Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:RAIO-01
RAIO-01 ABB Analog Extension Module Galvanic Isolation 1.5kV
Manufacturer: ABB
Product No.: RAIO-01
Product Type: I/O Extension Module
Product Origin: SE
Payment:T/T, Western Union
Weight: 350g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
ABB RAIO-01 I/O Extension Module
The ABB RAIO-01 is an I/O extension module designed for RMIO board option slots or external mounting via the AIMA-01 I/O Adapter. Supporting bipolar (±0[4]-20 mA, ±0[2]-10 V, ±0-2 V) and unipolar (0[4]-20 mA) inputs, it delivers 12-bit output resolution with 0.024% accuracy. Featuring galvanic isolation and 1.5 kV AC chassis test voltage, this module ensures reliable signal integrity. Weighing 0.35 kg (0.77 lbs), it operates from -20°C to 60°C with IP20 protection.
Technical Specifications
| Parameter | Value |
|---|---|
| Manufacturer | ABB |
| Model | RAIO-01 |
| Product Type | I/O Extension Module |
| Mounting Type | RMIO Board Option Slot or AIMA-01 I/O Adapter |
| Input Types | Bipolar (±0[4]-20 mA, ±0[2]-10 V, ±0-2 V), Unipolar (0[4]-20 mA) |
| Output Type | Unipolar Current |
| Input Impedance | 100 Ω (Current), 200 kΩ (Voltage) |
| Output Resolution | 12-bit (0.024% Accuracy) |
| Signal Isolation | Galvanically Isolated (Inputs, Outputs, Carrier Board) |
| Max Isolation Voltage | 48 V RMS Continuous, 100 V Peak |
| Chassis Isolation Test | 1.5 kV AC (1 second) |
| Power Consumption | 100 mA (5 V), 120 mA (24 V) |
| Inaccuracy | ±0.5% Full Scale @ 25°C |
| Temperature Coefficient | ±100 ppm/°C |
| Operating Temperature | -20°C to 60°C (-4°F to 140°F) |
| Protection Class | IP20 |
| Dimensions (H x D x W) | 16.5 x 11.5 x 0.004 cm |
| Weight | 0.35 kg (0.77 lbs) |
| Estimated Lifetime | 100,000 hours |
| Node ID Range | 1-15 (Rotary Switch) |
Installation & Field Application Guide
- Mount the 0.35 kg module in the RMIO board option slot or connect externally via the AIMA-01 I/O Adapter.
- Set the Node ID (1-15) using the rotary switch before power-up.
- Configure DIP switches for input signal mode (bipolar/unipolar) and level selection.
- Use shielded twisted-pair cable for analog signals. Ground the shield at one end only.
Why Choose the RAIO-01
- 12-bit resolution with 0.024% accuracy delivers precise analog signal processing.
- Galvanic isolation protects the carrier board from field-side voltage transients.
- Flexible input configuration supports bipolar and unipolar signal types.
- DIP switches and rotary node ID simplify field configuration without software.
Field Engineer FAQs
Q1: What is the maximum isolation voltage of the RAIO-01?
A1: The module provides 48 V RMS continuous and 100 V peak isolation. The chassis isolation test voltage is 1.5 kV AC for 1 second.
Q2: How do I set the input signal mode?
A2: Use the DIP switches to select bipolar or unipolar input mode and the desired signal level.
Q3: What is the node ID range and how is it configured?
A3: The node ID range is 1-15, configured via a rotary switch on the module.
Inquiries: sale@etowonauto.com
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
What Makes PLC and DCS Migration Projects Succeed?
Multi-vendor control system migration demands disciplined project management, early interface testing, and structured...
-
How Does GE OPC UA Server Connect Mixed PLC and DCS Systems?
GE OPC UA server helps industrial plants unify fragmented PLC and DCS data through a vendor-neutral standard, coverin...
-
How Does Modular Gas Transmitter Cut Maintenance Costs?
The Honeywell Universal Transmitter offers a modular, multi-sensor platform for gas monitoring in hazardous industria...
-
Why Do Bently Nevada TSI Sensors Need Single-Point Grounding?
Poor grounding in Bently Nevada TSI systems creates millivolt-level noise that masks real vibration signals and trigg...
-
How Does ABB Fieldbus Cut Industrial Automation Wiring Costs?
ABB fieldbus instruments reduce cable costs by 40-55% and enable real-time DCS diagnostics, yet 62% of faults stem fr...
-
Can Wireless Gas Detection Fix Hard-to-Reach Plant Blind Spots?
This article reviews how the Honeywell Universal Transmitter enables wireless gas detection in hard-to-reach hazardou...