Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:IC670MDL930
IC670MDL930 GE Fanuc Field Control 8 Point Relay Module
Manufacturer: General Electric
Product No.: IC670MDL930
Product Type: Relay Output Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 300g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Product Overview
The GE Fanuc IC670MDL930 is an 8-point individually isolated discrete relay output module belonging to the Field Control I/O system. Engineered for high-density, reliable switching in industrial automation and process control architectures, this module provides flexible AC/DC load driving for field devices such as solenoids, motor starters, indicator lights, and actuators.
Featuring a total of eight channels organized into six (6) Form A (Normally Open) contacts and two (2) Form C (SPDT / Normally Open & Normally Closed) contacts, the IC670MDL930 delivers channel-to-channel isolation with built-in RC snubber transient protection (R=47.5 Ω, C=0.022 µF). With a compact design weighing approximately 0.30 kg (0.66 lbs), it operable across 5–30 V DC, 31–125 V DC, and 5–265 V AC, supporting up to 2.0 A continuous load per channel (16 A maximum per module) while drawing a maximum of 313 mA from the Bus Interface Unit (BIU) logic supply.
Core Technical Advantages
- Individual Channel Isolation: Each output contact is independently isolated (250 VAC continuous, 1500 VAC for 1 min), preventing ground loops and protecting logic-side electronics.
- Mixed Contact Configuration: Integrates six Form A (N.O.) and two Form C (N.O./N.C.) silver-alloy contacts for versatile logic and safety circuit wiring.
- Integrated RC Snubber Suppression: Built-in snubber networks across contacts mitigate high-frequency voltage spikes caused by inductive load switching without external components.
- Comprehensive Diagnostic LEDs: Features channel-level status LEDs alongside power indicators to simplify field troubleshooting and signal verification.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Brand / Manufacturer | GE Fanuc |
| Catalog Part Number | IC670MDL930 |
| Product Family | Field Control I/O System |
| Module Type | Isolated Discrete Relay Output Module |
| Number of Channels | 8 channels (Individual channel isolation) |
| Contact Forms | 6 × Form A (N.O.) / 2 × Form C (N.O. & N.C.) |
| Nominal Operating Voltages | 5 / 24 / 125 V DC; 120 / 240 V AC (47–63 Hz) |
| Operating Voltage Ranges | 0 to 130 V DC / 0 to 265 V AC |
| Maximum Load Current (AC) | 2.0 A per point (5 to 265 V AC) |
| Maximum Load Current (DC) | 2.0 A per point (5 to 30 V DC); 0.2 A per point (31 to 125 V DC) |
| Total Module Current Capacity | 16 A maximum (resistive load) |
| Minimum Load Current | 10 mA per point |
| Maximum Inrush Current | 5 A for 20 ms |
| BIU Current Consumption | 313 mA maximum from BIU logic supply |
| Relay Technology & Material | Fixed coil, moving armature; Silver Alloy contacts (0.2 Ω resistance) |
| On / Off Response Time | 10 ms maximum transition time |
| Maximum Switching Frequency | 20 cycles/minute (inductive loads) |
| Contact Life Expectancy | Mechanical: 20 × 10⁶ ops; Electrical: 10⁵ ops at rated resistive load |
| Internal Protection & Fusing | RC Snubber (R=47.5 Ω, C=0.022 µF); No internal fuse |
| Isolation Voltage | 250 VAC continuous / 1500 VAC for 1 min (Input to Logic / Group to Group) |
| Shipping Weight | Approx. 0.30 kg (0.66 lbs) |
Installation & Wiring Guidelines
- Field Base Mounting: Snap the IC670MDL930 module onto the matching Field Control terminal base, ensuring backplane connectors seal firmly to enable BIU power and data flow.
- External Power Distribution: Connect an external AC or DC field power source to drive loads connected through relay contacts. Ensure proper external fusing since the module does not contain internal fuses.
- Inductive Load Protection: While built-in RC snubbers suppress standard noise transients, high-inductance DC loads should utilize secondary flyback diodes installed directly across the load terminals.
Technical FAQs
Q1: What are the current rating limits for DC loads on the GE Fanuc IC670MDL930?
A1: Each contact supports 2.0 A for low-voltage DC (5 to 30 V DC), but drops to 0.2 A max for high-voltage DC applications (31 to 125 V DC).
Q2: Does the IC670MDL930 module provide individual channel isolation?
A2: Yes, all 8 channels are individually isolated up to 250 VAC continuous (1500 VAC for 1 minute) between groups, logic, and frame ground.
Q3: What power does the module draw from the Field Control BIU backplane?
A3: The module draws up to 313 mA from the Bus Interface Unit (BIU) power supply to energize the relay coils.
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
Does New GE Fanuc 90-30 Backplane Stabilize Cement Kilns?
This technical article examines how brand-new GE Fanuc 90-30 PLC backplane components deliver measurable reliability ...
-
Why 28% of Gas Turbine Trips Stem from Monitoring Failures?
Combined cycle gas turbines demand micron-level shaft monitoring to prevent vibration resonance and unplanned outages...
-
Can ABB AC500 redundant power eliminate mill downtime?
This technical article examines how ABB AC500 redundant power modules resolve unplanned downtime caused by voltage...
-
Is Your Wastewater Plant Ready for a Data-Driven Upgrade?
This technical article examines the operational bottlenecks of legacy wastewater treatment automation and presents a ...
-
Can Eddy-Current Probes Prevent LNG Compressor Shutdowns?
This technical article examines how Bently Nevada eddy-current proximity probes provide high-precision vibration...
-
Can SIL 3 PLCs Really Slash $1M in Annual Offshore Maintenance?
This technical article examines how Allen‑Bradley GuardPLC SIL 3 safety controllers reduce unplanned offshore downtim...