Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:IS200EPSMG2A
IS200EPSMG2A Power Supply | GE EX2100 Regulator Control
Manufacturer: General Electric
Product No.: IS200EPSMG2A
Product Type: Option Board
Product Origin: USA
Payment:T/T, Western Union
Weight: 900g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Product Overview
The GE IS200EPSMG2A Exciter Power Supply Module delivers reliable DC power for EX2100 regulator control systems. This module converts DC link bus voltage into the multiple outputs required for turbine excitation control. It pairs with the IS200EPSDG_A daughter board and supports simplex or redundant regulator configurations.
Core Functionality
The IS200EPSMG2A integrates a buck regulator and a push-pull inverter. The buck regulator converts input voltage to a 50Vdc intermediate stage. The push-pull inverter then generates the required multiple output voltages with high-voltage isolation via the internal transformer. The EPSD daughter board modifies the power input path to accept higher voltages and provides fuse protection between the DC link and buck regulator.
Technical Specifications
| Parameter | Value |
| Part Number | IS200EPSMG2A |
| Manufacturer | General Electric |
| Series | EX2100 |
| Product Type | Exciter Power Supply Module |
| Output Voltages | +5 Vdc, ±15 Vdc, +24 Vdc |
| Contact Wetting Supply | Isolated +70 Vdc |
| IGBT Gate Supply | Isolated 20 Vac |
| Ground Detector Supply | ±55 Vdc |
| Dimensions (H x W) | 15.9 x 17.8 cm |
| Weight | 0.9 kg (2 lbs) |
| Operating Temperature | -30°C to +65°C |
| Functional Revision | A |
| Reference Manual | GEI-100462A / GEH-6632 |
| Country of Origin | United States |
Installation Guide
Mount the IS200EPSMG2A in the IS200ERBPH_A Exciter Regulator Backplane (ERBP) for simplex systems. For redundant configurations, install one in ERBP (M1) and a second in IS200ERRBH_A (ERRB, M2/C). Ensure the EPSD daughter board is properly seated before insertion. Secure the module with the backplane connectors. Verify input voltage from the DC link meets specification. Route output cables to terminal boards and external modules per GEI-100462A guidelines.
Engineering Advantages
The IS200EPSMG2A delivers isolated +70Vdc for contact wetting, ensuring reliable switching of field contacts. The isolated 20Vac supply powers IGBT gates with robust isolation. ±55Vdc supports ground detector circuits on option cards. The EPSD board increases creepage and clearance distances for higher voltage acceptance. This module supports both simplex and redundant EX2100 regulator architectures, providing flexibility for system design.
Technical FAQs
Q1: What is the difference between EPSMG1 and EPSMG2?
A1: EPSMG1 powers EX2100 excitation control (M1, M2, C controllers). EPSMG2 powers EX2100 regulator control. EPSMG2 includes the EPSD daughter board and accepts higher input voltages.
Q2: Is the IS200EPSMG2A backward compatible with non-A revisions?
A2: No. The "A" revision indicates functional changes. This model is not backward compatible with earlier IS200EPSMG2 versions.
Q3: What external modules receive ±24Vdc from this supply?
A3: The ±24Vdc (P24B/N24B) powers fans, relays, and the DC feedback board in the regulator control system.
Ƙarin ƙayyadaddun bayanai
- Kore
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
Why Hybrid AB PLC + ABB DCS Beat Single-Vendor Systems?
This article examines how hybrid integration of Allen‑Bradley PLC and ABB DCS overcomes single-vendor limitations in ...
-
PLC, DCS, or TSI: Which Controls Fit Your Plant?
This article reviews five trusted industrial control system combinations from Allen‑Bradley, ABB, Emerson, GE Fanuc, ...
-
How to Integrate GE Fanuc PLC with ABB DCS Using OPC UA?
This article delivers a practical guide for integrating GE Fanuc PLCs with ABB DCS using OPC UA in Industry 4.0 envir...
-
Can DCS-PLC Integration Cut Chemical Plant Downtime by 37%?
This technical article examines how strategic integration of Emerson DeltaV DCS and Allen-Bradley PLC resolves instab...
-
How to Source Genuine PLC/DCS Spares and Avoid Counterfeit Risks?
Global manufacturers face rising counterfeit PLC and DCS modules that cause signal deviations, unplanned failures, an...
-
Can Bently Nevada-PLC-DCS Integration End Unplanned Downtime?
This article examines how integrating Bently Nevada TSI sensors with PLC and DCS systems resolves industrial data fra...
