Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:ATV71HU55N4
Variable Speed Drive 7.5 hp Schneider Electric ATV71HU55N4
Manufacturer: Schneider
Product No.: ATV71HU55N4
Product Type: Variable Speed Drive
Product Origin: FR
Payment:T/T, Western Union
Weight: 5500g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Schneider Electric ATV71HU55N4 Altivar 71 Variable Speed Drive
The Schneider Electric ATV71HU55N4, also cataloged as the ATV71HU55N4 Variable Speed Drive, operates as a three-phase drive delivering 5.5 kW (7.5 hp) motor power from a 380-480 VAC input with integrated EMC filter and heat sink within Altivar 71 platforms.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | ATV71HU55N4 |
| Brand | Schneider Electric |
| Product Type | Variable Speed Drive |
| Product Line | Altivar 71 |
| Weight | 5.5 kg net (12.1 lb) |
| Dimensions (W x H x D) | 175 mm x 295 mm x 187 mm |
| Phase | 3-phase |
| Input Voltage | 380-480 VAC, -15% to +10%; limits 323-528 V |
| Input Frequency | 50/60 Hz, -5% to +5%; limits 47.5-63 Hz |
| Motor Power | 5.5 kW / 7.5 hp |
| Line Current | 17 A at 480 V; 20.3 A at 380 V |
| Nominal Output Current | 11 A at 460 V; 14.3 A at 380 V (4 kHz) |
| Maximum Transient Current | 23.6 A for 2 s; 21.5 A for 60 s |
| Output Frequency | 0.1 to 599 Hz |
| Nominal Switching Frequency | 4 kHz; adjustable 1-16 kHz |
| Apparent Power | 13.4 kVA at 380 V |
| Prospective Line Isc | 22 kA |
| Operating Temp | -10 deg C to 50 deg C without derating |
| Storage Temp | -25 deg C to 70 deg C |
| Relative Humidity | 5-95% without condensation |
| IP Degree of Protection | IP20 |
| EMC Filter | Integrated |
| Assembly Style | With heat sink |
| Max Motor Cable Length | 50 m shielded; 100 m unshielded |
| Communication Protocol | Modbus (2-wire RS 485), CANopen |
| Certifications | CE, UL, CSA, C-tick, GOST, NOM 117 |
| UPC | 785901785606 |
Frequently Asked Questions
Q: What is the net weight of the ATV71HU55N4?
A: 5.5 kg (12.1 lb) net.
Q: What motor cable length is permitted with this drive?
A: 50 m with shielded cable and 100 m with unshielded cable.
Q: What is the nominal switching frequency and adjustment range?
A: 4 kHz nominal, adjustable from 1 to 16 kHz, with derating applied from 4 to 16 kHz.
Field Installation Guidelines
Mount the drive vertically within +/-10 degrees on a panel with the heat sink airflow path unobstructed. Verify three-phase input is within 323-528 V and 47.5-63 Hz before energizing. Confirm prospective short-circuit current at the installation point does not exceed 22 kA. Route motor cables within 50 m shielded or 100 m unshielded limits. Separate power and control wiring; control terminals accept 2.5 mm2 (AWG 14) and power terminals accept 6 mm2 (AWG 8). Tighten power terminals to 3 N.m and control terminals to 0.6 N.m. Ground the drive per site standards and verify dielectric isolation before commissioning. Derate output current by 1% per 100 m above 1000 m altitude. Verify the integrated EMC filter configuration matches the installation environment category before connecting the motor.
Ƙarin ƙayyadaddun bayanai
- Launin toka
- mai aiki da wutar DC
- mai amfani da wutar AC
- Ƙarami
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
How Do MTL Intrinsic Safety Barriers Protect Petrochemical DCS Loops?
This article explains how industrial automation teams size MTL intrinsic safety barriers for petrochemical DCS a...
-
How Does Bently 3500 TSI Detect Proximity Probe Faults?
This article explains Bently 3500 TSI proximity probe troubleshooting, technical parameters and calibrated insta...
-
How to Diagnose Yokogawa CENTUM VP FCS Redundancy Faults?
This article explains how industrial automation teams can diagnose and debug Yokogawa CENTUM VP FCS controller redund...
-
How Does Siemens S7-1500 PLC Handle PROFINET Real-Time Jitter?
This article examines measurable PROFINET fault modes on Siemens S7-1500 PLC controllers and provides field-prov...
-
Why Do ABB AC800M Redundancy Mismatch Faults Keep Returning?
ABB AC800M redundancy mismatch faults account for 42.7 percent of controller alarms in 800xA systems. Most stem ...
-
How Does Honeywell C300 Improve on C200 DCS Controllers?
Honeywell C300 controllers deliver major gains over C200 in memory, scan speed, redundancy switching, and reliability...