Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:MTL5024
MTL5024 Hazardous Area Solenoid Driver - MTL Instruments
Manufacturer: MTL
Product No.: MTL5024
Product Type: Control Driver
Product Origin: USA
Payment:T/T, Western Union
Weight: 110g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
MTL5024 Hazardous Area On/Off Controller
The MTL5024 from MTL Instruments provides reliable control of hazardous area devices from safe area signals. This single-channel interface drives solenoids, alarms, LEDs and other low-power devices with intrinsic safety. Featuring phase reversal capability, it offers flexible operation for various control applications in explosive atmospheres.
Key Technical Specifications
- Brand: MTL Instruments
- Model: MTL5024
- Product Type: Hazardous Area On/Off Controller
- Channels: One channel
- Output Current: 45mA maximum
- Phase Reversal: User selectable
- Supply Voltage: 20 to 35V DC
Hazardous Area Certification
- Load Location: Zone 0, IIC, T4-T6 hazardous area
- Division Rating: Division 1, Group A hazardous location
- The MTL5024 maintains intrinsic safety for connected devices
- It enables safe operation of loads in explosive atmospheres
Input Compatibility
- Input Types: Volt-free contacts, open-collector transistors, logic signals
- Normal Phase: Output on when switch closed, transistor on, or <1.4V input
- Reverse Phase: Output off under same input conditions
- Input Threshold: Output off when >4.5V applied to input
- Control Terminals: Terminal 11 (Control –ve), Terminal 12 (Control +ve)
Output Performance
- Minimum Output Voltage: 12.85V at 45mA
- Maximum Output Voltage: 25V
- Current Limit: 45mA maximum for safety compliance
- Output Terminals: Terminal 1 (Output –ve), Terminal 2 (Output +ve)
- Suitable for solenoids, alarms, LEDs and low-power devices
Power Requirements
- Supply Voltage: 20 to 35V DC operating range
- Current Consumption: 100mA at 24V maximum
- Power Dissipation: 1.4W typical with solenoid valve
- Worst Case Dissipation: 2.0W maximum
- Supply Terminals: Terminal 13 (Supply –ve), Terminal 14 (Supply +ve)
Safety Parameters
- Safety Voltage: 25V maximum
- Internal Resistance: 170Ω
- Safety Current: 147mA maximum
- Isolation Voltage: Um = 250V rms or DC
- Complete protection for hazardous area operation
Frequently Asked Questions
-
What devices can the MTL5024 control?
It drives solenoids, alarms, LEDs and other low-power intrinsically safe devices. -
How does phase reversal work?
A switch on the module base selects which input phase drives the output on. -
What input signals are compatible?
It accepts volt-free contacts, open-collector transistors, and logic signals. -
Is this suitable for solenoid valve control?
Yes, it is designed for solenoid control with typical 1.4W power dissipation.
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
How Does the Bently Nevada 3500/42M Vibration Module Drift?
This technical guide examines the Bently Nevada 3500/42M vibration module within industrial automation architect...
-
What Causes IC694MDL Fault Codes in GE RX3i PLC Systems?
This guide explains GE RX3i IC694MDL discrete I/O fault codes, key electrical parameters, ESD and torque requirements...
-
What CFC Rules Cut PCS7 Batch Abort Rates Fast?
This article presents enforceable CFC programming governance rules for Siemens PCS7 DCS batch plants, covering b...
-
What Makes the 1769-L3ER Ideal for Compact Skid Automation?
This guide explains how the Allen-Bradley 1769 CompactLogix L3ER bridges the gap between micro PLCs and large DC...
-
Why Do SIL3 Safety Interlocks Still Trip in Industrial Plants?
This article reviews Honeywell Safety Manager SIL3 SIS architecture, wiring and cabinet installation rules, PFDa...
-
How Does Poor Grounding Cause 4-20mA Signal Drift?
This guide explains how MTL signal isolators fail through distortion, drift and EMI in PLC and DCS loops, then d...