Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:1771-ID
Input Module 6 Point 120V AC/DC | Allen-Bradley 1771-ID
Manufacturer: Allen-Bradley
Product No.: 1771-ID
Product Type: Discrete Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 450g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
1771-ID Allen-Bradley PLC 5 Individually Isolated Discrete Input Module – 6 Inputs
The Allen-Bradley 1771-ID is a PLC 5 individually isolated discrete input module with 6 input channels. Operates with a 92-138V AC/DC range and 120V AC/DC voltage category. Weight is 0.45 kg.
Product Information
| Manufacturer | Allen-Bradley |
| Product Line | PLC 5 |
| Part Number | 1771-ID |
| Module Type | Individually Isolated Discrete Input Module |
| Number of Inputs | 6 |
| Voltage Category | 120V AC/DC |
| Field Wiring Arm | 1771-WD |
| Compatible Chassis | 1771 I/O Chassis |
| Keying | Between Pins 4 and 6; Between Pins 28 and 30 |
| UPC | 662468205511 |
| Weight | 0.45 kg (1.00 lbs) |
Input Specifications
| AC Operating Voltage | 92-138V AC |
| DC Operating Voltage | 92-138V DC |
| AC Input Frequency | 47-63 Hz |
| Nominal Input Current | 8 mA at 120V AC / 8 mA at 120V DC |
| AC Signal Delay (On/Off) | 24 ms (±10 ms) |
| DC Signal Delay (On) | 10 ms (±4 ms) |
| DC Signal Delay (Off) | 20 ms (±9 ms) |
| Max AC/DC Off-State Current | 1.7 mA |
Power Specifications
| Backplane Current | 74 mA |
| Power Dissipation | 0.4-4.4 W |
| Thermal Dissipation | 1.3-15.0 BTU/hr |
| Wiring Arm Screw Torque | 7-9 Inch-Pounds |
Features
- 6 individually isolated discrete input channels
- 92-138V AC/DC operating voltage range
- 120V AC/DC voltage category
- AC input frequency 47-63 Hz
- Compatible with 1771 I/O chassis
- 1771-WD field wiring arm for module replacement
- Individual channel isolation for enhanced safety
FAQs
Q1: How many inputs does the 1771-ID provide?
A1: 6 individually isolated discrete input channels.
Q2: What is the operating voltage and signal delay?
A2: 92-138V AC/DC with AC delay of 24 ms (±10 ms), DC on delay of 10 ms (±4 ms), and DC off delay of 20 ms (±9 ms).
Q3: What wiring arm and backplane current are required?
A3: 1771-WD field wiring arm with 74 mA backplane current.
Ƙarin ƙayyadaddun bayanai
- Baƙi
- Kore
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
When Should You Replace a Yokogawa Analog IO Card?
This article breaks down Yokogawa analog AI/AO card calibration tolerances, drift aging benchmarks, and formal replac...
-
What Performance Gains Does S7-1500 Offer Over Legacy S7 PLCs?
Legacy Siemens S7-300 and S7-400 PLCs face spare-part shortages, rising failure rates and limited network capability,...
-
What Logic Changes Cut SIS False Trips by 94%?
This article examines practical logic modification and parameter tuning methods for ABB 800xA HI SIL3 safety ins...
-
Why Do FTE Redundancy Failovers Lock Up in DCS?
Honeywell FTE delivers sub-500 ms failover for Experion PKS, yet field records show 38% of outages stem from installa...
-
How Does the Bently Nevada 3500/42M Vibration Module Drift?
This technical guide examines the Bently Nevada 3500/42M vibration module within industrial automation architect...
-
What Causes IC694MDL Fault Codes in GE RX3i PLC Systems?
This guide explains GE RX3i IC694MDL discrete I/O fault codes, key electrical parameters, ESD and torque requirements...