Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:PR6423/001-121
PR6423/001-121 Emerson EPRO | 8mm Eddy Current Proximity Sensor
Manufacturer: Emerson
Product No.: PR6423/001-121
Product Type: Eddy Current Sensor
Product Origin: USA
Payment:T/T, Western Union
Weight: 100g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Product Overview
The Emerson EPRO PR6423/001-121 is an 8mm non-contact eddy current proximity sensor engineered for critical turbomachinery protection and vibration monitoring. Designed to measure dynamic radial and axial shaft displacement, position, eccentricity, and rotational speed, it is widely deployed on steam, gas, and hydro turbines, as well as heavy industrial compressors, gearboxes, pumps, and fans. Featuring an M10x1 threaded case (35mm length), a 5.0-meter unarmored PTFE cable with open wire ends, and an IP66-rated stainless steel body, the PR6423/001-121 delivers precise, high-reliability measurements in harsh industrial environments.
Technical Specifications
| Parameter | Specification |
|---|---|
| Product Catalog Number | PR6423/001-121 |
| Manufacturer / Product Family | Emerson EPRO / PR6423 Series |
| Sensor Tip Diameter & Case Thread | 8 mm Tip Diameter | M10x1 Case Threads |
| Case Length (Option A) | 35 mm (A = 1) |
| Adapter Plug (Option B) | Without Adapter Plug (B = 1) |
| Cable Length & Armor (Option C) | 5.0 meters (C = 2) | Unarmored Cable |
| Cable End Termination (Option D) | Open Wire End (D = 1) |
| Linear Measurement Range | 2 mm (80 mils) | Initial Air Gap: 0.5 mm (20 mils) |
| Incremental Scale Factor (ISF) | 8 V/mm (203.2 mV/mil) ± 5% (0 to 45°C) |
| Deviation from Straight Line (DSL) | ± 0.025 mm (± 1 mil) (0 to 45°C) |
| Target Material & Min. Shaft Dia. | 42CrMo4 (AISI/SAE 4140) Ferromagnetic Steel | Min. Shaft Dia. 25 mm (0.79") |
| Enclosure Rating & Construction Materials | IP66 (IEC 60529) | PEEK Tip, Stainless Steel Case, PTFE Cable |
| Operating Temperature Range | Sensor & 1m Cable: -35 to +180°C | Cable & Connector: -35 to +150°C |
| Hazardous Area Certifications | ATEX, IEC-Ex, CSA (Intrinsic Safety 'ia' & Non-sparking 'nA') |
| Approximate Product Weight | 100 grams (3.53 oz) (Sensor with 1m cable base) |
Key Hardware & Operational Features
- Turbomachinery Condition Monitoring: Delivers continuous, high-precision measurement of radial vibration, axial thrust position, phase reference (keyphasor), and eccentricity across critical rotating assets.
- Rugged Industrial Construction: Built with a chemical-resistant PEEK sensor tip, stainless steel threaded body, and high-temperature PTFE cable insulation rated up to 180°C.
- Configured Ordering Options: Features the PR6423 standard configuration with a 35mm case length, unarmored 5.0m integral cable, and open lead wire terminations.
- Hazardous Location Compliance: Fully certified under ATEX, IECEx, and CSA standards for Intrinsic Safety (ia) and Non-sparking (nA) environments (T6/T4/T3 thermal classes).
Installation & Field Wiring Guidelines
1. Sensor Mounting: Thread the M10x1 body into the bracket and set a 0.5 mm air gap facing a 42CrMo4 steel shaft (min. 25 mm dia.).
2. Field Wiring: Route the 5.0m PTFE cable away from high noise lines and connect open ends directly to the signal transmitter terminals.
Frequently Asked Questions (FAQs)
Q1: What is the linear range of PR6423/001-121?
A1: It features a 2 mm (80 mils) linear range with an 8 V/mm (203.2 mV/mil) scale factor.
Q2: What cable options does PR6423/001-121 feature?
A2: It includes a 5.0m unarmored PTFE cable with open wire ends and no adapter plug.
Q3: What certifications apply to PR6423/001-121?
A3: It carries ATEX, IECEx, and CSA approvals for Intrinsic Safety and Non-sparking areas.
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
Can ABB AC500 redundant power eliminate mill downtime?
This technical article examines how ABB AC500 redundant power modules resolve unplanned downtime caused by voltage...
-
Is Your Wastewater Plant Ready for a Data-Driven Upgrade?
This technical article examines the operational bottlenecks of legacy wastewater treatment automation and presents a ...
-
Can Eddy-Current Probes Prevent LNG Compressor Shutdowns?
This technical article examines how Bently Nevada eddy-current proximity probes provide high-precision vibration...
-
Can SIL 3 PLCs Really Slash $1M in Annual Offshore Maintenance?
This technical article examines how Allen‑Bradley GuardPLC SIL 3 safety controllers reduce unplanned offshore downtim...
-
Can Emerson DeltaV DCS Cards Optimize Chemical Safety Loops?
This technical article examines how Emerson DeltaV DCS card upgrades address legacy control limitations in chemical p...
-
Is Partial CNC Board Replacement Better Than a Full System Upgrade?
This technical article examines the dominance of GE Fanuc CNC hardware in heavy-duty automation, supported by field d...