Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:V18345-1010251001
Intelligent Positioner IP65 | ABB TZIDC-120 V18345-1010251001
Manufacturer: ABB
Product No.: V18345-1010251001
Product Type: Valve Positioner Module
Product Origin: Sweden
Payment:T/T, Western Union
Weight: 1700g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
ABB V18345-1010251001 TZIDC-120 Intelligent Positioner
Product Overview
ABB V18345-1010251001 is a TZIDC-120 intelligent positioner with configurable indicator and operator panel. Features varnished aluminum case IP65 (NEMA 4X) for mounting to linear actuators per DIN/IEC 534/NAMUR or rotary actuators per VDI/VDE 3845. Accepts 4-20mA two-wire input with LKS adapter connector plug. Single acting fail freeze action. Cable connection M20x1.5 and air pipe 1/4-18 NPT. Includes plug-in analog position feedback module 4-20mA.
Model Number Decoder
| Position | Code | Meaning |
|---|---|---|
| Base | V18345 | TZIDC-120 Intelligent Positioner |
| Case/Mounting | 2 | Varnished aluminum IP65, DIN/IEC 534/NAMUR or VDI/VDE 3845 |
| Input/Communication | 1 | 4-20mA two-wire with LKS adapter connector |
| Explosion Protection | 0 | Without |
| Output/Safe Position | 2 | Single acting, fail freeze |
| Connections | 5 | Cable M20x1.5, Air 1/4-18 NPT |
| Option Modules | 1 | Plug-in analog position feedback 4-20mA |
| Mech Feedback | 0 | Without |
| Design | 1 | Standard |
Technical Specifications
| Parameter | Value |
|---|---|
| Brand | ABB |
| Model | V18345-1010251001 |
| Type | TZIDC-120 Intelligent Positioner |
| Action | Single Acting, Fail Freeze |
| Signal Range | 4 to 20 mA two-wire |
| Supply Pressure | 1.4 to 6 bar (20 to 90 psi) |
| Air Consumption | < 0.03 kg/h (0.015 scfm) |
| Action Signal | Direct 4-20mA = 0-100%, Reverse 20-4mA = 0-100% |
| Characteristic Curve | Linear, equal percentage 1:25/1:50/25:1/50:1, 20 points |
| Characteristic Deviation | ≤ 0.5% |
| Tolerance Band | 0.3 to 10% adjustable |
| Dead Band | 0.1 to 10% adjustable |
| Resolution A/D | > 4000 steps |
| Sample Rate | 20 ms |
| Temp Influence | ≤ 0.5% per 10°C |
| Vibration Influence | ≤ ±1% up to 10g and 80Hz |
| Seismic | DIN/IEC 68-3-3 Class III |
| Mounting Orientation | No effect |
| Electrical Connection | M20x1.5 |
| Pneumatic Connection | 1/4-18 NPT |
| Protection Class | IP65, NEMA 4X |
| Weight | 1.7 kg (3.75 lbs) |
Installation
Mount on linear actuators per DIN/IEC 534/NAMUR or rotary actuators per VDI/VDE 3845. Ready for integral mounting. Connect 4-20mA two-wire input with LKS adapter. Wire electrical connection at M20x1.5. Connect air supply at 1/4-18 NPT with 1.4 to 6 bar pressure. Do not exceed maximum operating pressure of the actuator. Configure characteristic curve via 20 reference points. Verify IP65 seal after installation.
Features
TZIDC-120 intelligent positioner with configurable indicator and operator panel. Single acting fail freeze action. 4-20mA two-wire input with LKS adapter. Plug-in analog position feedback 4-20mA. Characteristic deviation ≤0.5%. Resolution >4000 steps. Sample rate 20 ms. Air consumption less than 0.03 kg/h independent of supply pressure. Seismic rated per DIN/IEC 68-3-3 Class III. No effect from mounting orientation. Aluminum case with epoxy resin varnish IP65 NEMA 4X. Weight 1.7 kg.
FAQ
Q1: What is the action type and fail position?
A1: Single acting with fail freeze action. In case of electrical failure, the actuator is blocked or air is vented depending on configuration.
Q2: What is the air consumption and supply pressure?
A2: Air consumption less than 0.03 kg/h independent of supply pressure. Supply pressure range 1.4 to 6 bar (20 to 90 psi).
Q3: What is the characteristic deviation and resolution?
A3: Characteristic deviation ≤0.5%. Resolution >4000 steps. Sample rate 20 ms. Tolerance band adjustable 0.3 to 10%. Weight 1.7 kg.
Ƙarin ƙayyadaddun bayanai
- Azurfa
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
What Logic Changes Cut SIS False Trips by 94%?
This article examines practical logic modification and parameter tuning methods for ABB 800xA HI SIL3 safety ins...
-
Why Do FTE Redundancy Failovers Lock Up in DCS?
Honeywell FTE delivers sub-500 ms failover for Experion PKS, yet field records show 38% of outages stem from installa...
-
How Does the Bently Nevada 3500/42M Vibration Module Drift?
This technical guide examines the Bently Nevada 3500/42M vibration module within industrial automation architect...
-
What Causes IC694MDL Fault Codes in GE RX3i PLC Systems?
This guide explains GE RX3i IC694MDL discrete I/O fault codes, key electrical parameters, ESD and torque requirements...
-
What CFC Rules Cut PCS7 Batch Abort Rates Fast?
This article presents enforceable CFC programming governance rules for Siemens PCS7 DCS batch plants, covering b...
-
What Makes the 1769-L3ER Ideal for Compact Skid Automation?
This guide explains how the Allen-Bradley 1769 CompactLogix L3ER bridges the gap between micro PLCs and large DC...