Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:48931006-AV
YPP109A 48931006-AV ABB Advant OCS Operator Keyboard
Manufacturer: ABB
Product No.: 48931006-AV
Product Type: Operator Keyboard
Product Origin: Sweden
Payment:T/T, Western Union
Weight: 1000g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Product Overview
The ABB YPP109A 48931006-AV is an industrial operator keyboard assembly for ABB Advant OCS and MOD 300 operator stations. Designed for 24/7 control room use with 44 tactile keys, integrated cursor control, and durable membrane construction. Weight: 1.0 kg.
Core Advantages
Purpose-Built for DCS Operations
Non-standard layout with dedicated function keys for alarm acknowledge, screen recall, and device start/stop. Optimized for fast, error-free operator input.
Integrated Cursor Control
"AV" suffix indicates built-in joystick or trackball for precise on-screen navigation. Faster than keyboard-only navigation in process control.
Rugged Industrial Construction
IP65-rated membrane keys resist dust, oil, and frequent use. Key life rated >1,000,000 presses.
Specifications
| Parameter | Value |
|---|---|
| Part Number | YPP109A 48931006-AV |
| Manufacturer | ABB |
| Type | Operator Keyboard Assembly |
| Compatible Systems | Advant OCS, MOD 300, AS Series |
| Number of Keys | 44 |
| Cursor Control | Integrated joystick or trackball |
| Connectivity | RS-232, USB |
| Operating Voltage | 24V DC |
| IP Rating | IP65 |
| Operating Temperature | -20°C to +60°C |
| Storage Temperature | -20°C to +70°C |
| Key Life | >1,000,000 presses |
| Dimensions (W×H×D) | 12.7 × 32.7 × 3.3 cm |
| Weight | 1.0 kg |
Installation Tips
System Compatibility
Verify your operator station model (Advant OCS, MOD 300, or AS Series) before ordering. Connector type may vary between stations.
Connection
Connect via RS-232 or USB depending on station interface. Keyboard is typically powered by the host station.
Mounting
Designed for control room desk or console mounting. Ensure cable routing does not interfere with operator access.
Why Choose YPP109A 48931006-AV?
Direct replacement for ABB Advant OCS operator keyboards. 44 dedicated function keys for fast process control. Integrated cursor control saves desk space. IP65 membrane construction for industrial reliability. Compatible with legacy DCS installations.
FAQs
Q1: What does the "AV" suffix indicate?
A1: The AV suffix indicates the keyboard includes an integrated analog joystick or trackball for cursor control.
Q2: Which ABB systems is this keyboard compatible with?
A2: It is designed for ABB Advant OCS, MOD 300, and possibly AS Series operator stations. Verify your specific station model before ordering.
Q3: Is this a standard PC keyboard?
A3: No. It is a specialized industrial keyboard with non-standard function keys for process control applications, not a standard 101-key PC layout.
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
How to Diagnose GE PACSystem PLC Faults Fast?
GE PACSystem PLC faults disrupt factory automation and process control. This article explains field-proven diagnosis ...
-
How Does ABB Robot Integration Boost Automotive Throughput?
ABB robot integration helps automotive plants cut material handling stoppages and raise throughput. Success depends o...
-
How Does Bently Nevada Vibration Analysis Catch Faults?
Bently Nevada vibration analysis helps industrial automation teams detect rotating machinery faults early by combinin...
-
How Do GE Edge Gateways Enable Zero-Downtime Data Collection?
GE industrial edge gateways let plants collect real-time PLC and DCS data without stopping production. They read lega...
-
How Does Honeywell SCADA Unify Multi-Site Manufacturing?
Honeywell SCADA enables manufacturers to unify monitoring across three to eight distributed plants while preserv...
-
How Do Eddy Current Probes Protect Rotating Machinery?
Bently Nevada eddy current proximity sensors deliver precise shaft displacement data for turbine and compressor prote...
