Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:BMXCPS4002S
Schneider BMXCPS4002S X80 Power Module 100-240V AC Safety
Manufacturer: Schneider
Product No.: BMXCPS4002S
Product Type: Power Supply
Product Origin: FR
Payment:T/T, Western Union
Weight: 510g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
BMXCPS4002S Schneider Modicon X80 Redundant Power Supply – 100-240V AC Safety
The Schneider Electric BMXCPS4002S is a redundant power supply module for the Modicon X80 range with safety certification. Accepts 100-240V AC input with 15W at 3.3V DC and 40W at 24V DC secondary output. Net weight is 0.51 kg.
Product Information
| Manufacturer | Schneider Electric |
| Range of Product | Modicon X80 |
| Part Number | BMXCPS4002S |
| Product Type | Power Supply Module (Redundant, Safety) |
| Backplane Compatibility | All Backplanes |
| Primary Voltage | 100-240V AC |
| Primary Voltage Limit | 85-264V |
| Network Frequency | 50/60 Hz (Limits 47-63 Hz) |
| Net Weight | 0.51 kg |
| Country of Origin | Indonesia |
| GTIN | 3606481204950 |
Secondary Power Output
| 3.3V DC Output | 15W (I/O Module Logic) |
| 24V DC Output | 40W (I/O Module Power and Processor) |
| Current at 3.3V DC | 4.5 A |
| Current at 24V DC | 1.67 A |
| Max Power Dissipation | 8.5W |
Input Specifications
| Apparent Power | 0.13 kVA |
| Input Current at 230V | 0.55 A |
| Input Current at 115V | 1.1 A |
| Inrush Current at 115V | 30 A |
| Inrush Current at 230V | 60 A |
| I²t on Activation | 1 A²·s at 115V, 4 A²·s at 230V |
Protection and Isolation
| Primary Protection | Internal Fuse (Not Accessible) |
| Secondary Protection | Overload, Overvoltage, Short-Circuit |
| Insulation Resistance | ≥100 MOhm Primary/Ground and Primary/Secondary |
| Dielectric Strength (Primary/Secondary) | 1500V |
| Dielectric Strength (Sensor Power) | 2300V |
| Dielectric Strength (Primary/Ground) | 1500V |
| Microbreak Immunity | 10 ms |
Environmental Specifications
| Operating Temperature | -25°C to 60°C (-13°F to 140°F) |
| Storage Temperature | -40°C to 85°C (-40°F to 185°F) |
| Relative Humidity | 5% to 95% at 55°C Non-Condensing |
| IP Protection | IP20 |
| Vibration Resistance | 3 gn |
| Shock Resistance | 15 gn |
| Operating Altitude | 0-2000 m (2000-5000 m with Derating) |
Diagnostics and Status
- Redundancy Test via Network
- Temperature Sensing
- Remaining Lifetime Monitoring
- Uptime Duration Tracking
- OK LED (Green) – Presence of Voltages
- Redundancy OK LED (Green)
- Power Supply Status LED (Green)
- RESET Push-Button for Cold Restart
Certifications and Standards
| Product Certifications | CE, UL, CSA, RCM, EAC, Merchant Navy, ATEX Zone 2/22, IECEx Zone 2/22, TÜV |
| Standards | EN/IEC 61131-2, EN/IEC 61010-2-201, UL 61010-2-201, CSA C22.2 No 61010-2-201, IACS E10, EN/IEC 61000-6-5, EN/IEC 61850-3, EN/IEC 60079-0 |
| Directives | 2014/30/EU EMC, 2006/42/EC Machinery, 2014/34/EU ATEX |
Features
- Redundant power supply for Modicon X80
- Safety certified with SIL 3 capability
- 100-240V AC wide input range
- Dual secondary output: 15W at 3.3V DC and 40W at 24V DC
- Advanced network diagnostics
- Conformal coating for harsh environments
- ATEX Zone 2/22 and IECEx Zone 2/22 certified
- High MTBF of 792000 hours
- Compact 0.51 kg design
Applications
- Safety-critical process control
- Redundant power systems
- Industrial automation
- Oil and gas installations
- Power generation control
FAQs
Q1: What is the input and output power rating?
A1: 100-240V AC input with 15W at 3.3V DC and 40W at 24V DC secondary output.
Q2: What diagnostics are available via network?
A2: Redundancy test, temperature sensing, remaining lifetime, and uptime duration.
Q3: What is the weight and MTBF reliability?
A3: 0.51 kg with MTBF reliability of 792000 hours.
Ƙarin ƙayyadaddun bayanai
- mai aiki da wutar DC
- Ƙarami
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
How Can You Avoid Hidden Faults in Logix5000 PLC Migration?
Allen-Bradley Logix5000 migration involves far more than a firmware flash. Version jumps from V20 to V30 can add 0.4 ...
-
How Do Thermal Stress and Aging Affect Ovation I/O Module Life?
This article explains how thermal stress, vibration and capacitor aging degrade Emerson Ovation I/O modules in power ...
-
How Does ABB AC500-eCo Cut Machining Automation Costs?
This article explains how the ABB AC500-eCo compact PLC fits discrete machining automation, covering CPU memory ...
-
What Makes GE VersaMax Micro PLC Ideal for Factory Retrofits?
This article reviews the GE VersaMax Micro PLC as a practical retrofit solution for compact factory automation, cover...
-
Is DeltaV S-Series DCS Right for Fine Chemical Skids?
This article reviews the Emerson DeltaV S-Series DCS as a compact control solution for modular fine chemical skids, c...
-
How Does GE RX3i PACSystem Redundancy Improve Oil & Gas Skid Control?
This article explores GE RX3i PACSystem redundant control architecture for oil and gas skid automation. It cover...
