Forvandle hjemmet ditt med de nyeste multi-elektroniske løsningene, fra intelligent belysning til stemmestyrte enheter – alle designet for å gjøre livet enklere, tryggere og mer tilkoblet. Optimaliser driften med Bently Nevada 3500 overvåkingssystem, som tilbyr sanntids vibrasjons- og maskintilstandsovervåking for å forhindre feil og maksimere oppetid.
SKU:330101-00-60-05-02-05
330101-00-60-05-02-05 Bently Nevada 8mm Probe 3/8-24 UNF
Manufacturer: Bently Nevada
Product No.: 330101-00-60-05-02-05
Product Type: 8 mm Probe
Product Origin: USA
Payment:T/T, Western Union
Weight: 320g
Shipping port: Xiamen
Warranty: 12 months
Del
- Rask levering
- 24/7 kundestøtte
- Kvalitetssikring
Beskrivelse
Bently Nevada 330101-00-60-05-02-05 3300 XL 8mm Probe
Bently Nevada 330101-00-60-05-02-05 is a 3300 XL 8mm proximity probe with 3/8-24 UNF thread without armor. Features 6.0 inch overall case length and 0.5 meter total length. Includes ClickLoc connector with standard cable and multiple agency approvals. Weight: 0.32 kg (0.71 lbs).
Technical Specifications
| Parameter | Specification |
| Manufacturer | Bently Nevada |
| Model | 330101-00-60-05-02-05 |
| Probe Type | 3300 XL 8mm Probe, 3/8-24 UNF thread, without armor |
| Unthreaded Length | 0.0 inch |
| Overall Case Length | 6.0 inches |
| Total Length | 0.5 meter (1.6 feet) |
| Connector Type | Miniature coaxial ClickLoc, standard cable |
| Thread Size | 3/8-24 UNF |
| Agency Approval | CSA, ATEX, IECEx (Option 05) |
| Probe DC Resistance (0.5m) | 7.45 ± 0.50 ohms |
| Linear Range | 2 mm (80 mils) from 0.25 to 2.3 mm |
| Recommended Gap for Radial Vibration | -9 Vdc (1.27 mm / 50 mils) |
| Incremental Scale Factor (0.5m System) | 7.87 V/mm (200 mV/mil) ±5% |
| Deviation from Best Fit Line | Less than ±0.025 mm (±1 mil) |
| Probe Tip Material | Polyphenylene sulfide (PPS) |
| Probe Case Material | AISI 303 or 304 stainless steel |
| Operating Temperature (Standard) | -52°C to +177°C (-62°F to +350°F) |
| Extension Cable Capacitance | 69.9 pF/m (21.3 pF/ft) typical |
| Maximum Field Wiring Length | 305 meters (1,000 feet) |
| Humidity Tolerance | 93% RH per IEC 68-2-3, less than 3% ASF change |
| Weight | 0.32 kg (0.71 lbs) |
| Origin | Made in U.S.A. |
Configuration Breakdown
| Code | Description |
| 00 | 0.0 inch unthreaded length |
| 60 | 6.0 inch overall case length |
| 05 | 0.5 meter total length |
| 02 | ClickLoc connector, standard cable |
| 05 | CSA, ATEX, IECEx approvals |
Key Features
- 6.0 inch overall case length for deep mounting applications
- 0.5 meter total length for flexible installation
- Patented TipLoc molding for robust bond between probe tip and body
- Patented CableLoc design provides 330 N (75 lbf) pull strength
- 8mm PPS probe tip with thicker encapsulation for rugged durability
- CSA, ATEX, and IECEx approvals for hazardous area operation
- 93% humidity tolerance with less than 3% ASF drift
- Made in U.S.A. with Certificate of Origin available
Installation Guidelines (Field Engineer Notes)
Gap Setting: Recommended radial gap is -9 Vdc at 1.27 mm (50 mils). Linear range begins at 0.25 mm (10 mils) from target.
