Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:V18345-1004210001
Positioner V18345-1004210001 ABB | 4-20mA
Manufacturer: ABB
Product No.: V18345-1004210001
Product Type: Valve Positioner Module
Product Origin: Sweden
Payment:T/T, Western Union
Weight: 1700g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Product Overview
The V18345-1004210001 is an electro-pneumatic positioner from ABB, designed for precise valve control on linear and rotary actuators. Features 4–20 mA two-wire input, HART FSK communication, ATEX EEx nA II T6 protection, and fail-freeze output. Aluminum IP65/NEMA 4X housing. Weight: 1.7 kg. Certified for SIL2 safety loops.
Technical Specifications
| Parameter | Specification |
|---|---|
| Part Number | V18345-1004210001 |
| Manufacturer | ABB |
| Type | Electro-Pneumatic Positioner (TZIDC) |
| Input Signal | 4–20 mA two-wire, max 25 mA / 30 V |
| Min Input Current | 3.4 mA (without feedback), start from 3.8 mA |
| Communication | HART 5.1, FSK module, LKS local connector |
| Explosion Protection | ATEX EEx nA II T6 (Zone 2) |
| Output / Safe Position | Fail freeze (single or double acting) |
| Output Range | 0–6 bar (0–90 psi) |
| Supply Pressure | 1.4–6 bar (20–90 psi) |
| Air Consumption | <0.03 kg/h / 0.015 scfm |
| Air Capacity (1.4 bar) | 5.0 kg/h = 3.9 Nm³/h = 2.3 scfm |
| Air Capacity (6 bar) | 13 kg/h = 10 Nm³/h = 6.0 scfm |
| Air Quality | DIN/ISO 8573-1 Class 3 (5 µm, 5 mg/m³, oil 1 mg/m³) |
| Housing Material | Aluminum, varnished, RAL 9005 |
| Protection Class | IP65 / NEMA 4X |
| Pneumatic Connections | G 1/4 or 1/4-18 NPT |
| Electrical Connections | 2 threads 1/2-14 NPT or M20x1.5 |
| Screw Terminals | Max 1.0 mm² (options) / 2.5 mm² (analog signal) |
| Digital Input | 24 V DC (12–30 V DC), max 4 mA |
| Digital Output | 5–11 V DC (NAMUR DIN 19234) |
| Load Voltage (20 mA) | 8.7 V DC (non-Ex) / 9.7 V DC (intrinsically safe) |
| Impedance (20 mA) | 435 Ω (non-Ex) / 485 Ω (intrinsically safe) |
| Angle of Rotation | 25–120° (rotary, optional 270°); 25–60° (linear) |
| Travel Limit | 0–100%, min range >20% |
| Travel Time Prolongation | 0–200 seconds per direction |
| Characteristic Deviation | ≤0.5% |
| Tolerance Band | 0.3–10% adjustable |
| Dead Band | 0.1–10% adjustable |
| Resolution | >4000 steps |
| Sample Rate | 20 ms |
| Temperature Influence | ≤0.5% per 10°C |
| Vibration Influence | ≤±1% up to 10 g and 80 Hz |
| Seismic Compliance | DIN/IEC 68-3-3 Class III |
| Ambient Temperature | -40°C to +85°C |
| Humidity (Operational) | 95% annual average, condensation permissible |
| Humidity (Transport/Storage) | 75% annual average, non-condensing |
| Safety | SIL2 safety loops |
| Approvals | ATEX, FM, CSA, IECEx |
| Weight | 1.7 kg |
Installation & Maintenance
Mounting
Mount to linear actuators per DIN/IEC 534/NAMUR or rotary actuators per VDI/VDE 3845. Integral mounting ready. Mechanical position indicator provides visual feedback. Mounting orientation has no effect on performance.
Air Supply
Use instrument air free of oil, water, and dust per DIN/ISO 8573-1 Class 3: max particle 5 µm, density 5 mg/m³, oil 1 mg/m³, dew point 10 K below operating temperature. Do not exceed actuator max operating pressure.
Hazardous Area Installation
ATEX EEx nA II T6 (Zone 2) approved. Ambient temperature limits: T4 -40°C to +85°C, T5 -40°C to +65°C, T6 -40°C to +50°C. Also certified for FM/CSA intrinsically safe and IECEx Ex ib IIC T6 applications.
Engineering Advantages
Fail-Freeze Safety
On electrical power failure, the actuator blocks in its last position (fail freeze). Ensures process continuity and safe operation in critical applications. Certified for SIL2 safety loops.
ATEX Zone 2 Protection
ATEX EEx nA II T6 certification enables installation in Zone 2 hazardous areas. Also certified for FM/CSA intrinsically safe and IECEx Ex ib IIC T6 applications.
Precise Valve Control
Resolution >4000 steps with 20 ms sample rate. Characteristic deviation ≤0.5%. Freely configurable characteristic curves with 20 reference points. HART FSK communication for remote diagnostics.
Technical FAQs
Q1: What is the fail-safe behavior on electrical power failure?
A1: Fail freeze. The actuator blocks in its last position on loss of electrical power. Air is vented from the actuator or the actuator is blocked.
Q2: What explosion protection does this model provide?
A2: ATEX EEx nA II T6 (Zone 2). Also certified for FM/CSA intrinsically safe and IECEx Ex ib IIC T6.
Q3: What communication protocol does this positioner use?
A3: HART 5.1 via FSK module over the 20 mA signal line. Also supports LKS local communication interface.
Ƙarin ƙayyadaddun bayanai
- Azurfa
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
How Can You Tune GE RX3i and RX7i Ethernet for Heavy Industry?
Intermittent Ethernet timeouts on GE RX3i and RX7i controllers are among the hardest faults in heavy process plants, ...
-
Why Does FCS Redundancy Not Protect Your HIS Configuration?
This article examines the operational risks of Yokogawa CENTUM VP HIS lockups and explains why FCS controller re...
-
How Does 1756 Analog I/O Calibration Drift Affect PLC Accuracy?
This article examines calibration drift in Allen-Bradley ControlLogix 1756 analog I/O modules, presenting quanti...
-
Why Do 31% of ABB 800xA S800 IO Hot Swaps Fail in DCS Systems?
ABB 800xA S800 hot swap failures rarely stem from defective hardware. Field data from 142 card replacement jobs shows...
-
How Do You Diagnose Degraded MTL Surge Protection Devices?
This article presents field-proven diagnostic checks, aging benchmarks, and installation rules for MTL surge pro...
-
How Can You Stop Nuisance Trips on Bently Nevada TSI Systems?
Nuisance trips on Bently Nevada TSI racks cost power and oil & gas plants $18,000 to $45,000 per event and occur ...