Forvandle hjemmet ditt med de nyeste multi-elektroniske løsningene, fra intelligent belysning til stemmestyrte enheter – alle designet for å gjøre livet enklere, tryggere og mer tilkoblet. Optimaliser driften med Bently Nevada 3500 overvåkingssystem, som tilbyr sanntids vibrasjons- og maskintilstandsovervåking for å forhindre feil og maksimere oppetid.
SKU:6ES7455-1VS00-0AE0
6ES7455-1VS00-0AE0 Siemens | FM 455 S Step and Pulse
Manufacturer: Siemens
Product No.: 6ES7455-1VS00-0AE0
Product Type: Control Module
Product Origin: DE
Payment:T/T, Western Union
Weight: 1400g
Shipping port: Xiamen
Warranty: 12 months
Del
- Rask levering
- 24/7 kundestøtte
- Kvalitetssikring
Beskrivelse
Product Overview
The Siemens 6ES7455-1VS00-0AE0 is an FM 455 S control module for SIMATIC S7-400 systems, providing 16 step and pulse control channels. It combines 16 analog inputs, 16 digital inputs, and 32 digital outputs in a single module. Weighing approximately 1,400 g, this controller supports thermocouples, Pt100 resistance thermometers, and standard signals for comprehensive process control with pulse output capability.
Technical Configuration
This module operates from 24 V DC load voltage with a permissible range of 20.4 to 28.8 V. It draws a maximum of 400 mA (typical 330 mA) from load voltage without load. The 16 analog inputs accept thermocouples or 2-wire connections, while 8 channels support Pt100 or 4-wire connections. The 32 digital outputs feature electronic short-circuit protection and inductive shutdown voltage limitation to L+ (-1.5 V). Potential separation between channels and backplane bus uses optocouplers, tested at 500 V DC isolation.
Technical Specifications
| Parameter | Value |
|---|---|
| Manufacturer | Siemens |
| Part Number | 6ES7455-1VS00-0AE0 |
| Product Type | FM 455 S Control Module |
| Series | SIMATIC S7-400 |
| Control Channels | 16 step and pulse |
| Load Voltage | 24 V DC (20.4-28.8 V) |
| Current from L+ (No Load) | Max 400 mA, typ. 330 mA |
| Power Loss | Typ. 10.7 W, max 16.2 W |
| Digital Inputs | 16, 24 V DC (IEC 61131 type 2) |
| DI Signal "0" / "1" | -3 to +5 V / 13 to 30 V (7 mA typical) |
| Digital Outputs | 32, electronic short-circuit protection |
| Output Current (Rated) | 0.1 A (5-150 mA range, 0-60 °C) |
| Load Resistance Range | 240 Ω to 4 kΩ |
| Lamp Load | Max 5 W |
| Switching Frequency | Max 100 Hz resistive/lamps, 0.5 Hz inductive |
| Analog Inputs | 16 (8 with Pt100/4-wire) |
| Voltage Input Ranges | 0 to +10 V, -1.75 to +11.75 V, -80 to +80 mV |
| Current Input Ranges | 0-20 mA, 0-23.5 mA, -3.5 to +23.5 mA, 4-20 mA |
| Thermocouple Types | B, J, K, R, S |
| RTD Type | Pt100 |
| Resolution | 12 or 14 bit, parameterizable |
| Closed-Loop Controllers | 16 |
| Isolation Tested | 500 V DC |
| Dimensions (W x H x D) | 50 x 290 x 210 mm |
| Weight | Approx. 1,400 g |
| Front Connector | 2 x 48-pin required |
Installation Guide
Install the FM 455 S module in a compatible S7-400 rack slot and secure both 48-pin front connectors. Connect 24 V DC load voltage within the 20.4-28.8 V range. Use shielded cable for analog signals with maximum 200 m length (50 m for 80 mV and thermocouple inputs). Verify digital output loads fall within the 240 Ω to 4 kΩ resistance range. Internal or external Pt100 temperature compensation is parameterizable for thermocouple measurements.
