Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:V18347-2041150001
TZIDC-120 Foundation Fieldbus Positioner ABB | V18347-2041150001
Manufacturer: ABB
Product No.: V18347-2041150001
Product Type: Valve Positioner Module
Product Origin: Sweden
Payment:T/T, Western Union
Weight: 1700g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
ABB V18347-2041150001 TZIDC-120 Electro-Pneumatic Positioner
Product Overview
ABB V18347-2041150001 is a TZIDC-120 intelligent, configurable electro-pneumatic positioner for FOUNDATION Fieldbus communication. Features varnished aluminum case with mechanical position indicator and IP65 (NEMA 4X) protection. Mounts to linear actuators per DIN/IEC 534/NAMUR or rotary actuators per VDI/VDE 3845. ATEX EEx ia IIC T6 intrinsically safe certified. Single acting fail safe action. Cable connection M20x1.5 and air pipe 1/4-18 NPT. Weight 1.7 kg.
Model Number Decoder
| Position | Code | Meaning |
|---|---|---|
| Base | V18347 | TZIDC-120 Positioner for FOUNDATION Fieldbus |
| Case/Mounting | 20 | Aluminum case with mechanical position indicator |
| Input/Communication | 4 | FOUNDATION Fieldbus |
| Explosion Protection | 1 | ATEX EEx ia IIC T6 |
| Output/Safe Position | 1 | Single acting, fail safe |
| Connections | 5 | Cable M20x1.5, Air 1/4-18 NPT |
| Shutdown Function | 0 | Without |
| Mech Feedback Kit | 00 | Without |
| Design | 1 | Standard |
Technical Specifications
| Parameter | Value |
|---|---|
| Brand | ABB |
| Model | V18347-2041150001 |
| Type | TZIDC-120 Electro-Pneumatic Positioner |
| Communication | FOUNDATION Fieldbus |
| Explosion Protection | ATEX EEx ia IIC T6 intrinsically safe |
| Action | Single Acting, Fail Safe |
| Position Indicator | Mechanical, built in |
| Protection Class | IP65, NEMA 4X |
| Housing Material | Aluminum, epoxy resin varnish |
| Electrical Connection | M20x1.5 (2 threads, 1 gland, 1 plug) |
| Pneumatic Connection | G 1/4 or 1/4-18 NPT |
| Screw Terminals | Max 1.0 mm² (options), max 2.5 mm² (analog) |
| Operating Temperature | 40°C to +85°C |
| Temperature with SJ2-S1N | 25°C to +85°C |
| Humidity Operational | 95% annual average, condensation permissible |
| Humidity Storage | 75% annual average, non condensing |
| Weight | 1.7 kg |
Installation
Mount on linear actuators per DIN/IEC 534/NAMUR or rotary actuators per VDI/VDE 3845. Connect FOUNDATION Fieldbus cable at M20x1.5 cable entry. Use 1 thread with cable gland and 1 with pipe plug. Connect air supply at G 1/4 or 1/4-18 NPT. Do not expose terminals to strain. For ATEX intrinsically safe installation, observe EEx ia IIC T6 temperature limits and certified barriers. Verify IP65 seal after installation.
Features
TZIDC-120 intelligent configurable positioner with indicator and operator panel. FOUNDATION Fieldbus digital communication for advanced diagnostics. Built in mechanical position indicator for visual feedback. ATEX EEx ia IIC T6 intrinsically safe certification. Single acting fail safe action for power failure safety. Aluminum case with epoxy resin varnish IP65 NEMA 4X. Operating temperature 40°C to +85°C. Humidity tolerance 95% with condensation permissible. Weight 1.7 kg.
FAQ
Q1: What communication protocol does this positioner use?
A1: FOUNDATION Fieldbus digital communication. Supports advanced diagnostics and remote configuration via the fieldbus network.
Q2: What is the explosion protection rating?
A2: ATEX EEx ia IIC T6 intrinsically safe. Suitable for Zone 1 hazardous area installation with certified barriers.
Q3: What is the action type and temperature range?
A3: Single acting fail safe action. Operating temperature 40°C to +85°C. Humidity 95% annual average with condensation permissible.
Ƙarin ƙayyadaddun bayanai
- Azurfa
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
What Logic Changes Cut SIS False Trips by 94%?
This article examines practical logic modification and parameter tuning methods for ABB 800xA HI SIL3 safety ins...
-
Why Do FTE Redundancy Failovers Lock Up in DCS?
Honeywell FTE delivers sub-500 ms failover for Experion PKS, yet field records show 38% of outages stem from installa...
-
How Does the Bently Nevada 3500/42M Vibration Module Drift?
This technical guide examines the Bently Nevada 3500/42M vibration module within industrial automation architect...
-
What Causes IC694MDL Fault Codes in GE RX3i PLC Systems?
This guide explains GE RX3i IC694MDL discrete I/O fault codes, key electrical parameters, ESD and torque requirements...
-
What CFC Rules Cut PCS7 Batch Abort Rates Fast?
This article presents enforceable CFC programming governance rules for Siemens PCS7 DCS batch plants, covering b...
-
What Makes the 1769-L3ER Ideal for Compact Skid Automation?
This guide explains how the Allen-Bradley 1769 CompactLogix L3ER bridges the gap between micro PLCs and large DC...