Forvandle hjemmet ditt med de nyeste multi-elektroniske løsningene, fra intelligent belysning til stemmestyrte enheter – alle designet for å gjøre livet enklere, tryggere og mer tilkoblet. Optimaliser driften med Bently Nevada 3500 overvåkingssystem, som tilbyr sanntids vibrasjons- og maskintilstandsovervåking for å forhindre feil og maksimere oppetid.
SKU:IS200EPCTG1A
GE IS200EPCTG1A Simplex Exciter PT CT Terminal Module
Manufacturer: General Electric
Product No.: IS200EPCTG1A
Product Type: Terminal Board
Product Origin: USA
Payment:T/T, Western Union
Weight: 450g
Shipping port: Xiamen
Warranty: 12 months
Del
- Rask levering
- 24/7 kundestøtte
- Kvalitetssikring
Beskrivelse
Product Overview
The General Electric IS200EPCTG1A (functional acronym EPCT) is an Exciter PT/CT Input/Output Terminal Board developed for the GE EX2100 Series Excitation Control System. Designed for process-critical power generation environments, this module receives, conditions, scales, and isolates feedback signals from potential transformers (PTs) and current transformers (CTs) directly monitoring two three-phase generator lines.
Operating on a 28 V DC power supply, the IS200EPCTG1A features integrated isolation transformers (T1 through T6) that convert high-level generator feedback signals into low-voltage signals routed via J305, J308, and J315 connectors to the main controller boards (such as EMIO in M1, M2, or C controllers). Weighing 0.45 kg (0.99 lbs) with compact dimensions of 23.8 cm x 8.6 cm, the board operates across an extended industrial temperature range of -30°C to +65°C.
Core Technical Advantages
- Comprehensive Signal Isolation: Six internal isolation transformers (T1–T6) scale and isolate 115 V rms PT inputs and 1 A/5 A CT current signals for safe system feedback.
- Simplex & Triple Redundant Support: Fully scalable for Simplex systems or redundant control architectures using up to three EPCT boards in parallel.
- Flexible Analog Input Configuration: Features jumper JP1 selection to accept either 0–10 V DC or 4–20 mA field analog instrumentation signals.
- Enhanced Terminal Safety: Features non-removable TB2/TB3 terminal blocks to prevent hazardous CT open-circuit conditions during operational service.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Brand / Manufacturer | General Electric (GE) |
| Part / Catalog Number | IS200EPCTG1A |
| Functional Acronym | EPCT (Exciter PT/CT Terminal Board) |
| System Compatibility | GE EX2100 Excitation Control System |
| PT Input Rating | 115 V rms @ 50/60 Hz (Two 3-phase generator PT inputs) |
| PT Step-Down Voltage Output | 1.533 V rms (from 115 V rms 3-wire open delta input) |
| CT Input Rating | 1 A or 5 A nominal inputs from two generators |
| PT/CT Input Burden | Less than 1 VA |
| Auxiliary Analog Input | 1 Channel: 0 to 10 V DC or 4 to 20 mA (Jumper JP1 selectable) |
| Power Supply Voltage | 28 V DC |
| Terminal Blocks & Wiring | 3 Blocks (TB1 removable; TB2/TB3 fixed); supports up to #10 AWG |
| Board Dimensions | 23.8 cm High x 8.6 cm Wide (9.37 in x 3.38 in) |
| Net Board Weight | 0.45 kg (0.99 lbs) |
| Operating Temperature | -30°C to +65°C (-22°F to +149°F) |
Installation & Gap Calibration Guide
- Field Wiring Connection: Wire CT and PT secondary signals to terminal block TB1 using up to #10 AWG cable (maximum run length 1,000 feet / 300 meters).
- Jumper Configuration: Set jumper JP1 to configure the auxiliary analog input for either 0–10 V DC voltage or 4–20 mA current mode prior to powering up.
- CT Safety Notice: Ensure terminal blocks TB2 and TB3 remain permanently attached to prevent dangerous open-circuit voltage spikes across live CT secondaries.
Technical FAQs
Q1: What is the main function of the GE IS200EPCTG1A terminal board?
A1: It conditions, isolates, and scales generator PT and CT feedback signals for EX2100 exciters. (94 chars)
Q2: Why are terminal blocks TB2 and TB3 non-removable on the IS200EPCTG1A?
A2: They are fixed to protect personnel and equipment from open-circuit CT high-voltage hazards. (95 chars)
Q3: How are secondary signals routed to EX2100 system controllers?
A3: Isolated secondary signals are cabled via J305, J308, and J315 connectors to the EMIO board. (93 chars)
Ytterligere spesifikasjoner
- Grønn
Skalar (V/f)
Vektor
AC-drevet
Kjøpsveiledning
- Bekreft nøyaktig modell, delenummer og spesifikasjoner før bestilling.
- Sørg for kompatibilitet med ditt nåværende maskineri eller kontrollsystemer.
- Ta kontakt via sale@etowonauto.com eller +8617859788089 for teknisk assistanse.
- Gå gjennom leveringsalternativer, leveringstider og fraktkrav.
- Følg produsentens instruksjoner og beste praksis under installasjon.
Frakt og retur
Varer på lager sendes vanligvis samme virkedag. For produkter som ikke er på lager for øyeblikket, kan leveringstiden variere basert på tilgjengelighet. Internasjonal frakt er tilgjengelig, og fraktkostnader beregnes ut fra destinasjon, vekt og valgt transportør.
Returer godtas innen 30 dager etter mottak, forutsatt at varene er ubrukte og i original stand. Returfraktkostnader dekkes av kunden. Vennligst kontakt oss før du returnerer en vare for å få returautorisasjon.
For mer informasjon, vennligst se vår Frakt- og returpolicy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Rask levering
Originale deler til industriell automasjon tilgjengelig for rask levering over hele verden.
-
Enkel retur
30 dagers returrett med 12 måneders garanti for pålitelig etterkjøpsbeskyttelse.
-
24/7 støtte
Responsiv profesjonell støtte for å hjelpe med å opprettholde stabile og effektive operasjoner.
-
Ekte og original
100 % autentisk, hentet direkte fra pålitelige produsenter av industriell automasjon.
Teknisk og kjøpsguide
-
Can Eddy-Current Probes Prevent LNG Compressor Shutdowns?
This technical article examines how Bently Nevada eddy-current proximity probes provide high-precision vibration...
-
Can SIL 3 PLCs Really Slash $1M in Annual Offshore Maintenance?
This technical article examines how Allen‑Bradley GuardPLC SIL 3 safety controllers reduce unplanned offshore downtim...
-
Can Emerson DeltaV DCS Cards Optimize Chemical Safety Loops?
This technical article examines how Emerson DeltaV DCS card upgrades address legacy control limitations in chemical p...
-
Is Partial CNC Board Replacement Better Than a Full System Upgrade?
This technical article examines the dominance of GE Fanuc CNC hardware in heavy-duty automation, supported by field d...
-
Can Genuine PLC Modules Cut DCS Downtime 60%?
This article examines how genuine Allen-Bradley PLC module replacement strategies directly reduce unplanned DCS downt...
-
Is Your GE Fanuc PLC Talking to ABB DCS?
This article reveals how cross-system data silos between GE Fanuc PLC and ABB DCS cause 8–15% production losses in pr...