Forvandle hjemmet ditt med de nyeste multi-elektroniske løsningene, fra intelligent belysning til stemmestyrte enheter – alle designet for å gjøre livet enklere, tryggere og mer tilkoblet. Optimaliser driften med Bently Nevada 3500 overvåkingssystem, som tilbyr sanntids vibrasjons- og maskintilstandsovervåking for å forhindre feil og maksimere oppetid.
SKU:1794-OB16
1794-OB16 Allen-Bradley Flex I/O 16 Sourcing Output
Manufacturer: Allen-Bradley
Product No.: 1794-OB16
Product Type: Digital Output Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 78g
Shipping port: Xiamen
Warranty: 12 months
Del
- Rask levering
- 24/7 kundestøtte
- Kvalitetssikring
Beskrivelse
Allen-Bradley 1794-OB16 Flex I/O DC Sourcing Output Module
Allen-Bradley 1794-OB16 | Flex I/O discrete DC output module with 16 sourcing output channels. Operates at 24V DC nominal voltage with 8.0 A total output current rating. Compatible with 1794-TB2, 1794-TB3, 1794-TB3S, 1794-TB3K, and 1794-TB3SK terminal bases. Weight: approximately 78 g (2.75 oz).
Key Features
16 sourcing output channels. 24V DC nominal on-state voltage (10-31.2V DC range). 8.0 A total output current rating (500 mA per channel). Maximum on-state voltage drop 0.5V DC. Maximum off-state leakage 0.5 mA. 50V continuous isolation voltage. Surge current 2 A for 50 ms, repeatable every 2 seconds. Output signal delay 0.5 ms (OFF-to-ON) and 1 ms (ON-to-OFF). 80 mA Flexbus current at 5V DC. 16 yellow status indicators. Keyswitch position 2. Supports up to 8 modules per Flex I/O rack.
Technical Specifications
| Manufacturer | Rockwell Automation |
| Brand | Allen-Bradley |
| Part Number | 1794-OB16 |
| Product Type | Flex I/O Digital DC Output Module |
| Outputs | 16 (Sourcing) |
| On-State Voltage (Nominal) | 24V DC |
| On-State Voltage (Min) | 10V DC |
| On-State Voltage (Max) | 31.2V DC |
| Output Current Rating | 8.0 A (total) |
| On-State Current (Min) | 1 mA per channel |
| On-State Current (Max) | 500 mA per channel |
| On-State Voltage Drop | 0.5V DC max |
| Off-State Leakage Current | 0.5 mA max |
| Isolation Voltage | 50V continuous |
| Surge Current | 2 A for 50 ms, repeatable every 2 s |
| Signal Delay (OFF-to-ON) | 0.5 ms |
| Signal Delay (ON-to-OFF) | 1 ms |
| Flexbus Current | 80 mA @ 5V DC |
| Power Dissipation | 5.3 W @ 31.2V DC max |
| Thermal Dissipation | 18.1 BTU/hr @ 31.2V DC max |
| Indicators | 16 Yellow status indicators |
| Keyswitch Position | 2 |
| Enclosure | Open-type |
| Mounting | DIN Rail |
| Dimensions (H x W x D) | 94 x 94 x 69 mm (3.7 x 3.7 x 2.7 in) |
| Weight | Approx. 78 g (2.75 oz) |
| Operating Temperature | 0°C to +55°C (32°F to 131°F) |
| Storage Temperature | -40°C to +85°C (-40°F to 185°F) |
| Vibration | 5g @ 10-500 Hz |
| Operating Shock | 30 g |
| Certifications | c-UL-us, CSA, CE, Ex, TÜV, KC, EAC, RCM |
| UPC | 10612598137852 |
Installation Notes
Install on compatible terminal base with keyswitch set to Position 2. Compatible terminal bases: 1794-TB2, 1794-TB3, 1794-TB3S, 1794-TB3K, 1794-TB3SK. This module has no internal fusing; install external fusing as required by the system (recommended: SAN-O MQ4-800 mA). Supports up to 8 modules per Flex I/O rack. Can also be used as local I/O adapter for FlexLogix Controller or 1794-FLA extender. Wire size determined by installed terminal base.
