Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:TSXDMZ28DT
TSXDMZ28DT Schneider | 16 Input 12 Output Module | 24VDC
Manufacturer: Schneider
Product No.: TSXDMZ28DT
Product Type: I/O Base
Product Origin: FR
Payment:T/T, Western Union
Weight: 425g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Product Overview
The Schneider TSXDMZ28DT is a discrete solid state I/O base designed for Modicon TSX Micro automation platforms. It provides 16 discrete inputs and 12 discrete outputs operating at 24V DC with positive logic. Drawing 132 mA, this module delivers 3.5W power dissipation per module and 0.15W per channel. Weighing 0.425 kg, it suits compact industrial control panels.
Technical Configuration
Inputs require at least 11V for state 1 and less than 5V for state 0, with 7 mA input current and 3.4 Ohm impedance. Inputs accept 2-wire and 3-wire proximity sensors. Outputs maintain 19-30V with 0.625A current limit and 48 Ohm load impedance. Protection features include zener diode overvoltage protection, current limiter and electronic circuit breaker short-circuit protection, and reverse polarity diode.
Technical Specifications
| Parameter | Value |
|---|---|
| Manufacturer | Schneider Electric |
| Product Line | Modicon TSX Micro |
| Part Number | TSXDMZ28DT |
| EAN | 3389110540451 |
| Product Type | Discrete solid state I/O base DC |
| Discrete Inputs | 16 (1 HE-10 connector) |
| Discrete Outputs | 12 (screw terminal block) |
| Operating Voltage | 24 V DC |
| Input Voltage Limits | ≥ 11 V at state 1, < 5 V at state 0 |
| Input Current | 7 mA |
| Input Impedance | 3.4 Ohm |
| Output Voltage Limits | 19-30 V |
| Output Current Limits | 0.625 A |
| Max Leakage Current | 0.5 mA at state 0 |
| Residual Voltage | 0.3 V |
| Load Impedance | 48 Ohm |
| Switching Frequency | < 0.6/LI² Hz |
| Output Response Time | ≤ 0.5 ms |
| Input Response Time | 0.1...7.5 ms |
| Isolation Voltage | 1500 V for 1 second |
| Current Consumption | 132 mA |
| Power Dissipation | 3.5 W by module, 0.15 W by channel, 5 W input |
| Paralleling of Outputs | Yes, 2 maximum |
| Dimensions (H x W x L) | 5.5 x 18.0 x 26.0 cm |
| Net Weight | 0.425 kg (0.937 lbs) |
| Operating Temperature | -20°C to 55°C |
| Standards | IEC 1131-2 Type 1 |
Installation Guide
Mount the module into a compatible TSX Micro PLC rack using the 1 HE-10 connector for inputs and screw terminal blocks for outputs. Verify input voltage reaches at least 11V for state 1 activation. Confirm output loads do not exceed 0.625A and maintain minimum 48 Ohm impedance. Connect 2-wire or 3-wire proximity sensors to the discrete inputs. Ensure proper grounding to preserve the 1500V isolation rating.
Engineering Advantages
This module combines 16 inputs and 12 outputs in a single compact unit, reducing panel space requirements. Solid state outputs deliver fast 0.5 ms response times for precise control. Triple protection (overvoltage, short-circuit, reverse polarity) safeguards connected equipment. Paralleling up to 2 outputs supports higher current load applications. Wide -20°C to 55°C operating range suits diverse industrial conditions.
Technical FAQs
Q1: How many inputs and outputs does the TSXDMZ28DT provide?
A1: This module includes 16 discrete inputs and 12 discrete outputs operating at 24V DC with positive logic.
Q2: What protection features are integrated into the outputs?
A2: Outputs include zener diode overvoltage protection, current limiter and electronic circuit breaker short-circuit protection, and reverse polarity diode.
Q3: What is the output response time?
A3: The TSXDMZ28DT delivers ≤ 0.5 ms output response time for both state transitions.
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
How Do You Tune a 3500/92 Gateway for Stable Modbus TCP Polling?
This article explains why Bently Nevada 3500/92 Modbus TCP gateways fail in industrial control systems and how automa...
-
How Can You Prevent GE PLC Backup Failures?
This article explains why GE PLC backup failures occur in RX3i and VersaMax environments. It presents measured root c...
-
Why Does PCS7 OS Server Redundancy Fail Over?
This guide explains how to diagnose and repair Siemens PCS7 OS server redundancy failover anomalies using quantified ...
-
How Do You Recover a Bricked Allen-Bradley PLC?
This article explains how industrial automation teams classify bricked Allen-Bradley Logix controllers, validate firm...
-
How Can You Prevent Historian Data Loss During Experion PKS Migration?
This article presents a measurable playbook for protecting Honeywell Experion historian data during server and H...
-
How Do MTL Barriers and DCS IO Cards Affect Loop Voltage?
Intrinsic safety circuits protect hazardous process areas, yet loop impedance budgeting often receives far less atten...