Forvandle hjemmet ditt med de nyeste multi-elektroniske løsningene, fra intelligent belysning til stemmestyrte enheter – alle designet for å gjøre livet enklere, tryggere og mer tilkoblet. Optimaliser driften med Bently Nevada 3500 overvåkingssystem, som tilbyr sanntids vibrasjons- og maskintilstandsovervåking for å forhindre feil og maksimere oppetid.
SKU:3500/33-01-01
Bently Nevada 3500/33-01-01 16-Channel Relay Module
Manufacturer: Bently Nevada
Product No.: 3500/33-01-01
Product Type: Relay Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 700g
Shipping port: Xiamen
Warranty: 12 months
Del
- Rask levering
- 24/7 kundestøtte
- Kvalitetssikring
Beskrivelse
Bently Nevada 3500/33-01-01 16-Channel Relay Module
Bently Nevada 3500/33-01-01 3500/33 16-Channel Relay Output Module. Provides 16 independent SPDT relay outputs for machinery protection systems. Epoxy-sealed relays with arc suppressors ensure reliable operation in demanding industrial environments. cNRTLus certified for Class I Division 2 hazardous areas.
Key Features
16 SPDT relay outputs. Epoxy-sealed environmental sealing. 250 Vrms arc suppressor standard. Four groups of four channels with switch-selectable Normally De-energized (ND) or Normally Energized (NE) operation. Front panel OK, TX/RX, and CH Alarm LEDs. 5.8W typical power consumption. Main module 0.7 kg, I/O module 0.4 kg.
Technical Specifications
| Manufacturer | Bently Nevada |
| Part Number | 3500/33-01-01 |
| Product Type | 3500/33 16-Channel Relay Module |
| Output Module (A) | 01 = 16-Channel Relay Output |
| Approval Option (B) | 01 = cNRTLus (Class I Division 2) |
| Power Consumption | 5.8 W typical |
| Relay Type | Single-pole Double-throw (SPDT) |
| Environmental Sealing | Epoxy-sealed |
| Arc Suppressor | 250 Vrms (standard) |
| Relay Contact Life | 10,000 cycles |
| Relay Operation | 4 groups of 4, switch-selectable ND/NE |
| Main Module Dimensions | 241 x 24.4 x 242 mm (9.50 x 0.96 x 9.52 in) |
| Main Module Weight | 0.7 kg (1.6 lb) |
| I/O Module Dimensions | 241 x 24.4 x 99.1 mm (9.50 x 0.96 x 3.90 in) |
| I/O Module Weight | 0.4 kg (1.0 lb) |
| Rack Space (Main) | 1 full-height front slot |
| Rack Space (I/O) | 1 full-height rear slot |
| Origin | Made in U.S.A. |
Contact Ratings
Standard Relays
| Min Switched Current | 100 mA @ 5 Vdc |
| Max Switched Current | 5 A |
| Max Switched Voltage (DC) | 125 Vdc |
| Max Switched Voltage (AC) | 250 Vac |
| Max Switched Power (DC) | 70W @ 24Vdc, 10W @ 48Vdc, 9W @ 60Vdc |
| Max Switched Power (AC) | 1200 VA |
Failsafe / Hazardous Area Systems
| Min Switched Current | 100 mA @ 5 Vdc |
| Max Switched Current | 5 A |
| Max Switched Voltage | 30 Vdc |
Low Current Applications
| Min Switched Current | 1 mA @ 1 Vdc |
| Max Switched Current | 100 mA @ 48 Vdc |
Ordering Code Breakdown
3500/33-01-01
3500/33 – 16-Channel Relay Module.
A:01 – 16-Channel Relay Output Module.
B:01 – cNRTLus (Class I Division 2) hazardous area approval.
Installation Notes
Install main module in full-height front slot. Install I/O module in corresponding rear slot. Configure relay groups for ND or NE operation via switches. Observe contact rating limits for standard, failsafe, or low current applications. Ensure proper grounding per Bently Nevada guidelines.
Engineering Advantages
16 independent relay outputs provide flexible alarm and control signaling. Epoxy-sealed relays withstand harsh industrial environments. Arc suppressors extend contact life and reduce EMI. cNRTLus certification enables installation in Class I Division 2 hazardous areas. Switch-selectable ND/NE per group simplifies integration with existing control schemes.
FAQs
Q1: How many relay outputs does this module provide?
A1: 16 independent SPDT relay outputs.
Q2: What are the contact ratings for standard applications?
A2: 5A max, 125Vdc or 250Vac, 70W @ 24Vdc.
Q3: What is the relay operation configuration?
A3: Four groups of four channels, switch-selectable for Normally De-energized or Normally Energized operation.
Ytterligere spesifikasjoner
Skalar (V/f)
Vektor
AC-drevet
Kjøpsveiledning
- Bekreft nøyaktig modell, delenummer og spesifikasjoner før bestilling.
- Sørg for kompatibilitet med ditt nåværende maskineri eller kontrollsystemer.
- Ta kontakt via sale@etowonauto.com eller +8617859788089 for teknisk assistanse.
- Gå gjennom leveringsalternativer, leveringstider og fraktkrav.
- Følg produsentens instruksjoner og beste praksis under installasjon.
Frakt og retur
Varer på lager sendes vanligvis samme virkedag. For produkter som ikke er på lager for øyeblikket, kan leveringstiden variere basert på tilgjengelighet. Internasjonal frakt er tilgjengelig, og fraktkostnader beregnes ut fra destinasjon, vekt og valgt transportør.
Returer godtas innen 30 dager etter mottak, forutsatt at varene er ubrukte og i original stand. Returfraktkostnader dekkes av kunden. Vennligst kontakt oss før du returnerer en vare for å få returautorisasjon.
For mer informasjon, vennligst se vår Frakt- og returpolicy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Rask levering
Originale deler til industriell automasjon tilgjengelig for rask levering over hele verden.
-
Enkel retur
30 dagers returrett med 12 måneders garanti for pålitelig etterkjøpsbeskyttelse.
-
24/7 støtte
Responsiv profesjonell støtte for å hjelpe med å opprettholde stabile og effektive operasjoner.
-
Ekte og original
100 % autentisk, hentet direkte fra pålitelige produsenter av industriell automasjon.
Teknisk og kjøpsguide
-
Choosing the Right Gas Detector for Chemical Safety?
This article examines the operational and financial impact of unreliable gas-sensing hardware in chemical process pla...
-
Is Mixed-Plant Data Fragmentation Costing You More?
Hybrid manufacturing facilities often lose nearly one-third of production data across disjointed PLC and DCS systems,...
-
Can Transient Monitoring Prevent Rotating Machinery Failures?
This technical article examines the critical role of transient data capture in rotating machinery protection, highlig...
-
Can Smart Gas Monitoring Cut False Alarms in Oil Facilities?
This article examines gas detection challenges in extreme oil and gas environments where legacy sensors show high dri...
-
Fixed Gas Detector or Transmitter – Which Protects Your Plant Better?
This technical article examines the critical operational differences between fixed gas detectors and gas detection tr...
-
What are real costs of fragmented brownfield control systems?
This article presents a production-focused data interconnection architecture that resolves multi-vendor control syste...