Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:V18345-1010120001
TZIDC Positioner Single Acting | V18345-1010120001 ABB
Manufacturer: ABB
Product No.: V18345-1010120001
Product Type: Valve Positioner Module
Product Origin: Sweden
Payment:T/T, Western Union
Weight: 1700g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Product Overview
The V18345-1010120001 is a TZIDC electro-pneumatic positioner from ABB, designed for precise valve control on linear and rotary actuators. Features 4–20 mA two-wire input, HART communication, and single-acting fail-safe output. Aluminum housing with IP65/NEMA 4X protection. Weight: 1.7 kg.
Technical Configuration
Control Characteristics
Signal 4–20 mA corresponds to actuator position 0–100%, freely selectable for split-range operation (min range 20% / 3.2 mA). Characteristic curve: linear, equal percentage 1:25/1:50 or 25:1/50:1, freely configurable with 20 reference points. Travel limit adjustable to 20% minimum.
Technical Specifications
| Parameter | Specification |
|---|---|
| Part Number | V18345-1010120001 |
| Manufacturer | ABB |
| Type | TZIDC Electro-Pneumatic Positioner |
| Input Signal | 4–20 mA (two-wire), split-range selectable |
| Communication | HART, LKS local connector |
| Output / Safe Position | Single acting, fail safe |
| Supply Pressure | 1.4–6 bar (20–90 psi) |
| Air Consumption | <0.03 kg/h / 0.015 scfm |
| Housing Material | Aluminum, varnished, RAL 9005 |
| Protection Class | IP65 / NEMA 4X |
| Pneumatic Connections | G 1/4 or 1/4-18 NPT |
| Electrical Connections | 2 tap holes 1/2-14 NPT or M20 x 1.5 |
| Screw Terminals | Max 1.0 mm² (options) / 2.5 mm² (analog signal) |
| Digital Input | 0–5 V DC (logical 0), 11–30 V DC (logical 1) |
| Digital Output | 5–11 V DC (NAMUR DIN 19234) |
| Ambient Temperature | -40°C to +85°C (operation/storage/transport) |
| Humidity (Operational) | 95% annual average, condensation permissible |
| Humidity (Transport/Storage) | 75% annual average, non-condensing |
| Characteristic Curve | Linear, equal percentage, freely configurable (20 points) |
| Travel Limit | 0–100%, min 20% |
| Shut-off Function | Separately settable per end position |
| Travel Time Prolongation | Settable per direction |
| Weight | 1.7 kg |
Installation & Maintenance
Mounting
Mount to linear actuators per DIN/IEC 534/NAMUR or rotary actuators per VDI/VDE 3845. Integral mounting ready. Do not expose screw terminals to strain.
Air Supply
Use instrument air free of oil, water, and dust. Supply pressure 1.4–6 bar (20–90 psi). Do not exceed actuator max operating pressure. Air consumption <0.03 kg/h independent of supply pressure.
Electrical Connection
Connect 4–20 mA two-wire signal. Cable entry: 2 tap holes 1/2-14 NPT or M20 x 1.5 (one with cable gland, one with pipe plug). HART communication via signal line.
Engineering Advantages
Precise Valve Control
Freely configurable characteristic curves with 20 reference points. Split-range operation down to 20% (3.2 mA). Separate shut-off function and travel time prolongation per direction for precise process control.
Robust Environmental Protection
IP65/NEMA 4X aluminum housing with electrostatic epoxy varnish resists corrosion. Operates from -40°C to +85°C with 95% humidity (condensation permissible). Suitable for demanding industrial environments.
Flexible Configuration
Single-acting fail-safe output ensures safe valve position on power loss. HART communication enables remote diagnostics. Travel limit adjustable within 0–100% (minimum 20%) for application flexibility.
Technical FAQs
Q1: What is the supply pressure range for this positioner?
A1: 1.4–6 bar (20–90 psi). Do not exceed the maximum operating pressure of the actuator.
Q2: What is the fail-safe behavior on electrical power failure?
A2: The 1 suffix indicates single-acting, fail-safe output. The actuator moves to its safe position on loss of electrical power.
Q3: What ambient temperature range does this positioner support?
A3: -40°C to +85°C for operation, storage, and transport. When using proximity switches SJ2-S1N (NO), the range is -25°C to +85°C.
Ƙarin ƙayyadaddun bayanai
- Azurfa
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
How Can You Tune GE RX3i and RX7i Ethernet for Heavy Industry?
Intermittent Ethernet timeouts on GE RX3i and RX7i controllers are among the hardest faults in heavy process plants, ...
-
Why Does FCS Redundancy Not Protect Your HIS Configuration?
This article examines the operational risks of Yokogawa CENTUM VP HIS lockups and explains why FCS controller re...
-
How Does 1756 Analog I/O Calibration Drift Affect PLC Accuracy?
This article examines calibration drift in Allen-Bradley ControlLogix 1756 analog I/O modules, presenting quanti...
-
Why Do 31% of ABB 800xA S800 IO Hot Swaps Fail in DCS Systems?
ABB 800xA S800 hot swap failures rarely stem from defective hardware. Field data from 142 card replacement jobs shows...
-
How Do You Diagnose Degraded MTL Surge Protection Devices?
This article presents field-proven diagnostic checks, aging benchmarks, and installation rules for MTL surge pro...
-
How Can You Stop Nuisance Trips on Bently Nevada TSI Systems?
Nuisance trips on Bently Nevada TSI racks cost power and oil & gas plants $18,000 to $45,000 per event and occur ...