Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:TSXAEY1600
TSXAEY1600 Schneider Analog Input Module 16 Channel 12-Bit
Manufacturer: Schneider
Product No.: TSXAEY1600
Product Type: Analog Input Module
Product Origin: FR
Payment:T/T, Western Union
Weight: 340g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Schneider Electric TSXAEY1600 Analog Input Module
Product Overview
The Schneider Electric TSXAEY1600 is a high-level analog input module for the TSX Micro and Modicon Premium PLC platforms. It features 16 analog input channels with 12-bit A/D conversion, supporting current (0-20 mA, 4-20 mA) and voltage (±10 V, 0-10 V, 0-5 V, 1-5 V) input types. The module provides 1000 Vrms isolation between channels and bus/ground. Weight is 0.34 kg (0.75 lbs).
Specifications
| Parameter | Value |
|---|---|
| Brand | Schneider Electric |
| Model | TSXAEY1600 |
| Product Line | TSX Micro / Modicon Premium |
| Product Type | Analog Input Module |
| Input Channels | 16 High-Level Analog Inputs |
| Input Types (Current) | 0-20 mA, 4-20 mA |
| Input Types (Voltage) | ±10 V, 0-10 V, 0-5 V, 1-5 V |
| A/D Conversion | 12 bits |
| Nominal Read Cycle Time | 51 ms |
| Fast Read Cycle Time | 3 ms + 3 ms per channel used |
| Measurement Error (25 °C) | 0.1% of full scale (voltage), 0.16% (current) |
| Measurement Error (0-60 °C) | 0.13% of full scale (voltage), 0.32% (current) |
| Isolation (Channels to Bus) | 1000 Vrms |
| Isolation (Channels to Ground) | 1000 Vrms |
| Input Overvoltage Protection | -15 to 15 V (state 0), -30 to 30 V (state 1) |
| Electrical Connection | 2 x SUB-D 25 connectors |
| Current Consumption | 270 mA @ 5 VDC |
| Module Format | Standard |
| Protection Rating | IP20 |
| Operating Temperature | 0 to 60 °C |
| Storage Temperature | -25 to 70 °C |
| Relative Humidity (Operation) | 10-95% (non-condensing) |
| Weight | 0.34 kg (0.75 lbs) |
| EAN | 3389110726114 |
| Country of Origin | France (FR) |
Certifications
- IEC 1131
- Marine: BV, GL, LR, DNV, RINA, ABS, RMRS
- CE Marked
Key Features
- 16 high-level analog input channels
- Supports current (0-20 mA, 4-20 mA) and voltage (±10 V, 0-10 V, 0-5 V, 1-5 V) inputs
- 12-bit analog-to-digital conversion for precise measurement
- 1000 Vrms isolation between channels and bus/ground
- Fast read cycle time: 3 ms + 3 ms per channel
- Nominal read cycle time: 51 ms
- Measurement error 0.1% of full scale at 25 °C (voltage)
- Input overvoltage protection -30 to 30 V at state 1
- Two SUB-D 25 connectors for electrical connection
- Marine certified (BV, GL, LR, DNV, RINA, ABS, RMRS)
- IP20 protection rating
Installation Notes
Install the module in a TSX Micro or Modicon Premium PLC rack. Connect field wiring using the two SUB-D 25 connectors. Observe input overvoltage limits of -15 to 15 V at state 0 and -30 to 30 V at state 1. Maintain operating temperature between 0 and 60 °C with relative humidity 10-95% (non-condensing). The 1000 Vrms isolation protects both the bus and ground paths. For marine applications, the module holds certifications from all major classification societies.
FAQs
Q1: What input types does the TSXAEY1600 support?
A1: Current inputs (0-20 mA, 4-20 mA) and voltage inputs (±10 V, 0-10 V, 0-5 V, 1-5 V).
Q2: What is the A/D conversion resolution?
A2: 12-bit analog-to-digital conversion.
Q3: What is the isolation rating of this module?
A3: 1000 Vrms between channels and bus, and 1000 Vrms between channels and ground.
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
Why Does PCS7 OS Server Redundancy Fail Over?
This guide explains how to diagnose and repair Siemens PCS7 OS server redundancy failover anomalies using quantified ...
-
How Do You Recover a Bricked Allen-Bradley PLC?
This article explains how industrial automation teams classify bricked Allen-Bradley Logix controllers, validate firm...
-
How Can You Prevent Historian Data Loss During Experion PKS Migration?
This article presents a measurable playbook for protecting Honeywell Experion historian data during server and H...
-
How Do MTL Barriers and DCS IO Cards Affect Loop Voltage?
Intrinsic safety circuits protect hazardous process areas, yet loop impedance budgeting often receives far less atten...
-
How Can You Tune GE RX3i and RX7i Ethernet for Heavy Industry?
Intermittent Ethernet timeouts on GE RX3i and RX7i controllers are among the hardest faults in heavy process plants, ...
-
Why Does FCS Redundancy Not Protect Your HIS Configuration?
This article examines the operational risks of Yokogawa CENTUM VP HIS lockups and explains why FCS controller re...