Engineering Advantages
16 sourcing outputs in a single Flex I/O module maximize channel density. High 8.0 A module rating handles demanding DC loads directly. Fast 0.5 ms OFF-to-ON response supports time-critical control applications. 16 yellow status indicators simplify field diagnostics. Supports distributed I/O architecture via any 1794 Flex I/O adapter. Wide certification portfolio (c-UL-us, CSA, CE, Ex, TÜV, KC, EAC, RCM) enables global deployment.
FAQs
Q1: How many outputs does this module provide?
A1: 16 sourcing DC outputs, 500 mA per channel.
Q2: What is the output voltage range?
A2: 10-31.2V DC, with a nominal rating of 24V DC.
Q3: Does this module include internal fusing?
A3: No internal fusing. External fusing is recommended (SAN-O MQ4-800 mA) as required by the system.
Ytterligere spesifikasjoner
- Grå
Skalar (V/f)
Vektor
AC-drevet
Kjøpsveiledning
- Bekreft nøyaktig modell, delenummer og spesifikasjoner før bestilling.
- Sørg for kompatibilitet med ditt nåværende maskineri eller kontrollsystemer.
- Ta kontakt via sale@etowonauto.com eller +8617859788089 for teknisk assistanse.
- Gå gjennom leveringsalternativer, leveringstider og fraktkrav.
- Følg produsentens instruksjoner og beste praksis under installasjon.
Frakt og retur
Varer på lager sendes vanligvis samme virkedag. For produkter som ikke er på lager for øyeblikket, kan leveringstiden variere basert på tilgjengelighet. Internasjonal frakt er tilgjengelig, og fraktkostnader beregnes ut fra destinasjon, vekt og valgt transportør.
Returer godtas innen 30 dager etter mottak, forutsatt at varene er ubrukte og i original stand. Returfraktkostnader dekkes av kunden. Vennligst kontakt oss før du returnerer en vare for å få returautorisasjon.
For mer informasjon, vennligst se vår Frakt- og returpolicy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Rask levering
Originale deler til industriell automasjon tilgjengelig for rask levering over hele verden.
-
Enkel retur
30 dagers returrett med 12 måneders garanti for pålitelig etterkjøpsbeskyttelse.
-
24/7 støtte
Responsiv profesjonell støtte for å hjelpe med å opprettholde stabile og effektive operasjoner.
-
Ekte og original
100 % autentisk, hentet direkte fra pålitelige produsenter av industriell automasjon.
Teknisk og kjøpsguide
-
How Do You Diagnose Degraded MTL Surge Protection Devices?
This article presents field-proven diagnostic checks, aging benchmarks, and installation rules for MTL surge pro...
-
How Can You Stop Nuisance Trips on Bently Nevada TSI Systems?
Nuisance trips on Bently Nevada TSI racks cost power and oil & gas plants $18,000 to $45,000 per event and occur ...
-
When Should You Replace a Yokogawa Analog IO Card?
This article breaks down Yokogawa analog AI/AO card calibration tolerances, drift aging benchmarks, and formal replac...
-
What Performance Gains Does S7-1500 Offer Over Legacy S7 PLCs?
Legacy Siemens S7-300 and S7-400 PLCs face spare-part shortages, rising failure rates and limited network capability,...
-
What Logic Changes Cut SIS False Trips by 94%?
This article examines practical logic modification and parameter tuning methods for ABB 800xA HI SIL3 safety ins...
-
Why Do FTE Redundancy Failovers Lock Up in DCS?
Honeywell FTE delivers sub-500 ms failover for Experion PKS, yet field records show 38% of outages stem from installa...