Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:330103-00-07-10-01-05
New Bently Nevada 330103-00-07-10-01-05 Proximity Probe
Manufacturer: Bently Nevada
Product No.: 330103-00-07-10-01-05
Product Type: Proximity Probe
Product Origin: USA
Payment:T/T, Western Union
Weight: 323g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Bently Nevada 330103-00-07-10-01-05 Overview
The Bently Nevada 330103-00-07-10-01-05 is a high-precision 3300 XL 8mm proximity probe engineered for continuous, industrial-grade machinery monitoring and vibration detection. Featuring a rugged 70mm stainless steel unthreaded housing coupled with a Polyphenylene Sulfide (PPS) tip, this metric probe delivers exceptional chemical and environmental resistance. It provides stable eddy current measurement paths across an active range of 0.25 to 2.3 mm (10 to 90 mils), yielding a highly accurate linear voltage output mapping from -1 to -17 Vdc. Weighing approximately 323g/m, it is heavily favored for mission-critical deployments across volatile, hazardous industrial environments.
Core Technical Advantages
Excellent Thermal & Chemical Endurance
The sensor assembly withstands extreme temperature ranges, supporting standard probe operation from -62°F to +350°F (-52°C to +177°C). The robust PPS tip construction protects the internal sensing coils against corrosive machine fluids and lubricants.
Secure ClickLoc Micro-Coaxial Connection
Equipped with an integrated 1.0-meter coaxial cable terminating in a specialized miniature coaxial ClickLoc connector with a built-in connector protector. This mechanism provides a robust, vibration-resistant locking joint that prevents signal attenuation or intermittent connection dropouts caused by high-frequency machinery harmonics.
Hazardous Area Classification
Fully certified for global hazardous area operation under ATEX, IECEx, and CSA standards (Agency Approval Option 05). It is rated for Zone 0 (AEx/Ex ia IIC T5...T1 Ga) intrinsically safe installations as well as Zone 2 (AEx/Ex nA/ec IIC T5...T1 Gc) safe-operating schemas spanning Groups A through G.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Product Model | 330103-00-07-10-01-05 |
| Product Series Architecture | 3300 XL 8mm Proximity Transducer System (Metric) |
| Manufacturer / Brand | Bently Nevada (Baker Hughes) |
| Housing Sizes | 70mm overall case length; 00mm unthreaded length; M10×1 mechanical thread |
| Linear Measurement Range | 2 mm (80 mils) linear span; from 0.25 to 2.3 mm (10 to 90 mils) |
| Dynamic Signal Output | -1 Vdc to -17 Vdc linear voltage scale |
| Optimal Sensor Gap Calibration | -9 Vdc electrical bias point (matching 50 mils / 1.27 mm center gap) |
| Electrical Resistive Accuracy | 7.59 Ω ± 0.50 Ω nominal tolerance bounds |
| Integrated Cable Layout | 1.0-meter (3.3 feet) standard coaxial line with miniature ClickLoc connector and protector |
| Humidity & Environmental Drift | <3% Average Scale Factor (ASF) change when exposed to 93% RH for up to 56 days |
| Net Mass Weight | 323 grams per meter (approx. 0.323 kg/m density profile) |
| Explosion Protection Codes | Zone 0: AEx/Ex ia IIC T5...T1 Ga | Zone 2: AEx/Ex nA/ec IIC T5...T1 Gc |
Installation & Engineering Guide
Mechanical Alignment and Gap Setup
Mount the 70mm probe body securely through the machine casing wall using the M10×1 thread profile, ensuring a maximum length of thread engagement of 15 mm. Adjust the physical gap distance relative to the target shaft surface until your digital voltmeter registers exactly -9 Vdc at the Proximitor sensor output terminal, validating the perfect 50 mils center operating gap.
Field Extension Wiring Parameters
When extending the sensor loop to your central control cabinet or monitoring rack, use a 3-conductor shielded triad wire layout (0.2 to 1.5 mm² or 16 to 24 AWG recommended). Keep the total field extension length restricted within a maximum wiring threshold of 305 meters (1,000 feet) between the 3300 XL Proximitor Sensor and the monitor to manage high-frequency signal rolloff.
Environmental Limitations & Sealing
The module features premium differential pressure sealing between the probe tip and case utilizing a Viton® O-ring. However, these units are not pressure tested prior to shipment; contact the custom design department if application-specific verification is required. Avoid exposing the coaxial assembly to temperatures below -34°C (-30°F) to prevent premature failure of the pressure seal.
Technical FAQs
Q1: What does the 323g/m physical weight specification imply for field engineering?
A1: The 323g/m rating indicates the exact hardware density profile of the combined probe body and shielded coaxial line, giving installation engineers structural data for calculating strain relief bracket loads on long cable runs.
Q2: Can the 330103-00-07-10-01-05 probe handle high-pressure fluid environments out of the box?
A2: While it features an integrated Viton® O-ring assembly for robust differential pressure isolation, the default configuration is not pressure-tested prior to shipment. Specific custom pressure testing must be requested manually.
Q3: How does high relative humidity affect the operational accuracy of this 8mm probe?
A3: The probe features a hermetically sealed assembly that restricts the Average Scale Factor (ASF) drift to less than 3% even under continuous exposure to 93% relative humidity conditions for up to 56 days per IEC standard 68 2 3.
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
Me Ya Sa Ya Kamata a Hada PLC da DCS don Ajiya a Smart Grid?
Wannan labarin yana bincika yadda haɗaɗɗen GE Fanuc 90 PLC da Emerson DCS ke magance cikas na ajiya a matakin hanyar ...
-
Ka makale a cikin samarwa rabin-atomatik mai dogaro da hannu? Gwada haɗaɗɗen PLC-DCS mai araha.
Masu kera sinadarai masu ƙaramin girma na iya rungumar Industry 4.0 ba tare da tsadar da ta wuce misali ba. Wannan ha...
-
Shin ABB Marine PLC Na Iya Jure Jijjigar 50g a Teku?
Wannan labarin yana bincika yadda Emerson Kappa DCS da ABB Marine PLC ke warware matsalolin sarrafa tasoshin sinadara...
-
Za A Iya Rage Lokacin Tsayawar Injin da Kashi 70% Ta Amfani da Kayan Gaskiya?
Tsufar kayan aikin PLC da DCS na jiki su ne ke jawo mafi yawan tsayawar aiki ba tare da shiri ba. Wannan jagorar tana...
-
Shin Haɗa PLC-DCS na Daga Masu Kera Daban‑daban Zai Iya Magance Keɓantattun Bayanai a Smart Port?
Wannan maƙalar fasaha tana nazarin yadda haɗin gwiwar tsarin GE Fanuc RX7i PLCs, Allen‑Bradley HMIs da dandamalin Eme...
-
Zai Yiwu A Hada PLC da DCS Daga Masu Kera Daban-Daban Su Aiki Cikin Santsi?
Wannan labarin yana nazarin tasirin aiki na tsarin kula da masana’antu iri-iri, yana auna asarar lokacin tsayuwar aik...