Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:330901-00-10-05-01-00
Proximity Probe Bently Nevada 330901-00-10-05-01-00
Manufacturer: Bently Nevada
Product No.: 330901-00-10-05-01-00
Product Type: 3300 NSv Probe
Product Origin: USA
Payment:T/T, Western Union
Weight: 150g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Product Overview
The Bently Nevada 330901-00-10-05-01-00 is a premium non-contact proximity probe engineered as part of the 3300 XL NSv (Narrow System variant) Transducer Series. This specialized eddy current sensor is designed for critical machinery protection, measuring dynamic shaft vibration, axial position, and timing marks on rotating equipment. Optimized for space-constrained installations with extremely small target profiles, its tightly focused electromagnetic field prevents side-view cross-talk from nearby counterbores or structural dividers, making it the ideal selection for fluid-film bearing paths on high-speed pumps, compressors, and small steam turbines.
Technical Configuration
Model Configuration Breakdown
The specific part numbering matrix defines the distinct mechanical and electrical options built into this unit:
- 330901: Core hardware identifier for the high-precision 3300 XL NSv proximity probe system.
- 00: Zero unthreaded length option, providing a fully threaded barrel installation profile.
- 10: Compact 1.0-inch (25.4 mm) case length profile tailored for shallow mounting clearance areas.
- 05: 20-inch (0.5-meter) flexible cable length featuring standard ClickLoc retention mechanism.
- 01: Military-grade miniature coaxial connector delivering an IP67 environmental rating.
- 00: Standard non-hazardous or basic agency approval classification baseline.
Technical Specifications
| Model Designation | 330901-00-10-05-01-00 |
| Product Series | 3300 XL NSv Proximity Transducer System |
| Mechanical Frame | Fully threaded barrel, 1.0-inch case profile |
| Integrated Cable Length | 0.5 meter (20 inches) total length |
| Connection Interface | Miniature coaxial connector with ClickLoc mechanism (IP67) |
| Sensing Tip Material | Polyphenylene Sulfide (PPS), stable against 2.1G vibrations |
| Cable Insulation | Fluorinated Ethylene Propylene (FEP) jacket (resists hydraulic fluids) |
| Thermal Resilience | Sustains -35°C to +177°C continuous exposure |
| Pressure Sealing | Integrated Viton O-ring seals up to 50 PSI differential pressure |
| Max Thread Depth | 9.53 mm |
| Product Net Weight | 85g median mass (Total hardware range: 14g to 150g) |
Installation Guide
Mechanical Threading and Torque Requirements
Thread the 1.0-inch fully threaded probe body straight into the pre-machined mounting bracket. Given its ultra-lightweight design with an 85g median mass, ensure gentle handling during initial insertion. Avoid driving the probe face past the maximum allowable thread depth of 9.53 mm. Once the target electrical gap is calibrated, use a torque wrench to lock the jam nut to exactly 5.1 N·m. Adhering strictly to this rating ensures thread security and prevents thread deformation or galling under high mechanical loads.
Fluid Protection and Pressure Isolation
Verify that the integrated Viton O-ring is seated correctly inside its machined channel before completing insertion. This O-ring maintains a positive seal against pressure differentials up to 50 PSI, preventing aggressive lube oil mist or process hydraulic fluids from weeping past the mounting wall. The external FEP cable jacket provides chemical protection, preventing breakdown from long-term fluid exposure.
Cable Routing and Core Grounding
Route the 20-inch flexible lead line through protective tracking channels toward the remote junction housing. Use standard 14 AWG twisted, shielded instrument wire pairs to extend the signal run from the terminal box to the main Proximitor rack. Keep the shield drain line grounded exclusively at the monitoring card backplane to isolate the displacement metrics from stray field-induced noise.
Engineering Advantages
Compact High-Vibration Resilience
The 330901-00-10-05-01-00 probe features a robust Polyphenylene Sulfide (PPS) tip molded directly onto an advanced stainless steel base assembly. This design allows the sensing face to withstand continuous vibrations up to 2.1G and process temperatures up to 177°C without experiencing structural fatigue or sensor calibration drift.
Military-Grade IP67 Connection Stability
The ClickLoc coaxial connector interface ensures low, stable electrical resistance under harsh industrial field conditions. With an IP67 rating, it prevents moisture and grease entry while resisting loose connection faults caused by high-frequency machine vibration.
Technical FAQs
Q1: What does the "00" unthreaded option indicate regarding the mechanical layout?
A1: The "00" option means the probe body is fully threaded up to the sensing tip shroud, allowing maximum adjustment versatility inside compact or shallow bracket designs.
Q2: Can I splice the 20-inch integrated probe cable directly if it does not reach my panel?
A2: No. The integrated 75 Ω coaxial cable must never be cut or spliced directly. To extend its reach, join the military-grade ClickLoc connector to a matching 75 Ω NSv extension cable of the appropriate system length.
Q3: Why is the maximum thread depth constrained strictly to 9.53 mm?
A3: Limiting the depth prevents the probe casing from extending too far into internal machine cavities, ensuring the tip remains safe from rotating components while providing proper clearance for the lock nut.
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
Best Practices for Integrating AB PLCs with Emerson DCS?
Field‑tested solutions for integrating Allen‑Bradley PLCs with Emerson DCS. Quantifies efficiency losses, analyzes pr...
-
Why Are Isolated Plant Monitoring Systems Still Failing in 2026?
Most process plants still operate disconnected monitoring and control systems, missing subtle mechanical faults that ...
-
Can DeltaV Redundant DCS Eliminate Oil & Gas Shutdowns?
This article examines Emerson DeltaV DCS redundant architecture for oil and gas, presenting outage cost data, 1:1 red...
-
Why Are Legacy PLCs the Biggest Risk in New Energy Smart Factories?
This technical article examines how Allen‑Bradley Safety PLC resolves the safety-efficiency paradox in lithium batter...
-
Can Bently Nevada + GE Fanuc PLC Prevent Mill Shutdowns?
This article examines Bently Nevada sensors integrated with GE Fanuc PLC for predictive maintenance in metallurgy. 20...
-
What Is the Data-Driven Strategy for Guaranteeing Genuine Control Spares?
Fragmented spare parts procurement causes 68% of unplanned plant shutdowns and inflates costs by 22% annually. This e...