Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:6ES7463-2AA00-0AA0
Siemens 6ES7463-2AA00-0AA0 S7-400 IM 463-2 Transmitter Module
Manufacturer: Siemens
Product No.: 6ES7463-2AA00-0AA0
Product Type: Interface Module
Product Origin: DE
Payment:T/T, Western Union
Weight: 360g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Siemens 6ES7463-2AA00-0AA0 SIMATIC S7-400 Interface Module Send IM 463-2
Product Overview
Siemens 6ES7463-2AA00-0AA0 is a SIMATIC S7-400 interface module send IM 463-2 for distributed coupling to SIMATIC S5 expansion devices via IM 314. Supports cable lengths up to 600 meters. Features two parallel symmetrical interfaces with RS 485 differential signals. Input current 1320 mA maximum from 5V DC backplane bus. Power loss 6600 mW maximum.
Technical Specifications
| Parameter | Value |
|---|---|
| Brand | Siemens |
| Model | 6ES7463-2AA00-0AA0 |
| Series | SIMATIC S7-400 |
| Type | Interface Module Send IM 463-2 |
| Application | Distributed coupling to SIMATIC S5 via IM 314 |
| Interfaces | 2 parallel symmetrical (RS 485 differential) |
| Max Cable Length | 600 m |
| Transmission Speed | 100 kbit/s to 2 Mbit/s |
| Input Current | 1320 mA max from 5V DC backplane bus |
| Power Loss | 6600 mW max |
| Front Connectors | 2 x 50 pin male |
| Dimensions W x H x D | 25 x 290 x 217 mm |
| Weight | 360 g |
Installation
Install module in SIMATIC S7-400 central rack. Prepare connecting cable using 721 cable with replacement connector housing (two housings included). Insert cable into front connector X1 (top, interface C1) or X2 (bottom, interface C2). Set interface selector switch (C1 ON, C2 ON, both ON, or both OFF). Set cable length selector switch: 100 (1-100m), 250 (100-250m), 450 (250-450m), or 600 (450-600m). Only change switch settings in CPU STOP mode.
Features
Distributed coupling to SIMATIC S5 expansion devices via IM 314 up to 600 meters. Two parallel symmetrical interfaces with RS 485 differential signals. Transmission speed 100 kbit/s to 2 Mbit/s. Interface selector switch for C1, C2, or both. Cable length selector switch for 100/250/450/600 m ranges. EXTF LED for external fault indication. C1 and C2 green LEDs for line status. Requires STEP 7 V2.1 or higher programming package.
FAQ
Q1: What is the maximum cable length for S5 coupling?
A1: 600 meters between the IM 463-2 and the last IM 314. Set cable length selector switch to the appropriate range (100, 250, 450, or 600).
Q2: What do the LED indicators show?
A2: EXTF (red) indicates external fault such as line fault, missing termination connector, or incorrect interface switch setting. C1 (green) and C2 (green) indicate line 1 and line 2 are OK.
Q3: Can the interface and cable length switches be changed during operation?
A3: No. Only change switch settings in CPU STOP mode. Changing settings in RUN mode can cause data loss.
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
How to Diagnose Yokogawa CENTUM VP FCS Redundancy Faults?
This article explains how industrial automation teams can diagnose and debug Yokogawa CENTUM VP FCS controller redund...
-
How Does Siemens S7-1500 PLC Handle PROFINET Real-Time Jitter?
This article examines measurable PROFINET fault modes on Siemens S7-1500 PLC controllers and provides field-prov...
-
Why Do ABB AC800M Redundancy Mismatch Faults Keep Returning?
ABB AC800M redundancy mismatch faults account for 42.7 percent of controller alarms in 800xA systems. Most stem ...
-
How Does Honeywell C300 Improve on C200 DCS Controllers?
Honeywell C300 controllers deliver major gains over C200 in memory, scan speed, redundancy switching, and reliability...
-
How Does the 1756-RM2 Redundancy Module Work?
This article explains how to install, configure and tune the Allen-Bradley 1756-RM2 redundancy module for Contro...
-
How Do You Migrate DeltaV Classic DCS Without Plant Shutdown?
This article explains why Emerson DeltaV Classic systems reach technical limits after 15 to 20 years and how plants c...
