Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:IC200MDL930
General Electric IC200MDL930 | Relay Output Module
Manufacturer: General Electric
Product No.: IC200MDL930
Product Type: Relay Output Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 450g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
General Electric IC200MDL930 Versamax Relay Output Module
The General Electric IC200MDL930 is an 8-point relay output module for Versamax I/O systems. Features 8 individually isolated Normally Open (Form A) contacts.
Key specifications
- Brand: General Electric / Emerson Automation
- Series: Versamax
- Part number: IC200MDL930
- Points: 8 relay outputs
- Contact form: Normally Open (Form A)
- Relay type: Fixed coil, moving armature
- Contact material: Silver alloy
- Weight: 0.45 kg (approx)
Voltage & current ratings
- DC voltage range: 0 to 125V DC (5/24/125V nominal)
- AC voltage range: 0 to 265V AC at 47-63Hz (120/240V nominal)
- Current rating (AC): 2.0A max for 5-265V AC (resistive)
- Current rating (DC 5-30V): 2.0A max (resistive)
- Current rating (DC 31-125V): 0.2A max (resistive)
- Minimum current: 10mA per point
Response & power
- Response time: 10 ms max (on/off)
- Switching frequency: 20 cycles per minute (inductive loads)
- Backplane current: 243 mA typical, 435 mA max
- Isolation: 250V AC continuous, 1500V AC for 1 minute
- Output grouping: Individually isolated
FAQ
What loads are compatible?
AC loads up to 265V and DC loads up to 125V.
What is the response time?
10 ms maximum for both on and off transitions.
Does it have internal fuses?
No. Use external suppression for inductive loads.
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
Can a Bently Nevada TSI Retrofit Cut False Alarms 71.8%?
This technical guide examines the strategic approach to partial TSI system retrofits for Bently Nevada 3500 series ha...
-
Can Long-Term Vibration Trends Predict Rotating Equipment Fatigue?
Standard PLC and DCS systems often fail to detect progressive mechanical fatigue because they prioritize process vari...
-
How Do PLCs Turn Machine Data Into Proactive Risk Defense?
This article explores how Allen‑Bradley real‑time production monitoring mitigates hidden operational risks in disc...
-
Can Proper HMI Commissioning Really Cut Downtime by 54%?
This article examines the pivotal role of HMI visualization in industrial automation, drawing on field experience wit...
-
Can a Phased Retrofit Cut Your GE Upgrade Costs by Over 50%?
This article examines strategic approaches to modernizing legacy GE PLC and DCS systems in brown‑field industrial sit...
-
How does off-site monitoring cut fault diagnosis time by 79%?
This article examines how GE long-distance data transmission enables off-site centralized monitoring for geographi...
