Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:IC200CBL655
IC200CBL655 GE Fanuc | DataPanel 45/65/85 Expansion Cable
Manufacturer: General Electric
Product No.: IC200CBL655
Product Type: Communication Cable
Product Origin: USA
Payment:T/T, Western Union
Weight: 150g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Product Overview
The GE Fanuc IC200CBL655 is an RS-422 communication cable designed for DataPanel 45/65/85 operator interface modules (DP150, DP160, DP240E). This 25-pin expansion cable connects DataPanel I/O modules to Mitsubishi FX controllers via the Prog Port, enabling reliable serial communication in industrial automation systems.
Core Functionality
The IC200CBL655 transmits RS-422 signals between DataPanel operator interfaces and Mitsubishi FX PLCs. It uses Tx, Rx, Signal, and Ground pins for controller communication. The cable supports real-time data display, tag updates, and controller interaction through the DataPanel's built-in keypad and graphical interface. It is not supplied with DataPanel modules and must be ordered separately.
Technical Specifications
| Parameter | Value |
| Part Number | IC200CBL655 |
| Manufacturer | GE Fanuc |
| Cable Type | RS-422 Communication Cable |
| Connector Type | 25-pin D-type (one end) |
| Compatible PLC | Mitsubishi FX Series |
| Compatible HMIs | DataPanel 45/65/85 (DP150, DP160, DP240E) |
| Connection Port | Prog Port (Mitsubishi FX) |
| Application | Controller communication |
| Weight | Approx. 0.15 kg (0.33 lbs) |
Installation Guide
Connect the 25-pin D-type connector to the Mitsubishi FX controller Prog Port. Connect the other end to the DataPanel communication port. Ensure the RS-422 pins (Tx, Rx, Signal, Ground) are properly aligned. Secure connector screws for reliable connection. Verify cable routing away from high-voltage sources. Configure the DataPanel communication settings to match the FX PLC parameters.
Engineering Advantages
This cable provides reliable RS-422 communication between GE Fanuc DataPanels and Mitsubishi FX PLCs. The 25-pin D-type connector ensures secure and repeatable connections. The cable supports real-time data display and tag updates on DataPanel graphical interfaces. It enables direct controller communication without additional protocol converters.
Technical FAQs
Q1: Compatible DataPanel models?
A1: DataPanel 45/65/85 series including DP150, DP160, and DP240E operator interface modules.
Q2: Which PLCs are supported?
A2: Mitsubishi FX series PLCs via the Prog Port. Uses RS-422 communication protocol.
Q3: Cable included with DataPanel?
A3: No. The IC200CBL655 must be ordered separately from the GE Fanuc accessories catalog.
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
Can Full-Cycle Data Recording Solve Hidden PLC and DCS Faults?
This article examines how GE full-cycle data recording addresses the critical blind spots in traditional PLC and DCS ...
-
How Can Smart Sensor Maintenance Cut False Alarms by 71%?
This article presents a data-driven approach to gas sensor lifecycle management for hazardous area monitoring instrum...
-
Can Standardized Engineering Cut Factory Upgrade Costs by 40%?
This article presents a data‑driven alternative to full control system replacements in brown‑field plants. Allen‑Brad...
-
Choosing the Right Gas Detector for Chemical Safety?
This article examines the operational and financial impact of unreliable gas-sensing hardware in chemical process pla...
-
Is Mixed-Plant Data Fragmentation Costing You More?
Hybrid manufacturing facilities often lose nearly one-third of production data across disjointed PLC and DCS systems,...
-
Can Transient Monitoring Prevent Rotating Machinery Failures?
This technical article examines the critical role of transient data capture in rotating machinery protection, highlig...