Engineering Advantages
This module integrates 16 closed-loop controllers with 16 AI, 16 DI, and 32 DO in a single unit, combining step/pulse control with analog measurement. The 32 digital outputs provide twice the output density of the FM 455 C, reducing module count in high-channel applications. Electronic short-circuit protection and inductive shutdown voltage limitation safeguard connected loads. Parameterizable 12-bit or 14-bit resolution suits both standard and precision measurement tasks. Optocoupler isolation between channels and backplane bus protects the system from field transients.
Technical FAQs
Q1: How many digital outputs does the 6ES7455-1VS00-0AE0 provide?
A1: This FM 455 S module provides 32 digital outputs with electronic short-circuit protection, plus 16 analog inputs, 16 digital inputs, and 16 closed-loop controllers.
Q2: What is the digital output load resistance range?
A2: Digital outputs operate with load resistance from 240 Ω to 4 kΩ, with rated output current of 0.1 A (5-150 mA range at 0-60 °C).
Q3: What temperature sensor types does this module accept?
A3: It accepts thermocouple types B, J, K, R, and S, plus Pt100 resistance thermometers with parameterizable internal or external compensation.
Ytterligere spesifikasjoner
Skalar (V/f)
Vektor
AC-drevet
Kjøpsveiledning
- Bekreft nøyaktig modell, delenummer og spesifikasjoner før bestilling.
- Sørg for kompatibilitet med ditt nåværende maskineri eller kontrollsystemer.
- Ta kontakt via sale@etowonauto.com eller +8617859788089 for teknisk assistanse.
- Gå gjennom leveringsalternativer, leveringstider og fraktkrav.
- Følg produsentens instruksjoner og beste praksis under installasjon.
Frakt og retur
Varer på lager sendes vanligvis samme virkedag. For produkter som ikke er på lager for øyeblikket, kan leveringstiden variere basert på tilgjengelighet. Internasjonal frakt er tilgjengelig, og fraktkostnader beregnes ut fra destinasjon, vekt og valgt transportør.
Returer godtas innen 30 dager etter mottak, forutsatt at varene er ubrukte og i original stand. Returfraktkostnader dekkes av kunden. Vennligst kontakt oss før du returnerer en vare for å få returautorisasjon.
For mer informasjon, vennligst se vår Frakt- og returpolicy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Rask levering
Originale deler til industriell automasjon tilgjengelig for rask levering over hele verden.
-
Enkel retur
30 dagers returrett med 12 måneders garanti for pålitelig etterkjøpsbeskyttelse.
-
24/7 støtte
Responsiv profesjonell støtte for å hjelpe med å opprettholde stabile og effektive operasjoner.
-
Ekte og original
100 % autentisk, hentet direkte fra pålitelige produsenter av industriell automasjon.
Teknisk og kjøpsguide
-
How Do You Diagnose Degraded MTL Surge Protection Devices?
This article presents field-proven diagnostic checks, aging benchmarks, and installation rules for MTL surge pro...
-
How Can You Stop Nuisance Trips on Bently Nevada TSI Systems?
Nuisance trips on Bently Nevada TSI racks cost power and oil & gas plants $18,000 to $45,000 per event and occur ...
-
When Should You Replace a Yokogawa Analog IO Card?
This article breaks down Yokogawa analog AI/AO card calibration tolerances, drift aging benchmarks, and formal replac...
-
What Performance Gains Does S7-1500 Offer Over Legacy S7 PLCs?
Legacy Siemens S7-300 and S7-400 PLCs face spare-part shortages, rising failure rates and limited network capability,...
-
What Logic Changes Cut SIS False Trips by 94%?
This article examines practical logic modification and parameter tuning methods for ABB 800xA HI SIL3 safety ins...
-
Why Do FTE Redundancy Failovers Lock Up in DCS?
Honeywell FTE delivers sub-500 ms failover for Experion PKS, yet field records show 38% of outages stem from installa...