Tsallake zuwa abun ciki
Kayan aikin sarrafa kansu, isarwa a ko’ina cikin duniya
Tsallaka zuwa bayanin kaya
1 na 3

SKU:ATV71HU55N4Z

Schneider ATV71HU55N4Z Altivar 71 VSD 5.5kW

A kan haja (21 guda), a shirye don aikawa
  • Manufacturer: Schneider

  • Product No.: ATV71HU55N4Z

  • Product Type: Variable Speed Drive

  • Product Origin: FR

  • Payment:T/T, Western Union

  • Weight: 5500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Dokar Mayar da Kaya na Kwanaki 30 · Garantin Watanni 12
  • Isarwa Cikin Gaggawa
  • Tallafi na awa 24 a rana, kwana 7 a mako
  • Tabbacin Inganci

Bayani

Schneider Electric ATV71HU55N4Z Altivar 71 Variable Speed Drive

Schneider Electric ATV71HU55N4Z | Altivar 71 variable speed drive for complex, high-power machines. Delivers 5.5 kW (7.5 HP) motor power with 14.3 A nominal output current at 380-480V three-phase supply. Integrated EMC filter and heat sink. Supplied without remote graphic terminal. Supports asynchronous and synchronous motors. Weight: 5.5 kg (12.1 lbs).

Technical Specifications

Manufacturer Schneider Electric
Part Number ATV71HU55N4Z
Product Line Altivar 71
Product Type Variable Speed Drive
Motor Power 5.5 kW (7.5 HP), 3-phase 380-480V
Supply Voltage 380-480V (-15%/+10%), 3-phase
Supply Voltage Limits 323-528V
Supply Frequency 50-60 Hz ±5% (47.5-63 Hz)
Line Current (480V) 17 A
Line Current (380V) 20.3 A
Apparent Power 13.4 kVA @ 380V
Nominal Output Current (460V) 11 A @ 4 kHz
Nominal Output Current (380V) 14.3 A @ 4 kHz
Maximum Transient Current 21.5 A for 60 s; 23.6 A for 2 s
Output Frequency 0.1-599 Hz
Nominal Switching Frequency 4 kHz (adjustable 1-16 kHz)
Prospective Line Isc 22 kA
EMC Filter Integrated
Heat Sink Yes
Display Interface Without remote graphic terminal
Control Methods Sensorless Vector, Vector, V/f, Synchronous
Analog Inputs 2 (AI1 ±10V, AI2 0-20mA/0-10V)
Analog Output 1 (AO1 0-20mA/0-10V)
Discrete Inputs 7 (LI1-LI5 programmable 24VDC, LI6 configurable, PWR safety)
Discrete Outputs 2 relay (R1 NO/NC, R2 NO)
Communication Modbus (2-wire RS485), CANopen
Transmission Rates (Modbus) 4800, 9600, 19200, 38.4 kbps
Transmission Rates (CANopen) 20 kbps to 1 Mbps
Speed Accuracy (Closed-Loop) ±0.01% of nominal speed
Torque Accuracy (Closed-Loop) ±5%
Transient Overtorque 170% for 60 s; 220% for 2 s
Braking Torque (with resistor) ≤150%
Insulation Resistance >1 MOhm at 500V DC for 1 minute
Dielectric Strength 3535V DC (earth to power); 5092V DC (control to power)
Protection Class IP20 (upper), IP21, IP41 (upper), IP54 (lower)
Noise Level 55.6 dB (86/188/EEC)
Operating Temperature -10°C to +50°C (without derating)
Storage Temperature -25°C to +70°C
Relative Humidity 5-95% (non-condensing)
Operating Altitude ≤1000 m without derating; 1000-3000 m with 1% derating per 100 m
Vibration Resistance 1 gn (13-200 Hz); 1.5 mm peak-to-peak (3-13 Hz)
Shock Resistance 15 gn, 11 ms (IEC 60068-2-27)
Dimensions (H x W x D) 295 x 175 x 187 mm (11.6 x 6.9 x 7.4 in)
Net Weight 5.5 kg (12.1 lbs)
Standards IEC 61800-3, IEC 61800-5-1, UL Type 1
Certifications CE, UL, CSA, GOST, NOM 117, C-tick

Additional Technical Parameters

Maximum Motor Cable Length (Shielded) 50 m (164.04 ft)
Maximum Motor Cable Length (Unshielded) 100 m (328.08 ft)
Analog Input Sampling Time 2 ms ±0.5 ms
Discrete Input Sampling Time 2 ms ±0.5 ms
STO Response Time ≤100 ms
Relay Output Response Time 7 ms ±0.5 ms
Analog Input Linearity Error ±0.15% of maximum value
Analog Output Linearity Error ±0.2%
Relay Mechanical Life 100,000 cycles
Minimum Switching Current 3 mA at 24V DC

Installation Notes

Mount vertically (±10°) on a wall or in an enclosure. Connect 380-480V three-phase supply per local electrical codes. Observe terminal tightening torques: 0.6 N·m for control terminals, 3 N·m for power terminals. Maximum motor cable length is 50 m shielded or 100 m unshielded. Maintain operating temperature within -10°C to +50°C without derating. For altitudes above 1000 m, apply 1% current derating per 100 m. Ensure proper grounding and use the integrated EMC filter for electromagnetic compliance. The Z suffix indicates the drive ships without a remote graphic terminal; configure via local keypad or connected software.

FAQs

Q1: What is the motor power rating of this drive?
A1: 5.5 kW (7.5 HP) at 380-480V three-phase supply.

Q2: What communication protocols are built in?
A2: Modbus (2-wire RS485) and CANopen.

Q3: What does the Z suffix indicate?
A3: The drive is supplied without a remote graphic display terminal.

🏷️ Tags: Variable Speed Drive
  • mai aiki da wutar DC
  • Ƙarami

Sikeli (V/f)

Vector

mai amfani da wutar AC

  • Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
  • Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
  • Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
  • Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
  • Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.

Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.

Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.

Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

Duba bayanin samfur

TABBTAR DA INGANTACCEN AIKIN NA'URORI

Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.