Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:ATV71HU30N4
Schneider ATV71HU30N4 | 3kW Variable Speed Drive Modbus
Manufacturer: Schneider
Product No.: ATV71HU30N4
Product Type: Variable Speed Drive
Product Origin: FR
Payment:T/T, Western Union
Weight: 4000g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Schneider Electric ATV71HU30N4 Altivar 71 Variable Speed Drive
Product Overview
The Schneider Electric ATV71HU30N4 is a variable speed drive from the Altivar 71 series, designed for complex, high-power machines. It delivers 3 kW (3 HP) motor power for 3-phase 380-480 V asynchronous and synchronous motors, with an output current range of 6.2 to 7.8 A. The drive features an integrated EMC filter, heat sink assembly, and a wide output frequency range of 0.1 to 599 Hz. Weight is 4 kg (8.8 lbs).
Specifications
| Parameter | Value |
|---|---|
| Brand | Schneider Electric |
| Model | ATV71HU30N4 |
| Product Line | Altivar 71 |
| Product Type | Variable Speed Drive |
| Motor Power | 3 kW (3 HP), 3-Phase 380-480 V |
| Input Voltage | 380-480 VAC (-15% to +10%) |
| Supply Voltage Limits | 323-528 V |
| Frequency | 50/60 Hz (±5%), Limits 47.5-63 Hz |
| Line Current (480 V) | 9 A |
| Line Current (380 V) | 10.7 A |
| Nominal Output Current (380 V) | 7.8 A @ 4 kHz |
| Nominal Output Current (460 V) | 6.2 A @ 4 kHz |
| Output Current Range | 6.2-7.8 A |
| Max Transient Current | 11.7 A (60 s) / 12.9 A (2 s) |
| Output Frequency | 0.1-599 Hz |
| Nominal Switching Frequency | 4 kHz |
| Switching Frequency Range | 1-16 kHz (4-16 kHz with derating) |
| Apparent Power | 7 kVA at 380 V |
| Max Motor Cable Length | 50 m Shielded / 100 m Unshielded |
| EMC Filter | Integrated |
| Assembly Style | With Heat Sink |
| Output Voltage | 0-380/480 V (3-Phase) |
| Dimensions (W x H x D) | 155 x 260 x 187 mm |
| Weight | 4 kg (8.8 lbs) |
| UPC | 785901602866 |
Additional Technical Parameters
| Parameter | Value |
|---|---|
| Speed Range (Open-Loop) | 1-100 Asynchronous Motor |
| Speed Range (Closed-Loop) | 1-1000 Asynchronous Motor with Encoder |
| Speed Accuracy (Closed-Loop) | ±0.01% of Nominal Speed |
| Torque Accuracy (Closed-Loop) | ±5% |
| Transient Overtorque | 170% (60 s) / 220% (2 s) |
| Braking Torque (with Resistor) | ≤150% |
| Braking Torque (without Resistor) | 30% |
| Acceleration/Deceleration Ramps | 0.01-9000 s (Linear, S, U, Customized) |
| Analogue Inputs | 2 (AI1 ±10 VDC, AI2 0-20 mA / 0-10 VDC) |
| Analogue Output | 1 (AO1 0-20 mA / 0-10 VDC) |
| Discrete Inputs | 7 (LI1-LI5 24 VDC, LI6 Switchable PTC) |
| Discrete Outputs | 2 Relay (R1 NO/NC, R2 NO) |
| Relay Switching Current | 5 A (250 VAC / 30 VDC Resistive) |
| Communication Protocols | Modbus, CANopen |
| Dielectric Strength (Power/Earth) | 3535 VDC |
| Dielectric Strength (Control/Power) | 5092 VDC |
| Operating Temperature | -10 to +50 °C (Without Derating) |
| Storage Temperature | -25 to +70 °C |
| Protection Rating | IP20 |
| Operating Altitude (No Derating) | ≤1000 m |
FAQs
Q1: What motor power rating does the ATV71HU30N4 provide?
A1: 3 kW (3 HP) for 3-phase 380-480 V asynchronous and synchronous motors.
Q2: What is the output current range of this drive?
A2: 6.2 to 7.8 A, with nominal output current of 7.8 A at 380 V and 6.2 A at 460 V.
Q3: Does this drive include an EMC filter?
A3: Yes. The ATV71HU30N4 features an integrated EMC filter, reducing the need for external filtering components.
Ƙarin ƙayyadaddun bayanai
- mai aiki da wutar DC
- Ƙarami
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
How Do MTL Intrinsic Safety Barriers Protect Petrochemical DCS Loops?
This article explains how industrial automation teams size MTL intrinsic safety barriers for petrochemical DCS a...
-
How Does Bently 3500 TSI Detect Proximity Probe Faults?
This article explains Bently 3500 TSI proximity probe troubleshooting, technical parameters and calibrated insta...
-
How to Diagnose Yokogawa CENTUM VP FCS Redundancy Faults?
This article explains how industrial automation teams can diagnose and debug Yokogawa CENTUM VP FCS controller redund...
-
How Does Siemens S7-1500 PLC Handle PROFINET Real-Time Jitter?
This article examines measurable PROFINET fault modes on Siemens S7-1500 PLC controllers and provides field-prov...
-
Why Do ABB AC800M Redundancy Mismatch Faults Keep Returning?
ABB AC800M redundancy mismatch faults account for 42.7 percent of controller alarms in 800xA systems. Most stem ...
-
How Does Honeywell C300 Improve on C200 DCS Controllers?
Honeywell C300 controllers deliver major gains over C200 in memory, scan speed, redundancy switching, and reliability...
