Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:140NOM21100
Schneider 140NOM21100 DIO Adaptor
Manufacturer: Schneider
Product No.: 140NOM21100
Product Type: Adaptor Module
Product Origin: FR
Payment:T/T, Western Union
Weight: 482g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Schneider Electric Modicon Quantum 140NOM21100 DIO Head-End Adaptor Module
The 140NOM21100 is a DIO (Distributed I/O) head-end adaptor module from the Schneider Electric Modicon Quantum automation platform. This module features two communication ports: one Modbus Plus RS485 twisted pair (single copper) and one Modbus RS232 twisted pair (single copper). It operates at 1 Mbit/s transmission rate with 30 input / 32 output I/O words capacity.
Key Features
- DIO head-end adaptor for Modicon Quantum systems
- Dual communication ports:
- 1 x Modbus Plus RS485 twisted pair (single copper)
- 1 x Modbus RS232 twisted pair (single copper)
- Transmission rate: 1 Mbit/s
- I/O words capacity: 30 input / 32 output words
- Compatible with 140CRA21120 and 140CRA21110 modules
- Built-in diagnostics: processor, checksum, RAM address, RAM checks
- Power dissipation: 4 W
- Bus current requirement: 780 mA
- Multiple certifications: CSA, RMRS, FM Class 1 Division 2, C-tick, GOST
Technical Specifications
- Brand: Schneider Electric
- Series: Modicon Quantum
- Model: 140NOM21100
- Product Type: DIO Head-End Adaptor Module
- Number of Ports: 2
- Port 1: Modbus Plus RS485 twisted pair (single copper)
- Port 2: Modbus RS232 twisted pair (single copper)
- Transmission Rate: 1 Mbit/s
- I/O Words: 30 input / 32 output words
- Power Dissipation: 4 W
- Bus Current Requirement: 780 mA
- Module Format: Standard
- Compatible Modules: 140CRA21120, 140CRA21110
Diagnostic Checks
- Processor check
- Checksum verification
- RAM address check
- RAM integrity check
Certifications
- CSA
- RMRS
- FM Class 1 Division 2
- C-tick
- GOST
- UL 508 compliant
Environmental Specifications
- Operating Temperature: 0 to 60°C (32 to 140°F)
- Storage Temperature: -40 to 85°C (-40 to 185°F)
- Relative Humidity: 95% without condensation
- Operating Altitude: ≤ 5000 m (16404 ft)
- Resistance to Electrostatic Discharge: 4 kV contact, 8 kV air (IEC 801-2)
- Resistance to Electromagnetic Fields: 9.1 V/m (10 V/m) 80-2000 MHz (IEC 801-3)
Package Details
- Package Dimensions:
- Height: 4.5 cm (1.77 in)
- Width: 16.5 cm (6.50 in)
- Length: 31.0 cm (12.20 in)
- Package Weight: 482.0 g (17.002 oz)
- Package Volume: 2,304.75 cm³ (4.5 × 16.5 × 31.0 cm)
- Unit Type: PCE (Piece)
- Units per Package: 1
Package Includes
- 1x Schneider Electric 140NOM21100 DIO head-end adaptor module
- 1x installation documentation
Shipping Options
- FedEx Priority Overnight
- UPS 2-Day Air
- DHL Express Worldwide
- Ground shipping available
- Shipping weight: 482g (includes module and documentation)
GTIN
3595861127265
FAQ
1. What is the part number for this DIO head-end adaptor?
The part number is 140NOM21100.
2. What communication ports does the 140NOM21100 feature?
It features one Modbus Plus RS485 port and one Modbus RS232 port, both using twisted pair single copper cable.
3. What modules are compatible with this adaptor?
It is compatible with 140CRA21120 and 140CRA21110 distributed I/O modules.
Ƙarin ƙayyadaddun bayanai
- Launin toka
- Baƙi
- Fari
- Bej
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
How Do You Fix ControlLogix Redundancy Switchover Failures?
This article examines the hidden causes of Allen-Bradley 1756 redundant CPU switchover failures on oil and gas ski...
-
Why Is INFI90 End-of-Life a Growing Risk for Power DCS?
This article examines ABB Bailey INFI90 end-of-life risks in power DCS environments and presents a three-tier moderni...
-
How Do MTL Intrinsic Safety Barriers Protect Petrochemical DCS Loops?
This article explains how industrial automation teams size MTL intrinsic safety barriers for petrochemical DCS a...
-
How Does Bently 3500 TSI Detect Proximity Probe Faults?
This article explains Bently 3500 TSI proximity probe troubleshooting, technical parameters and calibrated insta...
-
How to Diagnose Yokogawa CENTUM VP FCS Redundancy Faults?
This article explains how industrial automation teams can diagnose and debug Yokogawa CENTUM VP FCS controller redund...
-
How Does Siemens S7-1500 PLC Handle PROFINET Real-Time Jitter?
This article examines measurable PROFINET fault modes on Siemens S7-1500 PLC controllers and provides field-prov...