan leveringstiden variere basert på tilgjengelighet. Internasjonal frakt er tilgjengelig, og fraktkostnader beregnes ut fra destinasjon, vekt og valgt transportør.

Returer godtas innen 30 dager etter mottak, forutsatt at varene er ubrukte og i original stand. Returfraktkostnader dekkes av kunden. Vennligst kontakt oss før du returnerer en vare for å få returautorisasjon.

For mer informasjon, vennligst se vår Frakt- og returpolicy.

Vis alle detaljer

SIKRE PÅLITELIG MASKINYTELSE

Forvandle hjemmet ditt med de nyeste multi-elektroniske løsningene, fra intelligent belysning til stemmestyrte enheter – alle designet for å gjøre livet enklere, tryggere og mer tilkoblet. Optimaliser driften med Bently Nevada 3500 overvåkingssystem, som tilbyr sanntids vibrasjons- og maskintilstandsovervåking for å forhindre feil og maksimere oppetid.