Tsallake zuwa abun ciki
Kayan aikin sarrafa kansu, isarwa a ko’ina cikin duniya
Tsallaka zuwa bayanin kaya
1 na 3

SKU:FC-TSDI-1624C

Honeywell FC-TSDI-1624C Safety Manager Input FTA Board

Ragowar raka'a 8 kaɗai
  • Manufacturer: Honeywell

  • Product No.: FC-TSDI-1624C

  • Product Type: Input Module

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 200g

  • Shipping port: Xiamen

  • Warranty: 12 months

Dokar Mayar da Kaya na Kwanaki 30 · Garantin Watanni 12
  • Isarwa Cikin Gaggawa
  • Tallafi na awa 24 a rana, kwana 7 a mako
  • Tabbacin Inganci

Bayani

Product Overview

The FC-TSDI-1624C is a Honeywell Field Termination Assembly (FTA) providing safe, current-limited interfacing for 16 digital inputs. It protects core safety systems in Class I, Division 2 hazardous locations and supports redundant SDI-1624 modules via SICC-0001/Lx cables.

Core Features

  • 16 Channels: Configured as 2 isolated groups of 8 channels.
  • Fault Isolation: Each group is protected by a 250 mA fuse in the common + line.
  • Redundancy Support: Interfaces directly with a redundant pair of SDI-1624 modules.
  • Industrial Mounting: Fits standard TS32 and TS35 × 7.5 DIN rails.

Technical Specifications

Parameter Data
Model Numbers FC-TSDI-1624C / FS-TSDI-1624C
Input Voltage 24 V DC (-15% to +30%)
Input Current ≤ 15 mA at 24 V DC
Igniting Current < 100 mA per channel at 24 V DC +30%
Fuse Specifications 250 mA, 400 V AC/DC (SOC SHV12), Max 175 mA output
Dimensions / Rail Length 170 × 70 × 60 mm / 171 mm rail length
Wire Size / Torque Max 2.5 mm² (AWG 14) / 0.5 Nm (0.37 ft.-lb)
Approvals CE, TUV, UL, CSA, FM

Installation & Field Circuit Data

  • Strip Length: Wire strip length must be exactly 7 mm (0.28 in).
  • Hydrogen Loops (Group A & B): Max 250 Ω resistance, 8 mH inductance, 0.3 µF capacitance.
  • Non-Hydrogen Loops (Group C & D): Min 15 kΩ resistance, 22 mH inductance, 7 µF capacitance.

Technical FAQs

Q1: What does the "C" suffix mean?
A1: Conformal Coating. It shields the internal circuits from humidity and harsh chemical contaminants.

Q2: Why is the continuous output capped at 175 mA for a 250 mA fuse?
A2: It provides a strict safety margin to prevent thermal fatigue and false trips during continuous load.

Q3: Does it support non-redundant installations?
A3: Yes. It works with a single SDI-1624 safety card, keeping the second port open for future upgrades.

🏷️ Tags: Input Module
  • Ruwan lemu

Sikeli (V/f)

Vector

mai amfani da wutar AC

  • Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
  • Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
  • Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
  • Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
  • Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.

Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.

Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.

Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

Duba bayanin samfur

TABBTAR DA INGANTACCEN AIKIN NA'URORI

Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.