Field Wiring: Use 3-conductor shielded triad cable (16-24 AWG) with tinned wiring. Maximum length is 305 meters (1,000 feet) between Proximitor Sensor and monitor.
Probe Case Torque: Recommended torque for 3/8-24 UNF is 5.1 N·m (45 in·lb). Maximum 7.3 N·m (65 in·lb).
Temperature Warning: Exposing the probe to temperatures below -34°C (-30°F) may cause premature failure of the pressure seal.
Connector Torque: Finger tight maximum. Do not exceed 0.56 N·m (5 in·lb).
FAQs
Q1. What is the advantage of the 6.0 inch case length?
A1. The 6.0 inch overall case length allows deep mounting in applications where standard length probes cannot reach the target, ideal for large machinery and thick housing walls.
Q2. What approvals does Option 05 include?
A2. Option 05 provides multiple agency approvals including CSA, ATEX, and IECEx for hazardous area operation worldwide.
Q3. What is the pull strength of the CableLoc design?
A3. The patented CableLoc design provides 330 N (75 lbf) pull strength to securely attach the probe cable and probe tip.
Ytterligere spesifikasjoner
Skalar (V/f)
Vektor
AC-drevet
Kjøpsveiledning
- Bekreft nøyaktig modell, delenummer og spesifikasjoner før bestilling.
- Sørg for kompatibilitet med ditt nåværende maskineri eller kontrollsystemer.
- Ta kontakt via sale@etowonauto.com eller +8617859788089 for teknisk assistanse.
- Gå gjennom leveringsalternativer, leveringstider og fraktkrav.
- Følg produsentens instruksjoner og beste praksis under installasjon.
Frakt og retur
Varer på lager sendes vanligvis samme virkedag. For produkter som ikke er på lager for øyeblikket, kan leveringstiden variere basert på tilgjengelighet. Internasjonal frakt er tilgjengelig, og fraktkostnader beregnes ut fra destinasjon, vekt og valgt transportør.
Returer godtas innen 30 dager etter mottak, forutsatt at varene er ubrukte og i original stand. Returfraktkostnader dekkes av kunden. Vennligst kontakt oss før du returnerer en vare for å få returautorisasjon.
For mer informasjon, vennligst se vår Frakt- og returpolicy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Rask levering
Originale deler til industriell automasjon tilgjengelig for rask levering over hele verden.
-
Enkel retur
30 dagers returrett med 12 måneders garanti for pålitelig etterkjøpsbeskyttelse.
-
24/7 støtte
Responsiv profesjonell støtte for å hjelpe med å opprettholde stabile og effektive operasjoner.
-
Ekte og original
100 % autentisk, hentet direkte fra pålitelige produsenter av industriell automasjon.
Teknisk og kjøpsguide
-
Can Eddy-Current Probes Prevent LNG Compressor Shutdowns?
This technical article examines how Bently Nevada eddy-current proximity probes provide high-precision vibration...
-
Can SIL 3 PLCs Really Slash $1M in Annual Offshore Maintenance?
This technical article examines how Allen‑Bradley GuardPLC SIL 3 safety controllers reduce unplanned offshore downtim...
-
Can Emerson DeltaV DCS Cards Optimize Chemical Safety Loops?
This technical article examines how Emerson DeltaV DCS card upgrades address legacy control limitations in chemical p...
-
Is Partial CNC Board Replacement Better Than a Full System Upgrade?
This technical article examines the dominance of GE Fanuc CNC hardware in heavy-duty automation, supported by field d...
-
Can Genuine PLC Modules Cut DCS Downtime 60%?
This article examines how genuine Allen-Bradley PLC module replacement strategies directly reduce unplanned DCS downt...
-
Is Your GE Fanuc PLC Talking to ABB DCS?
This article reveals how cross-system data silos between GE Fanuc PLC and ABB DCS cause 8–15% production losses in pr...